Cargando…
Microsphere embolisation as an alternative for alcohol in percutaneous transluminal septal myocardial ablation
BACKGROUND: Percutaneous transluminal septal myocardial ablation using microsphere embolisation is a new interventional technique to treat patients with hypertrophic obstructive cardiomyopathy. METHODS AND RESULTS: In two patients, considered at high risk for myectomy, targeted septal perforators we...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bohn Stafleu van Loghum
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3636334/ https://www.ncbi.nlm.nih.gov/pubmed/23550029 http://dx.doi.org/10.1007/s12471-013-0393-z |
_version_ | 1782267319199727616 |
---|---|
author | Vriesendorp, P. A. Van Mieghem, N. M. Vletter, W. B. Ten Cate, F. J. de Jong, P. L. Schinkel, A. F. L. Michels, M. |
author_facet | Vriesendorp, P. A. Van Mieghem, N. M. Vletter, W. B. Ten Cate, F. J. de Jong, P. L. Schinkel, A. F. L. Michels, M. |
author_sort | Vriesendorp, P. A. |
collection | PubMed |
description | BACKGROUND: Percutaneous transluminal septal myocardial ablation using microsphere embolisation is a new interventional technique to treat patients with hypertrophic obstructive cardiomyopathy. METHODS AND RESULTS: In two patients, considered at high risk for myectomy, targeted septal perforators were occluded with microsphere embolisation instead of alcohol ablation to reduce left ventricular outflow gradient. In both cases the left ventricular outflow tract gradient was immediately reduced. No adverse events occurred. CONCLUSION: This is the first clinical experience with Embozene® Microspheres in the Netherlands as an alternative for alcohol septal ablation. In both cases it resulted in immediate improvement in the haemodynamics, without any adverse events. |
format | Online Article Text |
id | pubmed-3636334 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Bohn Stafleu van Loghum |
record_format | MEDLINE/PubMed |
spelling | pubmed-36363342013-05-01 Microsphere embolisation as an alternative for alcohol in percutaneous transluminal septal myocardial ablation Vriesendorp, P. A. Van Mieghem, N. M. Vletter, W. B. Ten Cate, F. J. de Jong, P. L. Schinkel, A. F. L. Michels, M. Neth Heart J Special Article BACKGROUND: Percutaneous transluminal septal myocardial ablation using microsphere embolisation is a new interventional technique to treat patients with hypertrophic obstructive cardiomyopathy. METHODS AND RESULTS: In two patients, considered at high risk for myectomy, targeted septal perforators were occluded with microsphere embolisation instead of alcohol ablation to reduce left ventricular outflow gradient. In both cases the left ventricular outflow tract gradient was immediately reduced. No adverse events occurred. CONCLUSION: This is the first clinical experience with Embozene® Microspheres in the Netherlands as an alternative for alcohol septal ablation. In both cases it resulted in immediate improvement in the haemodynamics, without any adverse events. Bohn Stafleu van Loghum 2013-04-03 2013-05 /pmc/articles/PMC3636334/ /pubmed/23550029 http://dx.doi.org/10.1007/s12471-013-0393-z Text en © The Author(s) 2013 https://creativecommons.org/licenses/by-nc/2.0/ Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited. |
spellingShingle | Special Article Vriesendorp, P. A. Van Mieghem, N. M. Vletter, W. B. Ten Cate, F. J. de Jong, P. L. Schinkel, A. F. L. Michels, M. Microsphere embolisation as an alternative for alcohol in percutaneous transluminal septal myocardial ablation |
title | Microsphere embolisation as an alternative for alcohol in percutaneous transluminal septal myocardial ablation |
title_full | Microsphere embolisation as an alternative for alcohol in percutaneous transluminal septal myocardial ablation |
title_fullStr | Microsphere embolisation as an alternative for alcohol in percutaneous transluminal septal myocardial ablation |
title_full_unstemmed | Microsphere embolisation as an alternative for alcohol in percutaneous transluminal septal myocardial ablation |
title_short | Microsphere embolisation as an alternative for alcohol in percutaneous transluminal septal myocardial ablation |
title_sort | microsphere embolisation as an alternative for alcohol in percutaneous transluminal septal myocardial ablation |
topic | Special Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3636334/ https://www.ncbi.nlm.nih.gov/pubmed/23550029 http://dx.doi.org/10.1007/s12471-013-0393-z |
work_keys_str_mv | AT vriesendorppa microsphereembolisationasanalternativeforalcoholinpercutaneoustransluminalseptalmyocardialablation AT vanmieghemnm microsphereembolisationasanalternativeforalcoholinpercutaneoustransluminalseptalmyocardialablation AT vletterwb microsphereembolisationasanalternativeforalcoholinpercutaneoustransluminalseptalmyocardialablation AT tencatefj microsphereembolisationasanalternativeforalcoholinpercutaneoustransluminalseptalmyocardialablation AT dejongpl microsphereembolisationasanalternativeforalcoholinpercutaneoustransluminalseptalmyocardialablation AT schinkelafl microsphereembolisationasanalternativeforalcoholinpercutaneoustransluminalseptalmyocardialablation AT michelsm microsphereembolisationasanalternativeforalcoholinpercutaneoustransluminalseptalmyocardialablation |