Cargando…

Dual Switching Monopolar Radiofrequency Ablation Using a Separable Clustered Electrode: Comparison with Consecutive and Switching Monopolar Modes in Ex Vivo Bovine Livers

OBJECTIVE: To compare the in-vitro efficiency of dual-switching monopolar (DSM) radiofrequency ablation (RFA) using a separable clustered electrode (Octopus® electrodes) with consecutive monopolar (CM) and switching monopolar (SM) RFA techniques to create an ablative zone in the explanted bovine liv...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoon, Jeong-Hee, Lee, Jeong Min, Han, Joon Koo, Choi, Byung Ihn
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3655292/
https://www.ncbi.nlm.nih.gov/pubmed/23690705
http://dx.doi.org/10.3348/kjr.2013.14.3.403
_version_ 1782269864260403200
author Yoon, Jeong-Hee
Lee, Jeong Min
Han, Joon Koo
Choi, Byung Ihn
author_facet Yoon, Jeong-Hee
Lee, Jeong Min
Han, Joon Koo
Choi, Byung Ihn
author_sort Yoon, Jeong-Hee
collection PubMed
description OBJECTIVE: To compare the in-vitro efficiency of dual-switching monopolar (DSM) radiofrequency ablation (RFA) using a separable clustered electrode (Octopus® electrodes) with consecutive monopolar (CM) and switching monopolar (SM) RFA techniques to create an ablative zone in the explanted bovine liver. MATERIALS AND METHODS: For DSM-RFA, we used a prototype, three-channel, dual generator RFA Unit and Octopus® electrodes with three, 17 gauge internally cooled electrodes. The RFA Unit allowed simultaneous radiofrequency (RF) energy delivery to two electrodes of the Octopus® electrodes as well as automatic switching among the three electrode pairs according to the impedance changes. RF energy was sequentially applied to one of the three electrodes for 24 minutes (group A; CM mode, n = 10) or alternatively applied for 12 minutes (group B; SM mode, n = 10) or concurrently applied to a pair of electrodes for 12 minutes (group C; DSM mode, n = 10) in explanted bovine livers. Changes in the impedance and current during RFA as well as the dimensions of the thermal ablative zones were compared among the three groups. RESULTS: The mean, delivered RF energy amounts in groups A, B, and C were 63.15 ± 8.6 kJ, 72.13 ± 5.4 kJ, and 106.08 ± 13.4 kJ, respectively (p < 0.001). The DSM mode created a significantly larger ablation volume than did the other modes, i.e., 68.1 ± 10.2 cm(3) (group A), 92.0 ± 19.9 cm(3) (group B), and 115.1 ± 14.0 cm(3) (group C) (p < 0.001). The circularity in groups A, B, and C were 0.84 ± 0.06, 0.87 ± 0.04 and 0.90 ± 0.03, respectively (p = 0.03). CONCLUSION: DSM-RFA using Octopus® electrodes can help create large ablative zones within a relatively short time.
