Cargando…
Simultaneous Analysis and Quality Assurance for Diffusion Tensor Imaging
Diffusion tensor imaging (DTI) enables non-invasive, cyto-architectural mapping of in vivo tissue microarchitecture through voxel-wise mathematical modeling of multiple magnetic resonance imaging (MRI) acquisitions, each differently sensitized to water diffusion. DTI computations are fundamentally e...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3640065/ https://www.ncbi.nlm.nih.gov/pubmed/23637895 http://dx.doi.org/10.1371/journal.pone.0061737 |
_version_ | 1782476051526451200 |
---|---|
author | Lauzon, Carolyn B. Asman, Andrew J. Esparza, Michael L. Burns, Scott S. Fan, Qiuyun Gao, Yurui Anderson, Adam W. Davis, Nicole Cutting, Laurie E. Landman, Bennett A. |
author_facet | Lauzon, Carolyn B. Asman, Andrew J. Esparza, Michael L. Burns, Scott S. Fan, Qiuyun Gao, Yurui Anderson, Adam W. Davis, Nicole Cutting, Laurie E. Landman, Bennett A. |
author_sort | Lauzon, Carolyn B. |
collection | PubMed |
description | Diffusion tensor imaging (DTI) enables non-invasive, cyto-architectural mapping of in vivo tissue microarchitecture through voxel-wise mathematical modeling of multiple magnetic resonance imaging (MRI) acquisitions, each differently sensitized to water diffusion. DTI computations are fundamentally estimation processes and are sensitive to noise and artifacts. Despite widespread adoption in the neuroimaging community, maintaining consistent DTI data quality remains challenging given the propensity for patient motion, artifacts associated with fast imaging techniques, and the possibility of hardware changes/failures. Furthermore, the quantity of data acquired per voxel, the non-linear estimation process, and numerous potential use cases complicate traditional visual data inspection approaches. Currently, quality inspection of DTI data has relied on visual inspection and individual processing in DTI analysis software programs (e.g. DTIPrep, DTI-studio). However, recent advances in applied statistical methods have yielded several different metrics to assess noise level, artifact propensity, quality of tensor fit, variance of estimated measures, and bias in estimated measures. To date, these metrics have been largely studied in isolation. Herein, we select complementary metrics for integration into an automatic DTI analysis and quality assurance pipeline. The pipeline completes in 24 hours, stores statistical outputs, and produces a graphical summary quality analysis (QA) report. We assess the utility of this streamlined approach for empirical quality assessment on 608 DTI datasets from pediatric neuroimaging studies. The efficiency and accuracy of quality analysis using the proposed pipeline is compared with quality analysis based on visual inspection. The unified pipeline is found to save a statistically significant amount of time (over 70%) while improving the consistency of QA between a DTI expert and a pool of research associates. Projection of QA metrics to a low dimensional manifold reveal qualitative, but clear, QA-study associations and suggest that automated outlier/anomaly detection would be feasible. |
format | Online Article Text |
id | pubmed-3640065 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-36400652013-05-01 Simultaneous Analysis and Quality Assurance for Diffusion Tensor Imaging Lauzon, Carolyn B. Asman, Andrew J. Esparza, Michael L. Burns, Scott S. Fan, Qiuyun Gao, Yurui Anderson, Adam W. Davis, Nicole Cutting, Laurie E. Landman, Bennett A. PLoS One Research Article Diffusion tensor imaging (DTI) enables non-invasive, cyto-architectural mapping of in vivo tissue microarchitecture through voxel-wise mathematical modeling of multiple magnetic resonance imaging (MRI) acquisitions, each differently sensitized to water diffusion. DTI computations are fundamentally estimation processes and are sensitive to noise and artifacts. Despite widespread adoption in the neuroimaging community, maintaining consistent DTI data quality remains challenging given the propensity for patient motion, artifacts associated with fast imaging techniques, and the possibility of hardware changes/failures. Furthermore, the quantity of data acquired per voxel, the non-linear estimation process, and numerous potential use cases complicate traditional visual data inspection approaches. Currently, quality inspection of DTI data has relied on visual inspection and individual processing in DTI analysis software programs (e.g. DTIPrep, DTI-studio). However, recent advances in applied statistical methods have yielded several different metrics to assess noise level, artifact propensity, quality of tensor fit, variance of estimated measures, and bias in estimated measures. To date, these metrics have been largely studied in isolation. Herein, we select complementary metrics for integration into an automatic DTI analysis and quality assurance pipeline. The pipeline completes in 24 hours, stores statistical outputs, and produces a graphical summary quality analysis (QA) report. We assess the utility of this streamlined approach for empirical quality assessment on 608 DTI datasets from pediatric neuroimaging studies. The efficiency and accuracy of quality analysis using the proposed pipeline is compared with quality analysis based on visual inspection. The unified pipeline is found to save a statistically significant amount of time (over 70%) while improving the consistency of QA between a DTI expert and a pool of research associates. Projection of QA metrics to a low dimensional manifold reveal qualitative, but clear, QA-study associations and suggest that automated outlier/anomaly detection would be feasible. Public Library of Science 2013-04-30 /pmc/articles/PMC3640065/ /pubmed/23637895 http://dx.doi.org/10.1371/journal.pone.0061737 Text en © 2013 Lauzon http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Lauzon, Carolyn B. Asman, Andrew J. Esparza, Michael L. Burns, Scott S. Fan, Qiuyun Gao, Yurui Anderson, Adam W. Davis, Nicole Cutting, Laurie E. Landman, Bennett A. Simultaneous Analysis and Quality Assurance for Diffusion Tensor Imaging |
title | Simultaneous Analysis and Quality Assurance for Diffusion Tensor Imaging |
title_full | Simultaneous Analysis and Quality Assurance for Diffusion Tensor Imaging |
title_fullStr | Simultaneous Analysis and Quality Assurance for Diffusion Tensor Imaging |
title_full_unstemmed | Simultaneous Analysis and Quality Assurance for Diffusion Tensor Imaging |
title_short | Simultaneous Analysis and Quality Assurance for Diffusion Tensor Imaging |
title_sort | simultaneous analysis and quality assurance for diffusion tensor imaging |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3640065/ https://www.ncbi.nlm.nih.gov/pubmed/23637895 http://dx.doi.org/10.1371/journal.pone.0061737 |
work_keys_str_mv | AT lauzoncarolynb simultaneousanalysisandqualityassurancefordiffusiontensorimaging AT asmanandrewj simultaneousanalysisandqualityassurancefordiffusiontensorimaging AT esparzamichaell simultaneousanalysisandqualityassurancefordiffusiontensorimaging AT burnsscotts simultaneousanalysisandqualityassurancefordiffusiontensorimaging AT fanqiuyun simultaneousanalysisandqualityassurancefordiffusiontensorimaging AT gaoyurui simultaneousanalysisandqualityassurancefordiffusiontensorimaging AT andersonadamw simultaneousanalysisandqualityassurancefordiffusiontensorimaging AT davisnicole simultaneousanalysisandqualityassurancefordiffusiontensorimaging AT cuttinglauriee simultaneousanalysisandqualityassurancefordiffusiontensorimaging AT landmanbennetta simultaneousanalysisandqualityassurancefordiffusiontensorimaging |