Cargando…

Volumetric three-dimensional intravascular ultrasound visualization using shape-based nonlinear interpolation

BACKGROUND: Intravascular ultrasound (IVUS) is a standard imaging modality for identification of plaque formation in the coronary and peripheral arteries. Volumetric three-dimensional (3D) IVUS visualization provides a powerful tool to overcome the limited comprehensive information of 2D IVUS in ter...

Descripción completa

Detalles Bibliográficos
Autores principales: Rim, Yonghoon, McPherson, David D, Kim, Hyunggun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3651297/
https://www.ncbi.nlm.nih.gov/pubmed/23651569
http://dx.doi.org/10.1186/1475-925X-12-39
_version_ 1782269199051128832
author Rim, Yonghoon
McPherson, David D
Kim, Hyunggun
author_facet Rim, Yonghoon
McPherson, David D
Kim, Hyunggun
author_sort Rim, Yonghoon
collection PubMed
description BACKGROUND: Intravascular ultrasound (IVUS) is a standard imaging modality for identification of plaque formation in the coronary and peripheral arteries. Volumetric three-dimensional (3D) IVUS visualization provides a powerful tool to overcome the limited comprehensive information of 2D IVUS in terms of complex spatial distribution of arterial morphology and acoustic backscatter information. Conventional 3D IVUS techniques provide sub-optimal visualization of arterial morphology or lack acoustic information concerning arterial structure due in part to low quality of image data and the use of pixel-based IVUS image reconstruction algorithms. In the present study, we describe a novel volumetric 3D IVUS reconstruction algorithm to utilize IVUS signal data and a shape-based nonlinear interpolation. METHODS: We developed an algorithm to convert a series of IVUS signal data into a fully volumetric 3D visualization. Intermediary slices between original 2D IVUS slices were generated utilizing the natural cubic spline interpolation to consider the nonlinearity of both vascular structure geometry and acoustic backscatter in the arterial wall. We evaluated differences in image quality between the conventional pixel-based interpolation and the shape-based nonlinear interpolation methods using both virtual vascular phantom data and in vivo IVUS data of a porcine femoral artery. Volumetric 3D IVUS images of the arterial segment reconstructed using the two interpolation methods were compared. RESULTS: In vitro validation and in vivo comparative studies with the conventional pixel-based interpolation method demonstrated more robustness of the shape-based nonlinear interpolation algorithm in determining intermediary 2D IVUS slices. Our shape-based nonlinear interpolation demonstrated improved volumetric 3D visualization of the in vivo arterial structure and more realistic acoustic backscatter distribution compared to the conventional pixel-based interpolation method. CONCLUSIONS: This novel 3D IVUS visualization strategy has the potential to improve ultrasound imaging of vascular structure information, particularly atheroma determination. Improved volumetric 3D visualization with accurate acoustic backscatter information can help with ultrasound molecular imaging of atheroma component distribution.
format Online
Article
Text
id pubmed-3651297
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-36512972013-05-14 Volumetric three-dimensional intravascular ultrasound visualization using shape-based nonlinear interpolation Rim, Yonghoon McPherson, David D Kim, Hyunggun Biomed Eng Online Research BACKGROUND: Intravascular ultrasound (IVUS) is a standard imaging modality for identification of plaque formation in the coronary and peripheral arteries. Volumetric three-dimensional (3D) IVUS visualization provides a powerful tool to overcome the limited comprehensive information of 2D IVUS in terms of complex spatial distribution of arterial morphology and acoustic backscatter information. Conventional 3D IVUS techniques provide sub-optimal visualization of arterial morphology or lack acoustic information concerning arterial structure due in part to low quality of image data and the use of pixel-based IVUS image reconstruction algorithms. In the present study, we describe a novel volumetric 3D IVUS reconstruction algorithm to utilize IVUS signal data and a shape-based nonlinear interpolation. METHODS: We developed an algorithm to convert a series of IVUS signal data into a fully volumetric 3D visualization. Intermediary slices between original 2D IVUS slices were generated utilizing the natural cubic spline interpolation to consider the nonlinearity of both vascular structure geometry and acoustic backscatter in the arterial wall. We evaluated differences in image quality between the conventional pixel-based interpolation and the shape-based nonlinear interpolation methods using both virtual vascular phantom data and in vivo IVUS data of a porcine femoral artery. Volumetric 3D IVUS images of the arterial segment reconstructed using the two interpolation methods were compared. RESULTS: In vitro validation and in vivo comparative studies with the conventional pixel-based interpolation method demonstrated more robustness of the shape-based nonlinear interpolation algorithm in determining intermediary 2D IVUS slices. Our shape-based nonlinear interpolation demonstrated improved volumetric 3D visualization of the in vivo arterial structure and more realistic acoustic backscatter distribution compared to the conventional pixel-based interpolation method. CONCLUSIONS: This novel 3D IVUS visualization strategy has the potential to improve ultrasound imaging of vascular structure information, particularly atheroma determination. Improved volumetric 3D visualization with accurate acoustic backscatter information can help with ultrasound molecular imaging of atheroma component distribution. BioMed Central 2013-05-07 /pmc/articles/PMC3651297/ /pubmed/23651569 http://dx.doi.org/10.1186/1475-925X-12-39 Text en Copyright © 2013 Rim et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Rim, Yonghoon
McPherson, David D
Kim, Hyunggun
Volumetric three-dimensional intravascular ultrasound visualization using shape-based nonlinear interpolation
title Volumetric three-dimensional intravascular ultrasound visualization using shape-based nonlinear interpolation
title_full Volumetric three-dimensional intravascular ultrasound visualization using shape-based nonlinear interpolation
title_fullStr Volumetric three-dimensional intravascular ultrasound visualization using shape-based nonlinear interpolation
title_full_unstemmed Volumetric three-dimensional intravascular ultrasound visualization using shape-based nonlinear interpolation
title_short Volumetric three-dimensional intravascular ultrasound visualization using shape-based nonlinear interpolation
title_sort volumetric three-dimensional intravascular ultrasound visualization using shape-based nonlinear interpolation
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3651297/
https://www.ncbi.nlm.nih.gov/pubmed/23651569
http://dx.doi.org/10.1186/1475-925X-12-39
work_keys_str_mv AT rimyonghoon volumetricthreedimensionalintravascularultrasoundvisualizationusingshapebasednonlinearinterpolation
AT mcphersondavidd volumetricthreedimensionalintravascularultrasoundvisualizationusingshapebasednonlinearinterpolation
AT kimhyunggun volumetricthreedimensionalintravascularultrasoundvisualizationusingshapebasednonlinearinterpolation