Cargando…
A composite score combining procalcitonin, C-reactive protein and temperature has a high positive predictive value for the diagnosis of intensive care-acquired infections
BACKGROUND: Nosocomial infection diagnosis in the intensive care unit (ICU) remains a challenge. We compared routine measurements of procalcitonin (PCT), C-reactive protein (CRP), white blood cell count (WBC) and temperature in the detection of ICU-acquired infections. METHOD: Prospective observatio...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3655912/ https://www.ncbi.nlm.nih.gov/pubmed/23547830 http://dx.doi.org/10.1186/1471-2334-13-159 |
_version_ | 1782269946401652736 |
---|---|
author | Robriquet, Laurent Séjourné, Caroline Kipnis, Eric D’herbomez, Michele Fourrier, François |
author_facet | Robriquet, Laurent Séjourné, Caroline Kipnis, Eric D’herbomez, Michele Fourrier, François |
author_sort | Robriquet, Laurent |
collection | PubMed |
description | BACKGROUND: Nosocomial infection diagnosis in the intensive care unit (ICU) remains a challenge. We compared routine measurements of procalcitonin (PCT), C-reactive protein (CRP), white blood cell count (WBC) and temperature in the detection of ICU-acquired infections. METHOD: Prospective observational cohort study in a University hospital Medicosurgical ICU. All patients admitted to the ICU ≥ 5 days (n = 141) were included into two groups, either infected (documented infection, n = 25) or non-infected (discharged from the ICU without diagnosis of infection, n = 88). RESULTS: PCT, CRP, WBC and temperature progression from day −4 (D-4) to day 0 (D0) (day of infection diagnosis or ICU discharge) was analysed. Differences (Δ) were calculated as D0 levels minus the lowest preceding value. D0 PCT and CRP were significantly increased in infected compared to non-infected patients (median, 1(st) and 3(rd) quartiles): 3.6 ng/mL (0.92-25) for PCT, 173 mg/L (126–188) for CRP versus 0.02 ng/mL (0.1-0.9) and 57 mg/mL (31–105) respectively (p < 0.0001). In multivariate analysis, D0 temperature > 38.6°C, PCT > 1.86 ng/mL, and CRP > 88 mg/L, performed well (AUCs of 0.88, 0.84, and 0.88 respectively). The sensitivity/specificity profiles of each marker (76%/94% for temperature, 68%/91% for PCT, and 92%/70% for CRP) led to a composite score (0.068 × D0 PCT + 0.005 × D0 CRP + 0.7 × temperature) more highly specific than each component (AUC of 0.90 and sensitivity/specificity of 80%/97%). CONCLUSION: Combining CRP, PCT and temperature is an approach which may increase of nosocomial infection detection in the ICU. |
format | Online Article Text |
id | pubmed-3655912 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-36559122013-05-17 A composite score combining procalcitonin, C-reactive protein and temperature has a high positive predictive value for the diagnosis of intensive care-acquired infections Robriquet, Laurent Séjourné, Caroline Kipnis, Eric D’herbomez, Michele Fourrier, François BMC Infect Dis Research Article BACKGROUND: Nosocomial infection diagnosis in the intensive care unit (ICU) remains a challenge. We compared routine measurements of procalcitonin (PCT), C-reactive protein (CRP), white blood cell count (WBC) and temperature in the detection of ICU-acquired infections. METHOD: Prospective observational cohort study in a University hospital Medicosurgical ICU. All patients admitted to the ICU ≥ 5 days (n = 141) were included into two groups, either infected (documented infection, n = 25) or non-infected (discharged from the ICU without diagnosis of infection, n = 88). RESULTS: PCT, CRP, WBC and temperature progression from day −4 (D-4) to day 0 (D0) (day of infection diagnosis or ICU discharge) was analysed. Differences (Δ) were calculated as D0 levels minus the lowest preceding value. D0 PCT and CRP were significantly increased in infected compared to non-infected patients (median, 1(st) and 3(rd) quartiles): 3.6 ng/mL (0.92-25) for PCT, 173 mg/L (126–188) for CRP versus 0.02 ng/mL (0.1-0.9) and 57 mg/mL (31–105) respectively (p < 0.0001). In multivariate analysis, D0 temperature > 38.6°C, PCT > 1.86 ng/mL, and CRP > 88 mg/L, performed well (AUCs of 0.88, 0.84, and 0.88 respectively). The sensitivity/specificity profiles of each marker (76%/94% for temperature, 68%/91% for PCT, and 92%/70% for CRP) led to a composite score (0.068 × D0 PCT + 0.005 × D0 CRP + 0.7 × temperature) more highly specific than each component (AUC of 0.90 and sensitivity/specificity of 80%/97%). CONCLUSION: Combining CRP, PCT and temperature is an approach which may increase of nosocomial infection detection in the ICU. BioMed Central 2013-04-02 /pmc/articles/PMC3655912/ /pubmed/23547830 http://dx.doi.org/10.1186/1471-2334-13-159 Text en Copyright © 2013 Robriquet et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Robriquet, Laurent Séjourné, Caroline Kipnis, Eric D’herbomez, Michele Fourrier, François A composite score combining procalcitonin, C-reactive protein and temperature has a high positive predictive value for the diagnosis of intensive care-acquired infections |
title | A composite score combining procalcitonin, C-reactive protein and temperature has a high positive predictive value for the diagnosis of intensive care-acquired infections |
title_full | A composite score combining procalcitonin, C-reactive protein and temperature has a high positive predictive value for the diagnosis of intensive care-acquired infections |
title_fullStr | A composite score combining procalcitonin, C-reactive protein and temperature has a high positive predictive value for the diagnosis of intensive care-acquired infections |
title_full_unstemmed | A composite score combining procalcitonin, C-reactive protein and temperature has a high positive predictive value for the diagnosis of intensive care-acquired infections |
title_short | A composite score combining procalcitonin, C-reactive protein and temperature has a high positive predictive value for the diagnosis of intensive care-acquired infections |
title_sort | composite score combining procalcitonin, c-reactive protein and temperature has a high positive predictive value for the diagnosis of intensive care-acquired infections |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3655912/ https://www.ncbi.nlm.nih.gov/pubmed/23547830 http://dx.doi.org/10.1186/1471-2334-13-159 |
work_keys_str_mv | AT robriquetlaurent acompositescorecombiningprocalcitonincreactiveproteinandtemperaturehasahighpositivepredictivevalueforthediagnosisofintensivecareacquiredinfections AT sejournecaroline acompositescorecombiningprocalcitonincreactiveproteinandtemperaturehasahighpositivepredictivevalueforthediagnosisofintensivecareacquiredinfections AT kipniseric acompositescorecombiningprocalcitonincreactiveproteinandtemperaturehasahighpositivepredictivevalueforthediagnosisofintensivecareacquiredinfections AT dherbomezmichele acompositescorecombiningprocalcitonincreactiveproteinandtemperaturehasahighpositivepredictivevalueforthediagnosisofintensivecareacquiredinfections AT fourrierfrancois acompositescorecombiningprocalcitonincreactiveproteinandtemperaturehasahighpositivepredictivevalueforthediagnosisofintensivecareacquiredinfections AT robriquetlaurent compositescorecombiningprocalcitonincreactiveproteinandtemperaturehasahighpositivepredictivevalueforthediagnosisofintensivecareacquiredinfections AT sejournecaroline compositescorecombiningprocalcitonincreactiveproteinandtemperaturehasahighpositivepredictivevalueforthediagnosisofintensivecareacquiredinfections AT kipniseric compositescorecombiningprocalcitonincreactiveproteinandtemperaturehasahighpositivepredictivevalueforthediagnosisofintensivecareacquiredinfections AT dherbomezmichele compositescorecombiningprocalcitonincreactiveproteinandtemperaturehasahighpositivepredictivevalueforthediagnosisofintensivecareacquiredinfections AT fourrierfrancois compositescorecombiningprocalcitonincreactiveproteinandtemperaturehasahighpositivepredictivevalueforthediagnosisofintensivecareacquiredinfections |