Cargando…

Measurements of Tropospheric NO(2) in Romania Using a Zenith-Sky Mobile DOAS System and Comparisons with Satellite Observations

In this paper we present a new method for retrieving tropospheric NO(2) Vertical Column Density (VCD) from zenith-sky Differential Optical Absorption Spectroscopy (DOAS) measurements using mobile observations. This method was used during three days in the summer of 2011 in Romania, being to our know...

Descripción completa

Detalles Bibliográficos
Autores principales: Constantin, Daniel-Eduard, Merlaud, Alexis, Van Roozendael, Michel, Voiculescu, Mirela, Fayt, Caroline, Hendrick, François, Pinardi, Gaia, Georgescu, Lucian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658783/
https://www.ncbi.nlm.nih.gov/pubmed/23519349
http://dx.doi.org/10.3390/s130303922
_version_ 1782270333801201664
author Constantin, Daniel-Eduard
Merlaud, Alexis
Van Roozendael, Michel
Voiculescu, Mirela
Fayt, Caroline
Hendrick, François
Pinardi, Gaia
Georgescu, Lucian
author_facet Constantin, Daniel-Eduard
Merlaud, Alexis
Van Roozendael, Michel
Voiculescu, Mirela
Fayt, Caroline
Hendrick, François
Pinardi, Gaia
Georgescu, Lucian
author_sort Constantin, Daniel-Eduard
collection PubMed
description In this paper we present a new method for retrieving tropospheric NO(2) Vertical Column Density (VCD) from zenith-sky Differential Optical Absorption Spectroscopy (DOAS) measurements using mobile observations. This method was used during three days in the summer of 2011 in Romania, being to our knowledge the first mobile DOAS measurements peformed in this country. The measurements were carried out over large and different areas using a mobile DOAS system installed in a car. We present here a step-by-step retrieval of tropospheric VCD using complementary observations from ground and space which take into account the stratospheric contribution, which is a step forward compared to other similar studies. The detailed error budget indicates that the typical uncertainty on the retrieved NO(2)tropospheric VCD is less than 25%. The resulting ground-based data set is compared to satellite measurements from the Ozone Monitoring Instrument (OMI) and the Global Ozone Monitoring Experiment-2 (GOME-2). For instance, on 18 July 2011, in an industrial area located at 47.03°N, 22.45°E, GOME-2 observes a tropospheric VCD value of (3.4 ± 1.9) × 10(15) molec./cm(2), while average mobile measurements in the same area give a value of (3.4 ± 0.7) × 10(15) molec./cm(2). On 22 August 2011, around Ploiesti city (44.99°N, 26.1°E), the tropospheric VCD observed by satellites is (3.3 ± 1.9) × 10(15) molec./cm(2) (GOME-2) and (3.2 ± 3.2) × 10(15) molec./cm(2) (OMI), while average mobile measurements give (3.8 ± 0.8) × 10(15) molec./cm(2). Average ground measurements over “clean areas”, on 18 July 2011, give (2.5 ± 0.6) × 10(15) molec./cm(2) while the satellite observes a value of (1.8 ± 1.3) × 10(15) molec./cm(2).
format Online
Article
Text
id pubmed-3658783
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-36587832013-05-30 Measurements of Tropospheric NO(2) in Romania Using a Zenith-Sky Mobile DOAS System and Comparisons with Satellite Observations Constantin, Daniel-Eduard Merlaud, Alexis Van Roozendael, Michel Voiculescu, Mirela Fayt, Caroline Hendrick, François Pinardi, Gaia Georgescu, Lucian Sensors (Basel) Article In this paper we present a new method for retrieving tropospheric NO(2) Vertical Column Density (VCD) from zenith-sky Differential Optical Absorption Spectroscopy (DOAS) measurements using mobile observations. This method was used during three days in the summer of 2011 in Romania, being to our knowledge the first mobile DOAS measurements peformed in this country. The measurements were carried out over large and different areas