Evaluation and comparison of New 4DCT based strategies for proton treatment planning for lung tumors
PURPOSE: To evaluate different strategies for proton lung treatment planning based on four-dimensional CT (4DCT) scans. METHODS AND MATERIALS: Twelve cases, involving only gross tumor volumes (GTV), were evaluated. Single image sets of (1) maximum intensity projection (MIP3) of end inhale (EI), midd...