Cargando…
A Universal Pedicle Screw and V-Rod System for Lumbar Isthmic Spondylolysis: A Retrospective Analysis of 21 Cases
OBJECTIVE: To investigate the surgical outcome of a universal pedicle screw-V rod system and isthmic bone grafting for isthmic spondylolysis. METHODS: Twenty-four patients with isthmic spondylolysis at L5 and grade 0–I spondylolisthesis (Meyerding classification) received isthmic bone graft and stab...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3656937/ https://www.ncbi.nlm.nih.gov/pubmed/23691090 http://dx.doi.org/10.1371/journal.pone.0063713 |
_version_ | 1782270081924857856 |
---|---|
author | Chen, Xiong-sheng Zhou, Sheng-yuan Jia, Lian-shun Gu, Xiao-min Fang, Lei Zhu, Wei |
author_facet | Chen, Xiong-sheng Zhou, Sheng-yuan Jia, Lian-shun Gu, Xiao-min Fang, Lei Zhu, Wei |
author_sort | Chen, Xiong-sheng |
collection | PubMed |
description | OBJECTIVE: To investigate the surgical outcome of a universal pedicle screw-V rod system and isthmic bone grafting for isthmic spondylolysis. METHODS: Twenty-four patients with isthmic spondylolysis at L5 and grade 0–I spondylolisthesis (Meyerding classification) received isthmic bone graft and stabilization using the universal pedicle screw-V rod system. Back pain was evaluated using the visual analog scale (VAS) and time to bone healing, improvement in spondylolisthesis and intervertebral space height at L5/S1 and L4/L5 were assessed. RESULTS: Twenty-one patients were followed up for 24 months and included in the analysis. Back pain was markedly improved at 3 months postoperatively with a statistical difference in VAS scores compared with preoperative VAS scores (P<0.001). The VAS scores were 0 to 3 at 6 months postoperatively in all patients and no back pain was reported in all patients except 2 patients who complained of back pain after prolonged sitting. X-ray examination showed a bone graft healing time of 3 to 12 months. Grade I spondylolisthesis improved to grade 0 in 4 patients and no noticeable change was observed in the remaining 17 cases. The intervertebral space height at L5/S1 was statistically increased (P<0.05) while no statistically significant change was seen at L4/L5. There was no statistically significant difference in the ROM of the intervertebral disks of L5/S1 and L4/5 before and after surgery. CONCLUSIONS: The universal pedicle screw-V rod system and isthmic bone grafting directly repairs isthmic spondylolysis and reduces back pain, prevents anterior displacement of the diseased segment and maintains intervertebral space height, thus offering a promising alternative to current approaches for isthmic spondylolysis. |
format | Online Article Text |
id | pubmed-3656937 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-36569372013-05-20 A Universal Pedicle Screw and V-Rod System for Lumbar Isthmic Spondylolysis: A Retrospective Analysis of 21 Cases Chen, Xiong-sheng Zhou, Sheng-yuan Jia, Lian-shun Gu, Xiao-min Fang, Lei Zhu, Wei PLoS One Research Article OBJECTIVE: To investigate the surgical outcome of a universal pedicle screw-V rod system and isthmic bone grafting for isthmic spondylolysis. METHODS: Twenty-four patients with isthmic spondylolysis at L5 and grade 0–I spondylolisthesis (Meyerding classification) received isthmic bone graft and stabilization using the universal pedicle screw-V rod system. Back pain was evaluated using the visual analog scale (VAS) and time to bone healing, improvement in spondylolisthesis and intervertebral space height at L5/S1 and L4/L5 were assessed. RESULTS: Twenty-one patients were followed up for 24 months and included in the analysis. Back pain was markedly improved at 3 months postoperatively with a statistical