format Online
Article
Text
id pubmed-3655292
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-36552922013-05-20 Dual Switching Monopolar Radiofrequency Ablation Using a Separable Clustered Electrode: Comparison with Consecutive and Switching Monopolar Modes in Ex Vivo Bovine Livers Yoon, Jeong-Hee Lee, Jeong Min Han, Joon Koo Choi, Byung Ihn Korean J Radiol Gastrointestinal Imaging OBJECTIVE: To compare the in-vitro efficiency of dual-switching monopolar (DSM) radiofrequency ablation (RFA) using a separable clustered electrode (Octopus® electrodes) with consecutive monopolar (CM) and switching monopolar (SM) RFA techniques to create an ablative zone in the explanted bovine liver. MATERIALS AND METHODS: For DSM-RFA, we used a prototype, three-channel, dual generator RFA Unit and Octopus® electrodes with three, 17 gauge internally cooled electrodes. The RFA Unit allowed simultaneous radiofrequency (RF) energy delivery to two electrodes of the Octopus® electrodes as well as automatic switching among the three electrode pairs according to the impedance changes. RF energy was sequentially applied to one of the three electrodes for 24 minutes (group A; CM mode, n = 10) or alternatively applied for 12 minutes (group B; SM mode, n = 10) or concurrently applied to a pair of electrodes for 12 minutes (group C; DSM mode, n = 10) in explanted bovine livers. Changes in the impedance and current during RFA as well as the dimensions of the thermal ablative zones were compared among the three groups. RESULTS: The mean, delivered RF energy amounts in groups A, B, and C were 63.15 ± 8.6 kJ, 72.13 ± 5.4 kJ, and 106.08 ± 13.4 kJ, respectively (p < 0.001). The DSM mode created a significantly larger ablation volume than did the other modes, i.e., 68.1 ± 10.2 cm(3) (group A), 92.0 ± 19.9 cm(3) (group B), and 115.1 ± 14.0 cm(3) (group C) (p < 0.001). The circularity in groups A, B, and C were 0.84 ± 0.06, 0.87 ± 0.04 and 0.90 ± 0.03, respectively (p = 0.03). CONCLUSION: DSM-RFA using Octopus® electrodes can help create large ablative zones within a relatively short time. The Korean Society of Radiology 2013 2013-05-02 /pmc/articles/PMC3655292/ /pubmed/23690705 http://dx.doi.org/10.3348/kjr.2013.14.3.403 Text en Copyright © 2013 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Gastrointestinal Imaging
Yoon, Jeong-Hee
Lee, Jeong Min
Han, Joon Koo
Choi, Byung Ihn
Dual Switching Monopolar Radiofrequency Ablation Using a Separable Clustered Electrode: Comparison with Consecutive and Switching Monopolar Modes in Ex Vivo Bovine Livers
title Dual Switching Monopolar Radiofrequency Ablation Using a Separable Clustered Electrode: Comparison with Consecutive and Switching Monopolar Modes in Ex Vivo Bovine Livers
title_full Dual Switching Monopolar Radiofrequency Ablation Using a Separable Clustered Electrode: Comparison with Consecutive and Switching Monopolar Modes in Ex Vivo Bovine Livers
title_fullStr Dual Switching Monopolar Radiofrequency Ablation Using a Separable Clustered Electrode: Comparison with Consecutive and Switching Monopolar Modes in Ex Vivo Bovine Livers
title_full_unstemmed Dual Switching Monopolar Radiofrequency Ablation Using a Separable Clustered Electrode: Comparison with Consecutive and Switching Monopolar Modes in Ex Vivo Bovine Livers
title_short Dual Switching Monopolar Radiofrequency Ablation Using a Separable Clustered Electrode: Comparison with Consecutive and Switching Monopolar Modes in Ex Vivo Bovine Livers
title_sort dual switching monopolar radiofrequency ablation using a separable clustered electrode: comparison with consecutive and switching monopolar modes in ex vivo bovine livers
topic Gastrointestinal Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3655292/
https://www.ncbi.nlm.nih.gov/pubmed/23690705
http://dx.doi.org/10.3348/kjr.2013.14.3.403
work_keys_str_mv AT yoonjeonghee dualswitchingmonopolarradiofrequencyablationusingaseparableclusteredelectrodecomparisonwithconsecutiveandswitchingmonopolarmodesinexvivobovinelivers
AT leejeongmin dualswitchingmonopolarradiofrequencyablationusingaseparableclusteredelectrodecomparisonwithconsecutiveandswitchingmonopolarmodesinexvivobovinelivers
AT hanjoonkoo dualswitchingmonopolarradiofrequencyablationusingaseparableclusteredelectrodecomparisonwithconsecutiveandswitchingmonopolarmodesinexvivobovinelivers
AT choibyungihn dualswitchingmonopolarradiofrequencyablationusingaseparableclusteredelectrodecomparisonwithconsecutiveandswitchingmonopolarmodesinexvivobovinelivers