Development and validation of reversed phase–high-performance liquid chromatography method for determination of paracetamol and lornoxicam in tablet dosage form
A simple, precise, reliable, rapid and reproducible reversed phase–high-performance liquid chromatography method was developed and validated for the simultaneous estimation of Paracetamol (PCM) and Lornoxicam (LOX) present in tablet dosage forms. Chromatographic separation achieved isocratically on...