Fatal Septic Internal Jugular Vein-Sigmoid Sinus Thrombosis Associated with a Malpositioned Central Venous Catheter
Septic internal jugular vein-sigmoid sinus thrombosis (IJV-SST) associated with a malpositioned central venous catheter is a rare condition. It is potentially life-threatening and necessitates early diagnosis and rapid administration of appropriate medications. Unfortunately, it is difficult to diag...