using a mobile DOAS system installed in a car. We present here a step-by-step retrieval of tropospheric VCD using complementary observations from ground and space which take into account the stratospheric contribution, which is a step forward compared to other similar studies. The detailed error budget indicates that the typical uncertainty on the retrieved NO(2)tropospheric VCD is less than 25%. The resulting ground-based data set is compared to satellite measurements from the Ozone Monitoring Instrument (OMI) and the Global Ozone Monitoring Experiment-2 (GOME-2). For instance, on 18 July 2011, in an industrial area located at 47.03°N, 22.45°E, GOME-2 observes a tropospheric VCD value of (3.4 ± 1.9) × 10(15) molec./cm(2), while average mobile measurements in the same area give a value of (3.4 ± 0.7) × 10(15) molec./cm(2). On 22 August 2011, around Ploiesti city (44.99°N, 26.1°E), the tropospheric VCD observed by satellites is (3.3 ± 1.9) × 10(15) molec./cm(2) (GOME-2) and (3.2 ± 3.2) × 10(15) molec./cm(2) (OMI), while average mobile measurements give (3.8 ± 0.8) × 10(15) molec./cm(2). Average ground measurements over “clean areas”, on 18 July 2011, give (2.5 ± 0.6) × 10(15) molec./cm(2) while the satellite observes a value of (1.8 ± 1.3) × 10(15) molec./cm(2). Molecular Diversity Preservation International (MDPI) 2013-03-20 /pmc/articles/PMC3658783/ /pubmed/23519349 http://dx.doi.org/10.3390/s130303922 Text en © 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Constantin, Daniel-Eduard
Merlaud, Alexis
Van Roozendael, Michel
Voiculescu, Mirela
Fayt, Caroline
Hendrick, François
Pinardi, Gaia
Georgescu, Lucian
Measurements of Tropospheric NO(2) in Romania Using a Zenith-Sky Mobile DOAS System and Comparisons with Satellite Observations
title Measurements of Tropospheric NO(2) in Romania Using a Zenith-Sky Mobile DOAS System and Comparisons with Satellite Observations
title_full Measurements of Tropospheric NO(2) in Romania Using a Zenith-Sky Mobile DOAS System and Comparisons with Satellite Observations
title_fullStr Measurements of Tropospheric NO(2) in Romania Using a Zenith-Sky Mobile DOAS System and Comparisons with Satellite Observations
title_full_unstemmed Measurements of Tropospheric NO(2) in Romania Using a Zenith-Sky Mobile DOAS System and Comparisons with Satellite Observations
title_short Measurements of Tropospheric NO(2) in Romania Using a Zenith-Sky Mobile DOAS System and Comparisons with Satellite Observations
title_sort measurements of tropospheric no(2) in romania using a zenith-sky mobile doas system and comparisons with satellite observations
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658783/
https://www.ncbi.nlm.nih.gov/pubmed/23519349
http://dx.doi.org/10.3390/s130303922
work_keys_str_mv AT constantindanieleduard measurementsoftroposphericno2inromaniausingazenithskymobiledoassystemandcomparisonswithsatelliteobservations
AT merlaudalexis measurementsoftroposphericno2inromaniausingazenithskymobiledoassystemandcomparisonswithsatelliteobservations
AT vanroozendaelmichel measurementsoftroposphericno2inromaniausingazenithskymobiledoassystemandcomparisonswithsatelliteobservations
AT voiculescumirela measurementsoftroposphericno2inromaniausingazenithskymobiledoassystemandcomparisonswithsatelliteobservations
AT faytcaroline measurementsoftroposphericno2inromaniausingazenithskymobiledoassystemandcomparisonswithsatelliteobservations
AT hendrickfrancois measurementsoftroposphericno2inromaniausingazenithskymobiledoassystemandcomparisonswithsatelliteobservations
AT pinardigaia measurementsoftroposphericno2inromaniausingazenithskymobiledoassystemandcomparisonswithsatelliteobservations
AT georgesculucian measurementsoftroposphericno2inromaniausingazenithskymobiledoassystemandcomparisonswithsatelliteobservations