Cargando…
Sliding Window-Based Region of Interest Extraction for Finger Vein Images
Region of Interest (ROI) extraction is a crucial step in an automatic finger vein recognition system. The aim of ROI extraction is to decide which part of the image is suitable for finger vein feature extraction. This paper proposes a finger vein ROI extraction method which is robust to finger displ...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658776/ https://www.ncbi.nlm.nih.gov/pubmed/23507824 http://dx.doi.org/10.3390/s130303799 |
_version_ | 1782270332215754752 |
---|---|
author | Yang, Lu Yang, Gongping Yin, Yilong Xiao, Rongyang |
author_facet | Yang, Lu Yang, Gongping Yin, Yilong Xiao, Rongyang |
author_sort | Yang, Lu |
collection | PubMed |
description | Region of Interest (ROI) extraction is a crucial step in an automatic finger vein recognition system. The aim of ROI extraction is to decide which part of the image is suitable for finger vein feature extraction. This paper proposes a finger vein ROI extraction method which is robust to finger displacement and rotation. First, we determine the middle line of the finger, which will be used to correct the image skew. Then, a sliding window is used to detect the phalangeal joints and further to ascertain the height of ROI. Last, for the corrective image with certain height, we will obtain the ROI by using the internal tangents of finger edges as the left and right boundary. The experimental results show that the proposed method can extract ROI more accurately and effectively compared with other methods, and thus improve the performance of finger vein identification system. Besides, to acquire the high quality finger vein image during the capture process, we propose eight criteria for finger vein capture from different aspects and these criteria should be helpful to some extent for finger vein capture. |
format | Online Article Text |
id | pubmed-3658776 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-36587762013-05-30 Sliding Window-Based Region of Interest Extraction for Finger Vein Images Yang, Lu Yang, Gongping Yin, Yilong Xiao, Rongyang Sensors (Basel) Article Region of Interest (ROI) extraction is a crucial step in an automatic finger vein recognition system. The aim of ROI extraction is to decide which part of the image is suitable for finger vein feature extraction. This paper proposes a finger vein ROI extraction method which is robust to finger displacement and rotation. First, we determine the middle line of the finger, which will be used to correct the image skew. Then, a sliding window is used to detect the phalangeal joints and further to ascertain the height of ROI. Last, for the corrective image with certain height, we will obtain the ROI by using the internal tangents of finger edges as the left and right boundary. The experimental results show that the proposed method can extract ROI more accurately and effectively compared with other methods, and thus improve the performance of finger vein identification system. Besides, to acquire the high quality finger vein image during the capture process, we propose eight criteria for finger vein capture from different aspects and these criteria should be helpful to some extent for finger vein capture. Molecular Diversity Preservation International (MDPI) 2013-03-18 /pmc/articles/PMC3658776/ /pubmed/23507824 http://dx.doi.org/10.3390/s130303799 Text en © 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Yang, Lu Yang, Gongping Yin, Yilong Xiao, Rongyang Sliding Window-Based Region of Interest Extraction for Finger Vein Images |
title | Sliding Window-Based Region of Interest Extraction for Finger Vein Images |
title_full | Sliding Window-Based Region of Interest Extraction for Finger Vein Images |
title_fullStr | Sliding Window-Based Region of Interest Extraction for Finger Vein Images |
title_full_unstemmed | Sliding Window-Based Region of Interest Extraction for Finger Vein Images |
title_short | Sliding Window-Based Region of Interest Extraction for Finger Vein Images |
title_sort | sliding window-based region of interest extraction for finger vein images |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658776/ https://www.ncbi.nlm.nih.gov/pubmed/23507824 http://dx.doi.org/10.3390/s130303799 |
work_keys_str_mv | AT yanglu slidingwindowbasedregionofinterestextractionforfingerveinimages AT yanggongping slidingwindowbasedregionofinterestextractionforfingerveinimages AT yinyilong slidingwindowbasedregionofinterestextractionforfingerveinimages AT xiaorongyang slidingwindowbasedregionofinterestextractionforfingerveinimages |