Simultaneous analysis of eprosartan and hydrochlorothiazide in tablets by high-performance liquid chromatography

OBJECTIVE: A simple, precise and accurate isocratic reversed phase (RP) column high-performance liquid chromatographic (HPLC) method has been developed for simultaneous analysis of eprosartan (EPR) and hydrochlorothiazide (HCT) in tablet formulations. MATERIALS AND METHODS: Isocratic RP-HPLC separat...