difference in VAS scores compared with preoperative VAS scores (P<0.001). The VAS scores were 0 to 3 at 6 months postoperatively in all patients and no back pain was reported in all patients except 2 patients who complained of back pain after prolonged sitting. X-ray examination showed a bone graft healing time of 3 to 12 months. Grade I spondylolisthesis improved to grade 0 in 4 patients and no noticeable change was observed in the remaining 17 cases. The intervertebral space height at L5/S1 was statistically increased (P<0.05) while no statistically significant change was seen at L4/L5. There was no statistically significant difference in the ROM of the intervertebral disks of L5/S1 and L4/5 before and after surgery. CONCLUSIONS: The universal pedicle screw-V rod system and isthmic bone grafting directly repairs isthmic spondylolysis and reduces back pain, prevents anterior displacement of the diseased segment and maintains intervertebral space height, thus offering a promising alternative to current approaches for isthmic spondylolysis. Public Library of Science 2013-05-17 /pmc/articles/PMC3656937/ /pubmed/23691090 http://dx.doi.org/10.1371/journal.pone.0063713 Text en © 2013 Chen et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Chen, Xiong-sheng Zhou, Sheng-yuan Jia, Lian-shun Gu, Xiao-min Fang, Lei Zhu, Wei A Universal Pedicle Screw and V-Rod System for Lumbar Isthmic Spondylolysis: A Retrospective Analysis of 21 Cases |
title | A Universal Pedicle Screw and V-Rod System for Lumbar Isthmic Spondylolysis: A Retrospective Analysis of 21 Cases |
title_full | A Universal Pedicle Screw and V-Rod System for Lumbar Isthmic Spondylolysis: A Retrospective Analysis of 21 Cases |
title_fullStr | A Universal Pedicle Screw and V-Rod System for Lumbar Isthmic Spondylolysis: A Retrospective Analysis of 21 Cases |
title_full_unstemmed | A Universal Pedicle Screw and V-Rod System for Lumbar Isthmic Spondylolysis: A Retrospective Analysis of 21 Cases |
title_short | A Universal Pedicle Screw and V-Rod System for Lumbar Isthmic Spondylolysis: A Retrospective Analysis of 21 Cases |
title_sort | universal pedicle screw and v-rod system for lumbar isthmic spondylolysis: a retrospective analysis of 21 cases |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3656937/ https://www.ncbi.nlm.nih.gov/pubmed/23691090 http://dx.doi.org/10.1371/journal.pone.0063713 |
work_keys_str_mv | AT chenxiongsheng auniversalpediclescrewandvrodsystemforlumbaristhmicspondylolysisaretrospectiveanalysisof21cases AT zhoushengyuan auniversalpediclescrewandvrodsystemforlumbaristhmicspondylolysisaretrospectiveanalysisof21cases AT jialianshun auniversalpediclescrewandvrodsystemforlumbaristhmicspondylolysisaretrospectiveanalysisof21cases AT guxiaomin auniversalpediclescrewandvrodsystemforlumbaristhmicspondylolysisaretrospectiveanalysisof21cases AT fanglei auniversalpediclescrewandvrodsystemforlumbaristhmicspondylolysisaretrospectiveanalysisof21cases AT zhuwei auniversalpediclescrewandvrodsystemforlumbaristhmicspondylolysisaretrospectiveanalysisof21cases AT chenxiongsheng universalpediclescrewandvrodsystemforlumbaristhmicspondylolysisaretrospectiveanalysisof21cases AT zhoushengyuan universalpediclescrewandvrodsystemforlumbaristhmicspondylolysisaretrospectiveanalysisof21cases AT jialianshun universalpediclescrewandvrodsystemforlumbaristhmicspondylolysisaretrospectiveanalysisof21cases AT guxiaomin universalpediclescrewandvrodsystemforlumbaristhmicspondylolysisaretrospectiveanalysisof21cases AT fanglei universalpediclescrewandvrodsystemforlumbaristhmicspondylolysisaretrospectiveanalysisof21cases AT zhuwei universalpediclescrewandvrodsystemforlumbaristhmicspondylolysisaretrospectiveanalysisof21cases |