Cargando…
On-Chip Cryopreservation: A Novel Method for Ultra-Rapid Cryoprotectant-Free Cryopreservation of Small Amounts of Human Spermatozoa
Cryopreservation of human spermatozoa free from cryoprotectant can avoid toxicity caused by highly concentrated cryoprotectant and a series of specific carriers have been previously explored, except for PDMS chip. Our study is aimed at exploring a novel device for ultra-rapid cryopreservation of sma...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3640000/ https://www.ncbi.nlm.nih.gov/pubmed/23646110 http://dx.doi.org/10.1371/journal.pone.0061593 |
_version_ | 1782476036706926592 |
---|---|
author | Zou, Yujie Yin, Tailang Chen, Shijing Yang, Jing Huang, Weihua |
author_facet | Zou, Yujie Yin, Tailang Chen, Shijing Yang, Jing Huang, Weihua |
author_sort | Zou, Yujie |
collection | PubMed |
description | Cryopreservation of human spermatozoa free from cryoprotectant can avoid toxicity caused by highly concentrated cryoprotectant and a series of specific carriers have been previously explored, except for PDMS chip. Our study is aimed at exploring a novel device for ultra-rapid cryopreservation of small numbers of spermatozoa without cryoprotectant based on polydimethylsiloxane (PDMS) chips. Spermatozoa from 25 healthy men were involved in this study, comparing on-chip cryopreservation with different micro-channel height (group A: 10 µm height, group B: 50 µm height, group C: 100 µm height) and conventional freezing (group D) in liquid nitrogen for 72 h. The viability, motility, DNA integrity by comet assay and acrosome integrity by fluorescein isothiocyanate-conjugated peanut agglutinin (FITC-PNA) staining of frozen-thawed spermatozoa of each group were compared. The motility and viability of post-thawed spermatozoa was significantly decreased than that of pre-freezing spermatozoa. There was no difference of viability and motility of frozen-thawed spermatozoa between group A and D, while viability and motility of group B and C decreased compared to group A. Comet assay showed that no matter for group A or D, there was no difference of CR, TL, TD and OTM between pre-frozen and post-thawed spermatozoa. There was no difference of CR, TL, TD and OTM of post-thawed spermatozoa between group A and group D neither, while spermatozoa DNA damage was more serious in group B and group C with increasing height of micro-channel compared with group A. The proportion of intact acrosome of post-thawed spermatozoa in group A was the highest when compared with group B and group C, though similar to that of group D. In conclusion, PDMS chip with 10 µm height micro-channel is ideal for ultra-rapid cryopreservation of small quantity of spermatozoa without cryoprotectant. |
format | Online Article Text |
id | pubmed-3640000 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-36400002013-05-03 On-Chip Cryopreservation: A Novel Method for Ultra-Rapid Cryoprotectant-Free Cryopreservation of Small Amounts of Human Spermatozoa Zou, Yujie Yin, Tailang Chen, Shijing Yang, Jing Huang, Weihua PLoS One Research Article Cryopreservation of human spermatozoa free from cryoprotectant can avoid toxicity caused by highly concentrated cryoprotectant and a series of specific carriers have been previously explored, except for PDMS chip. Our study is aimed at exploring a novel device for ultra-rapid cryopreservation of small numbers of spermatozoa without cryoprotectant based on polydimethylsiloxane (PDMS) chips. Spermatozoa from 25 healthy men were involved in this study, comparing on-chip cryopreservation with different micro-channel height (group A: 10 µm height, group B: 50 µm height, group C: 100 µm height) and conventional freezing (group D) in liquid nitrogen for 72 h. The viability, motility, DNA integrity by comet assay and acrosome integrity by fluorescein isothiocyanate-conjugated peanut agglutinin (FITC-PNA) staining of frozen-thawed spermatozoa of each group were compared. The motility and viability of post-thawed spermatozoa was significantly decreased than that of pre-freezing spermatozoa. There was no difference of viability and motility of frozen-thawed spermatozoa between group A and D, while viability and motility of group B and C decreased compared to group A. Comet assay showed that no matter for group A or D, there was no difference of CR, TL, TD and OTM between pre-frozen and post-thawed spermatozoa. There was no difference of CR, TL, TD and OTM of post-thawed spermatozoa between group A and group D neither, while spermatozoa DNA damage was more serious in group B and group C with increasing height of micro-channel compared with group A. The proportion of intact acrosome of post-thawed spermatozoa in group A was the highest when compared with group B and group C, though similar to that of group D. In conclusion, PDMS chip with 10 µm height micro-channel is ideal for ultra-rapid cryopreservation of small quantity of spermatozoa without cryoprotectant. Public Library of Science 2013-04-30 /pmc/articles/PMC3640000/ /pubmed/23646110 http://dx.doi.org/10.1371/journal.pone.0061593 Text en © 2013 Zou et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Zou, Yujie Yin, Tailang Chen, Shijing Yang, Jing Huang, Weihua On-Chip Cryopreservation: A Novel Method for Ultra-Rapid Cryoprotectant-Free Cryopreservation of Small Amounts of Human Spermatozoa |
title | On-Chip Cryopreservation: A Novel Method for Ultra-Rapid Cryoprotectant-Free Cryopreservation of Small Amounts of Human Spermatozoa |
title_full | On-Chip Cryopreservation: A Novel Method for Ultra-Rapid Cryoprotectant-Free Cryopreservation of Small Amounts of Human Spermatozoa |
title_fullStr | On-Chip Cryopreservation: A Novel Method for Ultra-Rapid Cryoprotectant-Free Cryopreservation of Small Amounts of Human Spermatozoa |
title_full_unstemmed | On-Chip Cryopreservation: A Novel Method for Ultra-Rapid Cryoprotectant-Free Cryopreservation of Small Amounts of Human Spermatozoa |
title_short | On-Chip Cryopreservation: A Novel Method for Ultra-Rapid Cryoprotectant-Free Cryopreservation of Small Amounts of Human Spermatozoa |
title_sort | on-chip cryopreservation: a novel method for ultra-rapid cryoprotectant-free cryopreservation of small amounts of human spermatozoa |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3640000/ https://www.ncbi.nlm.nih.gov/pubmed/23646110 http://dx.doi.org/10.1371/journal.pone.0061593 |
work_keys_str_mv | AT zouyujie onchipcryopreservationanovelmethodforultrarapidcryoprotectantfreecryopreservationofsmallamountsofhumanspermatozoa AT yintailang onchipcryopreservationanovelmethodforultrarapidcryoprotectantfreecryopreservationofsmallamountsofhumanspermatozoa AT chenshijing onchipcryopreservationanovelmethodforultrarapidcryoprotectantfreecryopreservationofsmallamountsofhumanspermatozoa AT yangjing onchipcryopreservationanovelmethodforultrarapidcryoprotectantfreecryopreservationofsmallamountsofhumanspermatozoa AT huangweihua onchipcryopreservationanovelmethodforultrarapidcryoprotectantfreecryopreservationofsmallamountsofhumanspermatozoa |