Cargando…

Single-platform, volumetric, CD45-assisted pan-leucogating flow cytometry for CD4 T lymphocytes monitoring of HIV infection according to the WHO recommendations for resource-constrained settings

BACKGROUND: Validation of new affordable CD4 T cell measurement technologies is crucial specifically in resource-poor countries for antiretroviral treatment eligibility and immunologic CD4 monitoring of HIV-infected patients. METHODS: The absolute and percentage CD4 T cell counts of 258 HIV-1-infect...

Descripción completa

Detalles Bibliográficos
Autores principales: Koyalta, Donato, Jenabian, Mohammad-Ali, Nadjiouroum, Ngamasra, Djouater, Barou, Djemadji-Oudjeil, Noël, Ndjoyi-Mbiguino, Angélique, Bélec, Laurent
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3653683/
https://www.ncbi.nlm.nih.gov/pubmed/23631664
http://dx.doi.org/10.1186/1756-0500-6-169
Descripción
Sumario:BACKGROUND: Validation of new affordable CD4 T cell measurement technologies is crucial specifically in resource-poor countries for antiretroviral treatment eligibility and immunologic CD4 monitoring of HIV-infected patients. METHODS: The absolute and percentage CD4 T cell counts of 258 HIV-1-infected blood samples (182 adults and 76 children), living in N’Djamena, Chad, were performed by single-platform, volumetric, CD45-assisted pan-leucogating Auto40 flow cytometer (Apogee Flow Systems Ltd, Hemel Hempstead, UK) comparing to the FACSCalibur flow cytometer as a reference method. RESULTS: Absolute and percentage CD4 T cell counts obtained by Auto40 and FACSCalibur of 258 HIV-1-infected blood samples were highly correlated (r = 0.99 and r = 0.96, respectively). The mean absolute bias and percent bias between Apogee Auto40 and FACSCalibur absolute CD4 T cell counts, were −9.4 cells/μl with limits of agreement from −15 to 93 cells/μl, and +2.0% with limits of agreement from −0.9 to 4.9%, respectively. The mean of absolute bias and percent bias between Apogee Auto40 and FACSCalibur of CD4 percentage results were +0.4% (95% CI: -0.02 – 0.86) with limits of agreement from −2.4 to 0.3%, and +3.0% with limits of agreement from −6.6 to 0.6%, respectively. The Auto40 counting allowed to identify the majority of adults with CD4 T cells below 200 cells/μl (sensitivity: 89%; specificity: 99%) or below 350 cells/μl (sensitivity: 94%; specificity:98%); and of children below 750 cells/μl (sensitivity: 99%; specificity: 96%) or below 25% CD4+ (sensitivity: 94%; specificity: 98%). CONCLUSION: The Auto40 analyzer is an alternative flow cytometer for CD4 T lymphocyte enumeration to be used in routine for immunological monitoring according to the current WHO recommendations in HIV-infected adults as well as children living in resource-constrained settings like Chad.