Cargando…

A validated high-performance thin layer chromatography method for estimation of lornoxicam and paracetamol in their combined tablet dosage form

INTRODUCTION: Lornoxicam (LORN) a nonsteroidal antiinflammatory drug of oxicam class is marketed in combination with Paracetamol, a common analgesic for acute inflammatory disease of joints. MATERIALS AND METHODS: LORN and Paracetamol (PCM) were estimated at 280 nm by densitometry using silica gel 6...

Descripción completa

Detalles Bibliográficos
Autores principales: Borisagar, Sanjay L., Patel, H. U., Patel, C. N., Jayswal, Ujjawal P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658044/
https://www.ncbi.nlm.nih.gov/pubmed/23781435
http://dx.doi.org/10.4103/2229-4708.84440
_version_ 1782270214673530880
author Borisagar, Sanjay L.
Patel, H. U.
Patel, C. N.
Jayswal, Ujjawal P.
author_facet Borisagar, Sanjay L.
Patel, H. U.
Patel, C. N.
Jayswal, Ujjawal P.
author_sort Borisagar, Sanjay L.
collection PubMed
description INTRODUCTION: Lornoxicam (LORN) a nonsteroidal antiinflammatory drug of oxicam class is marketed in combination with Paracetamol, a common analgesic for acute inflammatory disease of joints. MATERIALS AND METHODS: LORN and Paracetamol (PCM) were estimated at 280 nm by densitometry using silica gel 60 F(254) as stationary phase and a premix of toluene: chloroform: methanol: formic acid (3:5:1.5:0.2 v/v/v/v) as mobile phase. The method was found linear in a range of 160–560 nanograms/spot for LORN and 10 000–35 000 nanograms/spot for PCM with a correlation coefficient >0.99 for both. RESULT: PCM and LORN were well resolved with Rf 0.57 ± 0.02 and 0.75 ± 0.02, respectively. CONCLUSIONS: The developed high-performance thin layer chromatography method was found to be simple, specific, precise, and reproducible and can be used for the routine estimation of LORN and PCM in the combined tablet dosage form, available in market.
format Online
Article
Text
id pubmed-3658044
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-36580442013-06-18 A validated high-performance thin layer chromatography method for estimation of lornoxicam and paracetamol in their combined tablet dosage form Borisagar, Sanjay L. Patel, H. U. Patel, C. N. Jayswal, Ujjawal P. Pharm Methods Original Article INTRODUCTION: Lornoxicam (LORN) a nonsteroidal antiinflammatory drug of oxicam class is marketed in combination with Paracetamol, a common analgesic for acute inflammatory disease of joints. MATERIALS AND METHODS: LORN and Paracetamol (PCM) were estimated at 280 nm by densitometry using silica gel 60 F(254) as stationary phase and a premix of toluene: chloroform: methanol: formic acid (3:5:1.5:0.2 v/v/v/v) as mobile phase. The method was found linear in a range of 160–560 nanograms/spot for LORN and 10 000–35 000 nanograms/spot for PCM with a correlation coefficient >0.99 for both. RESULT: PCM and LORN were well resolved with Rf 0.57 ± 0.02 and 0.75 ± 0.02, respectively. CONCLUSIONS: The developed high-performance thin layer chromatography method was found to be simple, specific, precise, and reproducible and can be used for the routine estimation of LORN and PCM in the combined tablet dosage form, available in market. Medknow Publications & Media Pvt Ltd 2011 /pmc/articles/PMC3658044/ /pubmed/23781435 http://dx.doi.org/10.4103/2229-4708.84440 Text en Copyright: © Pharmaceutical Methods http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Borisagar, Sanjay L.
Patel, H. U.
Patel, C. N.
Jayswal, Ujjawal P.
A validated high-performance thin layer chromatography method for estimation of lornoxicam and paracetamol in their combined tablet dosage form
title A validated high-performance thin layer chromatography method for estimation of lornoxicam and paracetamol in their combined tablet dosage form
title_full A validated high-performance thin layer chromatography method for estimation of lornoxicam and paracetamol in their combined tablet dosage form
title_fullStr A validated high-performance thin layer chromatography method for estimation of lornoxicam and paracetamol in their combined tablet dosage form
title_full_unstemmed A validated high-performance thin layer chromatography method for estimation of lornoxicam and paracetamol in their combined tablet dosage form
title_short A validated high-performance thin layer chromatography method for estimation of lornoxicam and paracetamol in their combined tablet dosage form
title_sort validated high-performance thin layer chromatography method for estimation of lornoxicam and paracetamol in their combined tablet dosage form
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658044/
https://www.ncbi.nlm.nih.gov/pubmed/23781435
http://dx.doi.org/10.4103/2229-4708.84440
work_keys_str_mv AT borisagarsanjayl avalidatedhighperformancethinlayerchromatographymethodforestimationoflornoxicamandparacetamolintheircombinedtabletdosageform
AT patelhu avalidatedhighperformancethinlayerchromatographymethodforestimationoflornoxicamandparacetamolintheircombinedtabletdosageform
AT patelcn avalidatedhighperformancethinlayerchromatographymethodforestimationoflornoxicamandparacetamolintheircombinedtabletdosageform
AT jayswalujjawalp avalidatedhighperformancethinlayerchromatographymethodforestimationoflornoxicamandparacetamolintheircombinedtabletdosageform
AT borisagarsanjayl validatedhighperformancethinlayerchromatographymethodforestimationoflornoxicamandparacetamolintheircombinedtabletdosageform
AT patelhu validatedhighperformancethinlayerchromatographymethodforestimationoflornoxicamandparacetamolintheircombinedtabletdosageform
AT patelcn validatedhighperformancethinlayerchromatographymethodforestimationoflornoxicamandparacetamolintheircombinedtabletdosageform
AT jayswalujjawalp validatedhighperformancethinlayerchromatographymethodforestimationoflornoxicamandparacetamolintheircombinedtabletdosageform