Simultaneous determination of paracetamol and lornoxicam by RP-HPLC in bulk and tablet formulation

AIM: The objective of the study was to develop simple RP-HPLC method for the simultaneous determination of paracetamol and lornoxicam without prior separation. MATERIALS AND METHODS: In this method, Kromasil C8 (250 mm, 4.6 mm, 5 μm) column was used. The mobile phase used was methanol:phosphate buff...

Descripción completa

Detalles Bibliográficos
Autor principal: Attimarad, Mahesh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658030/
https://www.ncbi.nlm.nih.gov/pubmed/23781432
http://dx.doi.org/10.4103/2229-4708.81084
_version_ 1782270211496345600
author Attimarad, Mahesh
author_facet Attimarad, Mahesh
author_sort Attimarad, Mahesh
collection PubMed
description AIM: The objective of the study was to develop simple RP-HPLC method for the simultaneous determination of paracetamol and lornoxicam without prior separation. MATERIALS AND METHODS: In this method, Kromasil C8 (250 mm, 4.6 mm, 5 μm) column was used. The mobile phase used was methanol:phosphate buffer (60:40, v/v, pH 6.4), at flow rate of 1 ml min(-1). UV detection was monitored at 302 nm. RESULTS: Calibration graphs were established in the range of 1-150 μg ml(-1) and 0.5-100 μg ml(-1) for paracetamol and lornoxicam, respectively. The average retention time for paracetamol and lornoxicam was found to be 3.15 ± 0.03 min and 5.25 ± 0.06 min, respectively. The detection limit and quantitation limit for paracetamol are 0.19 μg ml(-1) and 0.59 μg ml(-1) and for lornoxicam 0.10 μg ml(-1) and 0.31 μg mL(-1), respectively. The intraday and interday precision expressed as percent relative standard deviation were below 2%. The mean recovery of paracetamol and lornoxicam was found to be in the range of 99.03-101.2%. CONCLUSION: The validated HPLC method was found to be rapid, precise and accurate and can be readily utilized for analysis of paracetamol and lornoxicam in bulk and in pharmaceutical formulations.
format Online
Article
Text
id pubmed-3658030
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-36580302013-06-18 Simultaneous determination of paracetamol and lornoxicam by RP-HPLC in bulk and tablet formulation Attimarad, Mahesh Pharm Methods Original Article AIM: The objective of the study was to develop simple RP-HPLC method for the simultaneous determination of paracetamol and lornoxicam without prior separation. MATERIALS AND METHODS: In this method, Kromasil C8 (250 mm, 4.6 mm, 5 μm) column was used. The mobile phase used was methanol:phosphate buffer (60:40, v/v, pH 6.4), at flow rate of 1 ml min(-1). UV detection was monitored at 302 nm. RESULTS: Calibration graphs were established in the range of 1-150 μg ml(-1) and 0.5-100 μg ml(-1) for paracetamol and lornoxicam, respectively. The average retention time for paracetamol and lornoxicam was found to be 3.15 ± 0.03 min and 5.25 ± 0.06 min, respectively. The detection limit and quantitation limit for paracetamol are 0.19 μg ml(-1) and 0.59 μg ml(-1) and for lornoxicam 0.10 μg ml(-1) and 0.31 μg mL(-1), respectively. The intraday and interday precision expressed as percent relative standard deviation were below 2%. The mean recovery of paracetamol and lornoxicam was found to be in the range of 99.03-101.2%. CONCLUSION: The validated HPLC method was found to be rapid, precise and accurate and can be readily utilized for analysis of paracetamol and lornoxicam in bulk and in pharmaceutical formulations. Medknow Publications & Media Pvt Ltd 2011 /pmc/articles/PMC3658030/ /pubmed/23781432 http://dx.doi.org/10.4103/2229-4708.81084 Text en Copyright: © Pharmaceutical Methods http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Attimarad, Mahesh
Simultaneous determination of paracetamol and lornoxicam by RP-HPLC in bulk and tablet formulation
title Simultaneous determination of paracetamol and lornoxicam by RP-HPLC in bulk and tablet formulation
title_full Simultaneous determination of paracetamol and lornoxicam by RP-HPLC in bulk and tablet formulation
title_fullStr Simultaneous determination of paracetamol and lornoxicam by RP-HPLC in bulk and tablet formulation
title_full_unstemmed Simultaneous determination of paracetamol and lornoxicam by RP-HPLC in bulk and tablet formulation
title_short Simultaneous determination of paracetamol and lornoxicam by RP-HPLC in bulk and tablet formulation
title_sort simultaneous determination of paracetamol and lornoxicam by rp-hplc in bulk and tablet formulation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658030/
https://www.ncbi.nlm.nih.gov/pubmed/23781432
http://dx.doi.org/10.4103/2229-4708.81084
work_keys_str_mv AT attimaradmahesh simultaneousdeterminationofparacetamolandlornoxicambyrphplcinbulkandtabletformulation