Dense Array EEG Source Estimation in Neocortical Epilepsy

Rationale: Dense array EEG (dEEG) evenly covers the whole head surface with over 100 channels contributing to more accurate electrical source imaging due to the higher spatial and temporal resolution. Several studies have shown the clinical utility of dEEG in presurgical clinical evaluation of epile...

Descripción completa

Detalles Bibliográficos
Autores principales: Yamazaki, Madoka, Tucker, Don M., Terrill, Marie, Fujimoto, Ayataka, Yamamoto, Takamichi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3652005/
https://www.ncbi.nlm.nih.gov/pubmed/23717298
http://dx.doi.org/10.3389/fneur.2013.00042
_version_ 1782269260887752704
author Yamazaki, Madoka
Tucker, Don M.
Terrill, Marie
Fujimoto, Ayataka
Yamamoto, Takamichi
author_facet Yamazaki, Madoka
Tucker, Don M.
Terrill, Marie
Fujimoto, Ayataka
Yamamoto, Takamichi
author_sort Yamazaki, Madoka
collection PubMed
description Rationale: Dense array EEG (dEEG) evenly covers the whole head surface with over 100 channels contributing to more accurate electrical source imaging due to the higher spatial and temporal resolution. Several studies have shown the clinical utility of dEEG in presurgical clinical evaluation of epilepsy. However validation studies measuring the accuracy of dEEG source imaging are still needed. This can be achieved through simultaneously recording both scalp dEEG with intracranial electrodes (icEEG), which is considered as the true measure of cortical activity at the source. The purpose of this study is to evaluate the accuracy of 256-channel dEEG electrical source estimation for interictal spikes. Methods: Four patients with medically refractory neocortical epilepsy, all surgical candidates, underwent subdural electrode implantation to determine ictal onset and define functional areas. One patient showed a lesion on the magnetic resonance imaging in the right parietal lobe. The patient underwent simultaneous recording of interictal spikes by both scalp 256-channelsvdEEG and icEEG. The dEEG was used to non-invasively estimate the source of the interictal spikes detected by the 256-channel dEEG array, which was then compared to the activity measured directly at the source by the icEEG. Results: From the four patients, a total of 287 interictal spikes were measured with the icEEG. One hundred fifty-five of the 287 spikes (54%) were visually detected by the dEEG upon examination of the 256 channel head surface array. The spike amplitudes detected by the 256-channel dEEG correlated with icEEG spike amplitudes (p < 0.01). All spikes detected in dEEG were localized to the same lobe correctly. Conclusion: Our study demonstrates that 256-channel dEEG can reliably detect interictal spikes and localize them with reasonable accuracy. Two hundred fifty-six-channel dEEG may be clinically useful in the presurgical workup for epilepsy and also reduce the need for invasive EEG evaluation.
format Online
Article
Text
id pubmed-3652005
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-36520052013-05-28 Dense Array EEG Source Estimation in Neocortical Epilepsy Yamazaki, Madoka Tucker, Don M. Terrill, Marie Fujimoto, Ayataka Yamamoto, Takamichi Front Neurol Neuroscience Rationale: Dense array EEG (dEEG) evenly covers the whole head surface with over 100 channels contributing to more accurate electrical source imaging due to the higher spatial and temporal resolution. Several studies have shown the clinical utility of dEEG in presurgical clinical evaluation of epilepsy. However validation studies measuring the accuracy of dEEG source imaging are still needed. This can be achieved through simultaneously recording both scalp dEEG with intracranial electrodes (icEEG), which is considered as the true measure of cortical activity at the source. The purpose of this study is to evaluate the accuracy of 256-channel dEEG electrical source estimation for interictal spikes. Methods: Four patients with medically refractory neocortical epilepsy, all surgical candidates, underwent subdural electrode implantation to determine ictal onset and define functional areas. One patient showed a lesion on the magnetic resonance imaging in the right parietal lobe. The patient underwent simultaneous recording of interictal spikes by both scalp 256-channelsvdEEG and icEEG. The dEEG was used to non-invasively estimate the source of the interictal spikes detected by the 256-channel dEEG array, which was then compared to the activity measured directly at the source by the icEEG. Results: From the four patients, a total of 287 interictal spikes were measured with the icEEG. One hundred fifty-five of the 287 spikes (54%) were visually detected by the dEEG upon examination of the 256 channel head surface array. The spike amplitudes detected by the 256-channel dEEG correlated with icEEG spike amplitudes (p < 0.01). All spikes detected in dEEG were localized to the same lobe correctly. Conclusion: Our study demonstrates that 256-channel dEEG can reliably detect interictal spikes and localize them with reasonable accuracy. Two hundred fifty-six-channel dEEG may be clinically useful in the presurgical workup for epilepsy and also reduce the need for invasive EEG evaluation. Frontiers Media S.A. 2013-05-13 /pmc/articles/PMC3652005/ /pubmed/23717298 http://dx.doi.org/10.3389/fneur.2013.00042 Text en Copyright © 2013 Yamazaki, Tucker, Terrill, Fujimoto and Yamamoto. http://creativecommons.org/licenses/by/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in other forums, provided the original authors and source are credited and subject to any copyright notices concerning any third-party graphics etc.
spellingShingle Neuroscience
Yamazaki, Madoka
Tucker, Don M.
Terrill, Marie
Fujimoto, Ayataka
Yamamoto, Takamichi
Dense Array EEG Source Estimation in Neocortical Epilepsy
title Dense Array EEG Source Estimation in Neocortical Epilepsy
title_full Dense Array EEG Source Estimation in Neocortical Epilepsy
title_fullStr Dense Array EEG Source Estimation in Neocortical Epilepsy
title_full_unstemmed Dense Array EEG Source Estimation in Neocortical Epilepsy
title_short Dense Array EEG Source Estimation in Neocortical Epilepsy
title_sort dense array eeg source estimation in neocortical epilepsy
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3652005/
https://www.ncbi.nlm.nih.gov/pubmed/23717298
http://dx.doi.org/10.3389/fneur.2013.00042
work_keys_str_mv AT yamazakimadoka densearrayeegsourceestimationinneocorticalepilepsy
AT tuckerdonm densearrayeegsourceestimationinneocorticalepilepsy
AT terrillmarie densearrayeegsourceestimationinneocorticalepilepsy
AT fujimotoayataka densearrayeegsourceestimationinneocorticalepilepsy
AT yamamototakamichi densearrayeegsourceestimationinneocorticalepilepsy