Cargando…
Validation of a simple RP-HPLC method developed for the quantification of meta-cresol in parathyroid hormones formulation
AIM: To develop and validate a rapid and sensitive reverse phase high performance liquid chromatography (RP-HPLC) method with UV detection for quantification of meta-cresol (m-cresol) in pharmaceutical preparation of parathyroid hormone (1–34) (PTH). MATERIALS AND METHODS: Chromatography was perform...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658057/ https://www.ncbi.nlm.nih.gov/pubmed/23781457 http://dx.doi.org/10.4103/2229-4708.90366 |
_version_ | 1782270217671409664 |
---|---|
author | Rane, Shaligram S. Ajameri, Alkesh Mody, Rustom Padmaja, P. |
author_facet | Rane, Shaligram S. Ajameri, Alkesh Mody, Rustom Padmaja, P. |
author_sort | Rane, Shaligram S. |
collection | PubMed |
description | AIM: To develop and validate a rapid and sensitive reverse phase high performance liquid chromatography (RP-HPLC) method with UV detection for quantification of meta-cresol (m-cresol) in pharmaceutical preparation of parathyroid hormone (1–34) (PTH). MATERIALS AND METHODS: Chromatography was performed on a Jupiter RP C-18 (4.6 mm ID × 250 mm L, porosity 300 Å, particle size 5 μm) with a guard column (reversed-phase C(18) column of 4.6 mm ID × 12.5 mm L, porosity 300 Å, particle size 5 μm) using a mobile phase containing 0.1% TFA in 60% methanol with isocratic program at 1.0 mL/min flow rate. Detection was carried out at 217 nm. The method was validated as per ICH guidelines for linearity (correlation coefficient = 0.99), range, accuracy, precision, and robustness (n = 9 during accuracy parameter whereas n =15 during linearity and range parameter and n = 6 during repeatability). Robustness was confirmed by considering two factors; age effect of the mobile phase and test sample and with different columns during method development. RESULTS: The method was linear over the concentration range of 75–120 μg/mL. The precision of the method in terms of relative standard deviation was evaluated from intra- and inter-day replicate injections of system suitability standards of m-cresol using different equipment and different columns. Components of within- and between-batch variances were found to be below 2% (n = 30) and 3%, respectively, which constituted an acceptable level of variation. Retention time was found to be about 5.2 min and 10.9 min for m-cresol and PTH, respectively. CONCLUSION: The developed method thus has the potential of being useful for routine quality control of m-cresol. |
format | Online Article Text |
id | pubmed-3658057 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-36580572013-06-18 Validation of a simple RP-HPLC method developed for the quantification of meta-cresol in parathyroid hormones formulation Rane, Shaligram S. Ajameri, Alkesh Mody, Rustom Padmaja, P. Pharm Methods Original Article AIM: To develop and validate a rapid and sensitive reverse phase high performance liquid chromatography (RP-HPLC) method with UV detection for quantification of meta-cresol (m-cresol) in pharmaceutical preparation of parathyroid hormone (1–34) (PTH). MATERIALS AND METHODS: Chromatography was performed on a Jupiter RP C-18 (4.6 mm ID × 250 mm L, porosity 300 Å, particle size 5 μm) with a guard column (reversed-phase C(18) column of 4.6 mm ID × 12.5 mm L, porosity 300 Å, particle size 5 μm) using a mobile phase containing 0.1% TFA in 60% methanol with isocratic program at 1.0 mL/min flow rate. Detection was carried out at 217 nm. The method was validated as per ICH guidelines for linearity (correlation coefficient = 0.99), range, accuracy, precision, and robustness (n = 9 during accuracy parameter whereas n =15 during linearity and range parameter and n = 6 during repeatability). Robustness was confirmed by considering two factors; age effect of the mobile phase and test sample and with different columns during method development. RESULTS: The method was linear over the concentration range of 75–120 μg/mL. The precision of the method in terms of relative standard deviation was evaluated from intra- and inter-day replicate injections of system suitability standards of m-cresol using different equipment and different columns. Components of within- and between-batch variances were found to be below 2% (n = 30) and 3%, respectively, which constituted an acceptable level of variation. Retention time was found to be about 5.2 min and 10.9 min for m-cresol and PTH, respectively. CONCLUSION: The developed method thus has the potential of being useful for routine quality control of m-cresol. Medknow Publications & Media Pvt Ltd 2011 /pmc/articles/PMC3658057/ /pubmed/23781457 http://dx.doi.org/10.4103/2229-4708.90366 Text en Copyright: © Pharmaceutical Methods http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Rane, Shaligram S. Ajameri, Alkesh Mody, Rustom Padmaja, P. Validation of a simple RP-HPLC method developed for the quantification of meta-cresol in parathyroid hormones formulation |
title | Validation of a simple RP-HPLC method developed for the quantification of meta-cresol in parathyroid hormones formulation |
title_full | Validation of a simple RP-HPLC method developed for the quantification of meta-cresol in parathyroid hormones formulation |
title_fullStr | Validation of a simple RP-HPLC method developed for the quantification of meta-cresol in parathyroid hormones formulation |
title_full_unstemmed | Validation of a simple RP-HPLC method developed for the quantification of meta-cresol in parathyroid hormones formulation |
title_short | Validation of a simple RP-HPLC method developed for the quantification of meta-cresol in parathyroid hormones formulation |
title_sort | validation of a simple rp-hplc method developed for the quantification of meta-cresol in parathyroid hormones formulation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658057/ https://www.ncbi.nlm.nih.gov/pubmed/23781457 http://dx.doi.org/10.4103/2229-4708.90366 |
work_keys_str_mv | AT raneshaligrams validationofasimplerphplcmethoddevelopedforthequantificationofmetacresolinparathyroidhormonesformulation AT ajamerialkesh validationofasimplerphplcmethoddevelopedforthequantificationofmetacresolinparathyroidhormonesformulation AT modyrustom validationofasimplerphplcmethoddevelopedforthequantificationofmetacresolinparathyroidhormonesformulation AT padmajap validationofasimplerphplcmethoddevelopedforthequantificationofmetacresolinparathyroidhormonesformulation |