Cargando…
Simultaneous determination of paracetamol and lornoxicam by RP-HPLC in bulk and tablet formulation
AIM: The objective of the study was to develop simple RP-HPLC method for the simultaneous determination of paracetamol and lornoxicam without prior separation. MATERIALS AND METHODS: In this method, Kromasil C8 (250 mm, 4.6 mm, 5 μm) column was used. The mobile phase used was methanol:phosphate buff...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658030/ https://www.ncbi.nlm.nih.gov/pubmed/23781432 http://dx.doi.org/10.4103/2229-4708.81084 |
_version_ | 1782270211496345600 |
---|---|
author | Attimarad, Mahesh |
author_facet | Attimarad, Mahesh |
author_sort | Attimarad, Mahesh |
collection | PubMed |
description | AIM: The objective of the study was to develop simple RP-HPLC method for the simultaneous determination of paracetamol and lornoxicam without prior separation. MATERIALS AND METHODS: In this method, Kromasil C8 (250 mm, 4.6 mm, 5 μm) column was used. The mobile phase used was methanol:phosphate buffer (60:40, v/v, pH 6.4), at flow rate of 1 ml min(-1). UV detection was monitored at 302 nm. RESULTS: Calibration graphs were established in the range of 1-150 μg ml(-1) and 0.5-100 μg ml(-1) for paracetamol and lornoxicam, respectively. The average retention time for paracetamol and lornoxicam was found to be 3.15 ± 0.03 min and 5.25 ± 0.06 min, respectively. The detection limit and quantitation limit for paracetamol are 0.19 μg ml(-1) and 0.59 μg ml(-1) and for lornoxicam 0.10 μg ml(-1) and 0.31 μg mL(-1), respectively. The intraday and interday precision expressed as percent relative standard deviation were below 2%. The mean recovery of paracetamol and lornoxicam was found to be in the range of 99.03-101.2%. CONCLUSION: The validated HPLC method was found to be rapid, precise and accurate and can be readily utilized for analysis of paracetamol and lornoxicam in bulk and in pharmaceutical formulations. |
format | Online Article Text |
id | pubmed-3658030 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-36580302013-06-18 Simultaneous determination of paracetamol and lornoxicam by RP-HPLC in bulk and tablet formulation Attimarad, Mahesh Pharm Methods Original Article AIM: The objective of the study was to develop simple RP-HPLC method for the simultaneous determination of paracetamol and lornoxicam without prior separation. MATERIALS AND METHODS: In this method, Kromasil C8 (250 mm, 4.6 mm, 5 μm) column was used. The mobile phase used was methanol:phosphate buffer (60:40, v/v, pH 6.4), at flow rate of 1 ml min(-1). UV detection was monitored at 302 nm. RESULTS: Calibration graphs were established in the range of 1-150 μg ml(-1) and 0.5-100 μg ml(-1) for paracetamol and lornoxicam, respectively. The average retention time for paracetamol and lornoxicam was found to be 3.15 ± 0.03 min and 5.25 ± 0.06 min, respectively. The detection limit and quantitation limit for paracetamol are 0.19 μg ml(-1) and 0.59 μg ml(-1) and for lornoxicam 0.10 μg ml(-1) and 0.31 μg mL(-1), respectively. The intraday and interday precision expressed as percent relative standard deviation were below 2%. The mean recovery of paracetamol and lornoxicam was found to be in the range of 99.03-101.2%. CONCLUSION: The validated HPLC method was found to be rapid, precise and accurate and can be readily utilized for analysis of paracetamol and lornoxicam in bulk and in pharmaceutical formulations. Medknow Publications & Media Pvt Ltd 2011 /pmc/articles/PMC3658030/ /pubmed/23781432 http://dx.doi.org/10.4103/2229-4708.81084 Text en Copyright: © Pharmaceutical Methods http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Attimarad, Mahesh Simultaneous determination of paracetamol and lornoxicam by RP-HPLC in bulk and tablet formulation |
title | Simultaneous determination of paracetamol and lornoxicam by RP-HPLC in bulk and tablet formulation |
title_full | Simultaneous determination of paracetamol and lornoxicam by RP-HPLC in bulk and tablet formulation |
title_fullStr | Simultaneous determination of paracetamol and lornoxicam by RP-HPLC in bulk and tablet formulation |
title_full_unstemmed | Simultaneous determination of paracetamol and lornoxicam by RP-HPLC in bulk and tablet formulation |
title_short | Simultaneous determination of paracetamol and lornoxicam by RP-HPLC in bulk and tablet formulation |
title_sort | simultaneous determination of paracetamol and lornoxicam by rp-hplc in bulk and tablet formulation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658030/ https://www.ncbi.nlm.nih.gov/pubmed/23781432 http://dx.doi.org/10.4103/2229-4708.81084 |
work_keys_str_mv | AT attimaradmahesh simultaneousdeterminationofparacetamolandlornoxicambyrphplcinbulkandtabletformulation |