Reliability of a New Stabilized Dynamometer System for the Evaluation of Hip Strength

BACKGROUND: Hip strength is associated with numerous orthopaedic and neuromuscular injuries and/or pathologies and may be assessed with a variety of anatomic testing positions and techniques. Isokinetic dynamometers are generally too cumbersome and intricate for efficient use in mass screenings (for...

Descripción completa

Detalles Bibliográficos
Autores principales: Tourville, Timothy W., Smith, Helen C., Shultz, Sandra J., Vacek, Pamela M., Slauterbeck, James R., Johnson, Robert J., Beynnon, Bruce D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658376/
https://www.ncbi.nlm.nih.gov/pubmed/24427380
http://dx.doi.org/10.1177/1941738112459486
_version_ 1782270261147467776
author Tourville, Timothy W.
Smith, Helen C.
Shultz, Sandra J.
Vacek, Pamela M.
Slauterbeck, James R.
Johnson, Robert J.
Beynnon, Bruce D.
author_facet Tourville, Timothy W.
Smith, Helen C.
Shultz, Sandra J.
Vacek, Pamela M.
Slauterbeck, James R.
Johnson, Robert J.
Beynnon, Bruce D.
author_sort Tourville, Timothy W.
collection PubMed
description BACKGROUND: Hip strength is associated with numerous orthopaedic and neuromuscular injuries and/or pathologies and may be assessed with a variety of anatomic testing positions and techniques. Isokinetic dynamometers are generally too cumbersome and intricate for efficient use in mass screenings (for prognostic studies of risk for injury) as well as with special populations. The reliability of isometric testing devices has demonstrated varied reliability, generally examining only 1 or 2 motions of the hip and reporting values of force, not torque. Consequently, there is a need for an efficient hip strength-testing device to quantify torque that tests subjects in 1 anatomic position, while evaluating multiple hip motions. HYPOTHESIS: Evaluation of supine hip abduction, adduction, flexion, and extension torque using a new stabilized dynamometer system will produce good to excellent intra- and interexaminer reliability results. STUDY DESIGN: A blinded, randomized, repeated-measures study design was used in this descriptive laboratory investigation. METHODS: Supine isometric hip flexion, extension, abduction, and adduction torques were evaluated with a cage-stabilized dynamometer in 19 collegiate and professional-level ice hockey athletes by 2 investigators at 3 time intervals. Inter- and intrarater reliability was assessed. RESULTS: Supine hip flexion, extension, abduction, and adduction torque was performed with good to excellent inter- and intrarater reliability (intraclass correlation coefficients ranging from 0.74 to 0.92 and 0.78 to 0.92, respectively) for all motions tested. CONCLUSIONS: We have developed an isometric hip strength-testing device that can be assembled around an examination table to efficiently and reliably evaluate torque developed for multiple motions of the hip. CLINICAL RELEVANCE: This device and testing protocol may be used to efficiently evaluate hip strength in numerous settings; it allows decreased subject burden and increased comfort (which may be important following an injury in case-control investigations); and it may be well tolerated when testing athletes as well as special populations in the clinical setting.
format Online
Article
Text
id pubmed-3658376
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-36583762014-03-01 Reliability of a New Stabilized Dynamometer System for the Evaluation of Hip Strength Tourville, Timothy W. Smith, Helen C. Shultz, Sandra J. Vacek, Pamela M. Slauterbeck, James R. Johnson, Robert J. Beynnon, Bruce D. Sports Health Sports Physical Therapy BACKGROUND: Hip strength is associated with numerous orthopaedic and neuromuscular injuries and/or pathologies and may be assessed with a variety of anatomic testing positions and techniques. Isokinetic dynamometers are generally too cumbersome and intricate for efficient use in mass screenings (for prognostic studies of risk for injury) as well as with special populations. The reliability of isometric testing devices has demonstrated varied reliability, generally examining only 1 or 2 motions of the hip and reporting values of force, not torque. Consequently, there is a need for an efficient hip strength-testing device to quantify torque that tests subjects in 1 anatomic position, while evaluating multiple hip motions. HYPOTHESIS: Evaluation of supine hip abduction, adduction, flexion, and extension torque using a new stabilized dynamometer system will produce good to excellent intra- and interexaminer reliability results. STUDY DESIGN: A blinded, randomized, repeated-measures study design was used in this descriptive laboratory investigation. METHODS: Supine isometric hip flexion, extension, abduction, and adduction torques were evaluated with a cage-stabilized dynamometer in 19 collegiate and professional-level ice hockey athletes by 2 investigators at 3 time intervals. Inter- and intrarater reliability was assessed. RESULTS: Supine hip flexion, extension, abduction, and adduction torque was performed with good to excellent inter- and intrarater reliability (intraclass correlation coefficients ranging from 0.74 to 0.92 and 0.78 to 0.92, respectively) for all motions tested. CONCLUSIONS: We have developed an isometric hip strength-testing device that can be assembled around an examination table to efficiently and reliably evaluate torque developed for multiple motions of the hip. CLINICAL RELEVANCE: This device and testing protocol may be used to efficiently evaluate hip strength in numerous settings; it allows decreased subject burden and increased comfort (which may be important following an injury in case-control investigations); and it may be well tolerated when testing athletes as well as special populations in the clinical setting. SAGE Publications 2013-03 /pmc/articles/PMC3658376/ /pubmed/24427380 http://dx.doi.org/10.1177/1941738112459486 Text en © 2012 The Author(s)
spellingShingle Sports Physical Therapy
Tourville, Timothy W.
Smith, Helen C.
Shultz, Sandra J.
Vacek, Pamela M.
Slauterbeck, James R.
Johnson, Robert J.
Beynnon, Bruce D.
Reliability of a New Stabilized Dynamometer System for the Evaluation of Hip Strength
title Reliability of a New Stabilized Dynamometer System for the Evaluation of Hip Strength
title_full Reliability of a New Stabilized Dynamometer System for the Evaluation of Hip Strength
title_fullStr Reliability of a New Stabilized Dynamometer System for the Evaluation of Hip Strength
title_full_unstemmed Reliability of a New Stabilized Dynamometer System for the Evaluation of Hip Strength
title_short Reliability of a New Stabilized Dynamometer System for the Evaluation of Hip Strength
title_sort reliability of a new stabilized dynamometer system for the evaluation of hip strength
topic Sports Physical Therapy
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658376/
https://www.ncbi.nlm.nih.gov/pubmed/24427380
http://dx.doi.org/10.1177/1941738112459486
work_keys_str_mv AT tourvilletimothyw reliabilityofanewstabilizeddynamometersystemfortheevaluationofhipstrength
AT smithhelenc reliabilityofanewstabilizeddynamometersystemfortheevaluationofhipstrength
AT shultzsandraj reliabilityofanewstabilizeddynamometersystemfortheevaluationofhipstrength
AT vacekpamelam reliabilityofanewstabilizeddynamometersystemfortheevaluationofhipstrength
AT slauterbeckjamesr reliabilityofanewstabilizeddynamometersystemfortheevaluationofhipstrength
AT johnsonrobertj reliabilityofanewstabilizeddynamometersystemfortheevaluationofhipstrength
AT beynnonbruced reliabilityofanewstabilizeddynamometersystemfortheevaluationofhipstrength