Cargando…
Eye-Tracker-Guided Non-Mechanical Excimer Laser Assisted Penetrating Keratoplasty
Purpose: The purpose of the study was to implement a new eye tracking mask which could be used to guide the laser beam in automated non-mechanical excimer laser assisted penetrating keratoplasty. Materials and methods: A new trephination mask design with an elevated surface geometry has been propose...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658773/ https://www.ncbi.nlm.nih.gov/pubmed/23507821 http://dx.doi.org/10.3390/s130303753 |
_version_ | 1782270331521597440 |
---|---|
author | Janunts, Edgar Schirra, Frank Szentmáry, Nora Seitz, Berthold Langenbucher, Achim |
author_facet | Janunts, Edgar Schirra, Frank Szentmáry, Nora Seitz, Berthold Langenbucher, Achim |
author_sort | Janunts, Edgar |
collection | PubMed |
description | Purpose: The purpose of the study was to implement a new eye tracking mask which could be used to guide the laser beam in automated non-mechanical excimer laser assisted penetrating keratoplasty. Materials and methods: A new trephination mask design with an elevated surface geometry has been proposed with a step formation between conical and flat interfaces. Two recipient masks of 7.5/8.0 mm have been manufactured and tested. The masks have outer diameter of 12.5 mm, step formation at 10.5 mm, and slope of conical surfaces 15°. Its functionality has been tested in different lateral positions and tilts on a planar surface, and pig eye experiments. After successful validation on porcine eyes, new masks have been produced and tested on two patients. Results: The build-in eye tracking software of the MEL 70 was always able to capture the masks. It has been shown that the unwanted pigmentation/pattern induced by the laser pulses on the mask surface does not influence the eye-tracking efficiency. The masks could be tracked within the 18 × 14 mm lateral displacement and up to 12° tilt. Two patient cases are demonstrated. No complications were observed during the surgery, although it needs some attention for aligning the mask horizontally before trephination. Stability of eye tracking masks is emphasized by inducing on purpose movements of the patient head. Conclusion: Eye-tracking-guided penetrating keratoplasty was successfully applied in clinical practice, which enables robust tracking criteria within an extended range. It facilitates the automated trephination procedure of excimer laser-assisted penetrating keratoplasty. |
format | Online Article Text |
id | pubmed-3658773 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-36587732013-05-30 Eye-Tracker-Guided Non-Mechanical Excimer Laser Assisted Penetrating Keratoplasty Janunts, Edgar Schirra, Frank Szentmáry, Nora Seitz, Berthold Langenbucher, Achim Sensors (Basel) Article Purpose: The purpose of the study was to implement a new eye tracking mask which could be used to guide the laser beam in automated non-mechanical excimer laser assisted penetrating keratoplasty. Materials and methods: A new trephination mask design with an elevated surface geometry has been proposed with a step formation between conical and flat interfaces. Two recipient masks of 7.5/8.0 mm have been manufactured and tested. The masks have outer diameter of 12.5 mm, step formation at 10.5 mm, and slope of conical surfaces 15°. Its functionality has been tested in different lateral positions and tilts on a planar surface, and pig eye experiments. After successful validation on porcine eyes, new masks have been produced and tested on two patients. Results: The build-in eye tracking software of the MEL 70 was always able to capture the masks. It has been shown that the unwanted pigmentation/pattern induced by the laser pulses on the mask surface does not influence the eye-tracking efficiency. The masks could be tracked within the 18 × 14 mm lateral displacement and up to 12° tilt. Two patient cases are demonstrated. No complications were observed during the surgery, although it needs some attention for aligning the mask horizontally before trephination. Stability of eye tracking masks is emphasized by inducing on purpose movements of the patient head. Conclusion: Eye-tracking-guided penetrating keratoplasty was successfully applied in clinical practice, which enables robust tracking criteria within an extended range. It facilitates the automated trephination procedure of excimer laser-assisted penetrating keratoplasty. Molecular Diversity Preservation International (MDPI) 2013-03-18 /pmc/articles/PMC3658773/ /pubmed/23507821 http://dx.doi.org/10.3390/s130303753 Text en © 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Janunts, Edgar Schirra, Frank Szentmáry, Nora Seitz, Berthold Langenbucher, Achim Eye-Tracker-Guided Non-Mechanical Excimer Laser Assisted Penetrating Keratoplasty |
title | Eye-Tracker-Guided Non-Mechanical Excimer Laser Assisted Penetrating Keratoplasty |
title_full | Eye-Tracker-Guided Non-Mechanical Excimer Laser Assisted Penetrating Keratoplasty |
title_fullStr | Eye-Tracker-Guided Non-Mechanical Excimer Laser Assisted Penetrating Keratoplasty |
title_full_unstemmed | Eye-Tracker-Guided Non-Mechanical Excimer Laser Assisted Penetrating Keratoplasty |
title_short | Eye-Tracker-Guided Non-Mechanical Excimer Laser Assisted Penetrating Keratoplasty |
title_sort | eye-tracker-guided non-mechanical excimer laser assisted penetrating keratoplasty |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658773/ https://www.ncbi.nlm.nih.gov/pubmed/23507821 http://dx.doi.org/10.3390/s130303753 |
work_keys_str_mv | AT januntsedgar eyetrackerguidednonmechanicalexcimerlaserassistedpenetratingkeratoplasty AT schirrafrank eyetrackerguidednonmechanicalexcimerlaserassistedpenetratingkeratoplasty AT szentmarynora eyetrackerguidednonmechanicalexcimerlaserassistedpenetratingkeratoplasty AT seitzberthold eyetrackerguidednonmechanicalexcimerlaserassistedpenetratingkeratoplasty AT langenbucherachim eyetrackerguidednonmechanicalexcimerlaserassistedpenetratingkeratoplasty |