Cargando…
Dependence of model-based RSA accuracy on higher and lower implant surface model quality
BACKGROUND: Model-based Roentgen Stereophotogrammetric Analysis (MBRSA) allows the accurate in vivo measurement of the relative motion between an implant and the surrounding bone (migration), using pose-estimation algorithms and three dimensional geometric surface models of the implant. The goal of...
Autores principales: | Seehaus, Frank, Emmerich, Judith, Kaptein, Bart L, Windhagen, Henning, Hurschler, Christof |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3637620/ https://www.ncbi.nlm.nih.gov/pubmed/23587251 http://dx.doi.org/10.1186/1475-925X-12-32 |
Ejemplares similares
-
Greater early migration of a short-stem total hip arthroplasty is not associated with an increased risk of osseointegration failure: 5th-year results from a prospective RSA study with 39 patients, a follow-up study
por: Floerkemeier, Thilo, et al.
Publicado: (2020) -
Effects of unstable footwear on joint reactions and muscle forces: an inverse dynamics study
por: Schwarze, Michael, et al.
Publicado: (2012) -
The prevalence of osteoarthritis: Higher risk after transfemoral amputation?—A database analysis with 1,569 amputees and matched controls
por: Welke, Bastian, et al.
Publicado: (2019) -
A model-based radiostereometric analysis (RSA) randomized control trial evaluating the stability of the cementless Taperloc hip stem: the TapHip study 2-year follow-up RSA and PROMs results
por: KOK, Ruben Y, et al.
Publicado: (2022) -
Changes in Strain Patterns After Implantation of a Short Stem With Metaphyseal Anchorage Compared to a Standard Stem: An Experimental Study in Synthetic Bone
por: Gronewold, Jens, et al.
Publicado: (2014)