Cargando…

Simultaneous analysis of eprosartan and hydrochlorothiazide in tablets by high-performance liquid chromatography

OBJECTIVE: A simple, precise and accurate isocratic reversed phase (RP) column high-performance liquid chromatographic (HPLC) method has been developed for simultaneous analysis of eprosartan (EPR) and hydrochlorothiazide (HCT) in tablet formulations. MATERIALS AND METHODS: Isocratic RP-HPLC separat...

Descripción completa

Detalles Bibliográficos
Autores principales: Patel, Harsha U., Suhagia, Bhanubhai N., Patel, Chhaganbhai N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658045/
https://www.ncbi.nlm.nih.gov/pubmed/23781445
http://dx.doi.org/10.4103/2229-4708.84456
_version_ 1782270214904217600
author Patel, Harsha U.
Suhagia, Bhanubhai N.
Patel, Chhaganbhai N.
author_facet Patel, Harsha U.
Suhagia, Bhanubhai N.
Patel, Chhaganbhai N.
author_sort Patel, Harsha U.
collection PubMed
description OBJECTIVE: A simple, precise and accurate isocratic reversed phase (RP) column high-performance liquid chromatographic (HPLC) method has been developed for simultaneous analysis of eprosartan (EPR) and hydrochlorothiazide (HCT) in tablet formulations. MATERIALS AND METHODS: Isocratic RP-HPLC separation was achieved on phenomenex C18 column (250 × 4.6 mm i.d., 5 μm particle size) using mobile phase composed of 0.5% formic acid-methanol-acetonitrile [(80 : 25 : 20 v/v/v) pH, 2.80 ± 0.04] at a flow rate of 1.0 ml/min. The retention time for EPR and HCT was 7.69 ± 0.10 and 4.24 ± 0.09 minutes, respectively. The detection was performed at 272 nm. RESULTS: The method was linear in the concentration range of 60-600 μg/ml for EPR and 2.5-25 μg/ml for HCT with a correlation coefficient of 0.9992 and 0.9997, respectively. The repeatability for six samples was 0.53 and 0.61 % RSD for EPR and HCT, respectively. The accuracy (recovery) was found to be in the range of 99.46 to 100.61% for EPR and 99.06 to 100.93% for HCT, respectively. CONCLUSIONS: The method was validated and successfully used for determination of the drugs in tablets.
format Online
Article
Text
id pubmed-3658045
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-36580452013-06-18 Simultaneous analysis of eprosartan and hydrochlorothiazide in tablets by high-performance liquid chromatography Patel, Harsha U. Suhagia, Bhanubhai N. Patel, Chhaganbhai N. Pharm Methods Original Article OBJECTIVE: A simple, precise and accurate isocratic reversed phase (RP) column high-performance liquid chromatographic (HPLC) method has been developed for simultaneous analysis of eprosartan (EPR) and hydrochlorothiazide (HCT) in tablet formulations. MATERIALS AND METHODS: Isocratic RP-HPLC separation was achieved on phenomenex C18 column (250 × 4.6 mm i.d., 5 μm particle size) using mobile phase composed of 0.5% formic acid-methanol-acetonitrile [(80 : 25 : 20 v/v/v) pH, 2.80 ± 0.04] at a flow rate of 1.0 ml/min. The retention time for EPR and HCT was 7.69 ± 0.10 and 4.24 ± 0.09 minutes, respectively. The detection was performed at 272 nm. RESULTS: The method was linear in the concentration range of 60-600 μg/ml for EPR and 2.5-25 μg/ml for HCT with a correlation coefficient of 0.9992 and 0.9997, respectively. The repeatability for six samples was 0.53 and 0.61 % RSD for EPR and HCT, respectively. The accuracy (recovery) was found to be in the range of 99.46 to 100.61% for EPR and 99.06 to 100.93% for HCT, respectively. CONCLUSIONS: The method was validated and successfully used for determination of the drugs in tablets. Medknow Publications & Media Pvt Ltd 2011 /pmc/articles/PMC3658045/ /pubmed/23781445 http://dx.doi.org/10.4103/2229-4708.84456 Text en Copyright: © Pharmaceutical Methods http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Patel, Harsha U.
Suhagia, Bhanubhai N.
Patel, Chhaganbhai N.
Simultaneous analysis of eprosartan and hydrochlorothiazide in tablets by high-performance liquid chromatography
title Simultaneous analysis of eprosartan and hydrochlorothiazide in tablets by high-performance liquid chromatography
title_full Simultaneous analysis of eprosartan and hydrochlorothiazide in tablets by high-performance liquid chromatography
title_fullStr Simultaneous analysis of eprosartan and hydrochlorothiazide in tablets by high-performance liquid chromatography
title_full_unstemmed Simultaneous analysis of eprosartan and hydrochlorothiazide in tablets by high-performance liquid chromatography
title_short Simultaneous analysis of eprosartan and hydrochlorothiazide in tablets by high-performance liquid chromatography
title_sort simultaneous analysis of eprosartan and hydrochlorothiazide in tablets by high-performance liquid chromatography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658045/
https://www.ncbi.nlm.nih.gov/pubmed/23781445
http://dx.doi.org/10.4103/2229-4708.84456
work_keys_str_mv AT patelharshau simultaneousanalysisofeprosartanandhydrochlorothiazideintabletsbyhighperformanceliquidchromatography
AT suhagiabhanubhain simultaneousanalysisofeprosartanandhydrochlorothiazideintabletsbyhighperformanceliquidchromatography
AT patelchhaganbhain simultaneousanalysisofeprosartanandhydrochlorothiazideintabletsbyhighperformanceliquidchromatography