Cargando…

Microsphere embolisation as an alternative for alcohol in percutaneous transluminal septal myocardial ablation

BACKGROUND: Percutaneous transluminal septal myocardial ablation using microsphere embolisation is a new interventional technique to treat patients with hypertrophic obstructive cardiomyopathy. METHODS AND RESULTS: In two patients, considered at high risk for myectomy, targeted septal perforators we...

Descripción completa

Detalles Bibliográficos
Autores principales: Vriesendorp, P. A., Van Mieghem, N. M., Vletter, W. B., Ten Cate, F. J., de Jong, P. L., Schinkel, A. F. L., Michels, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bohn Stafleu van Loghum 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3636334/
https://www.ncbi.nlm.nih.gov/pubmed/23550029
http://dx.doi.org/10.1007/s12471-013-0393-z
_version_ 1782267319199727616
author Vriesendorp, P. A.
Van Mieghem, N. M.
Vletter, W. B.
Ten Cate, F. J.
de Jong, P. L.
Schinkel, A. F. L.
Michels, M.
author_facet Vriesendorp, P. A.
Van Mieghem, N. M.
Vletter, W. B.
Ten Cate, F. J.
de Jong, P. L.
Schinkel, A. F. L.
Michels, M.
author_sort Vriesendorp, P. A.
collection PubMed
description BACKGROUND: Percutaneous transluminal septal myocardial ablation using microsphere embolisation is a new interventional technique to treat patients with hypertrophic obstructive cardiomyopathy. METHODS AND RESULTS: In two patients, considered at high risk for myectomy, targeted septal perforators were occluded with microsphere embolisation instead of alcohol ablation to reduce left ventricular outflow gradient. In both cases the left ventricular outflow tract gradient was immediately reduced. No adverse events occurred. CONCLUSION: This is the first clinical experience with Embozene® Microspheres in the Netherlands as an alternative for alcohol septal ablation. In both cases it resulted in immediate improvement in the haemodynamics, without any adverse events.
format Online
Article
Text
id pubmed-3636334
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Bohn Stafleu van Loghum
record_format MEDLINE/PubMed
spelling pubmed-36363342013-05-01 Microsphere embolisation as an alternative for alcohol in percutaneous transluminal septal myocardial ablation Vriesendorp, P. A. Van Mieghem, N. M. Vletter, W. B. Ten Cate, F. J. de Jong, P. L. Schinkel, A. F. L. Michels, M. Neth Heart J Special Article BACKGROUND: Percutaneous transluminal septal myocardial ablation using microsphere embolisation is a new interventional technique to treat patients with hypertrophic obstructive cardiomyopathy. METHODS AND RESULTS: In two patients, considered at high risk for myectomy, targeted septal perforators were occluded with microsphere embolisation instead of alcohol ablation to reduce left ventricular outflow gradient. In both cases the left ventricular outflow tract gradient was immediately reduced. No adverse events occurred. CONCLUSION: This is the first clinical experience with Embozene® Microspheres in the Netherlands as an alternative for alcohol septal ablation. In both cases it resulted in immediate improvement in the haemodynamics, without any adverse events. Bohn Stafleu van Loghum 2013-04-03 2013-05 /pmc/articles/PMC3636334/ /pubmed/23550029 http://dx.doi.org/10.1007/s12471-013-0393-z Text en © The Author(s) 2013 https://creativecommons.org/licenses/by-nc/2.0/ Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Special Article
Vriesendorp, P. A.
Van Mieghem, N. M.
Vletter, W. B.
Ten Cate, F. J.
de Jong, P. L.
Schinkel, A. F. L.
Michels, M.
Microsphere embolisation as an alternative for alcohol in percutaneous transluminal septal myocardial ablation
title Microsphere embolisation as an alternative for alcohol in percutaneous transluminal septal myocardial ablation
title_full Microsphere embolisation as an alternative for alcohol in percutaneous transluminal septal myocardial ablation
title_fullStr Microsphere embolisation as an alternative for alcohol in percutaneous transluminal septal myocardial ablation
title_full_unstemmed Microsphere embolisation as an alternative for alcohol in percutaneous transluminal septal myocardial ablation
title_short Microsphere embolisation as an alternative for alcohol in percutaneous transluminal septal myocardial ablation
title_sort microsphere embolisation as an alternative for alcohol in percutaneous transluminal septal myocardial ablation
topic Special Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3636334/
https://www.ncbi.nlm.nih.gov/pubmed/23550029
http://dx.doi.org/10.1007/s12471-013-0393-z
work_keys_str_mv AT vriesendorppa microsphereembolisationasanalternativeforalcoholinpercutaneoustransluminalseptalmyocardialablation
AT vanmieghemnm microsphereembolisationasanalternativeforalcoholinpercutaneoustransluminalseptalmyocardialablation
AT vletterwb microsphereembolisationasanalternativeforalcoholinpercutaneoustransluminalseptalmyocardialablation
AT tencatefj microsphereembolisationasanalternativeforalcoholinpercutaneoustransluminalseptalmyocardialablation
AT dejongpl microsphereembolisationasanalternativeforalcoholinpercutaneoustransluminalseptalmyocardialablation
AT schinkelafl microsphereembolisationasanalternativeforalcoholinpercutaneoustransluminalseptalmyocardialablation
AT michelsm microsphereembolisationasanalternativeforalcoholinpercutaneoustransluminalseptalmyocardialablation