Cargando…

Simultaneous analysis of eprosartan and hydrochlorothiazide in tablets by high-performance liquid chromatography

OBJECTIVE: A simple, precise and accurate isocratic reversed phase (RP) column high-performance liquid chromatographic (HPLC) method has been developed for simultaneous analysis of eprosartan (EPR) and hydrochlorothiazide (HCT) in tablet formulations. MATERIALS AND METHODS: Isocratic RP-HPLC separat...

Descripción completa

Detalles Bibliográficos
Autores principales: Patel, Harsha U., Suhagia, Bhanubhai N., Patel, Chhaganbhai N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658045/
https://www.ncbi.nlm.nih.gov/pubmed/23781445
http://dx.doi.org/10.4103/2229-4708.84456