Cargando…
Ionizing irradiation affects the microtensile resin dentin bond strength under simulated clinical conditions
OBJECTIVES: This study evaluated the effect of ionizing radiations on resin–dentin interface in terms of marginal adaptation and micro-tensile bond strength under thermocycling and mechanical loading. MATERIALS AND METHODS: Forty extracted human mandibular third molars were divided into four groups....
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3659861/ https://www.ncbi.nlm.nih.gov/pubmed/23716968 http://dx.doi.org/10.4103/0972-0707.108198 |
_version_ | 1782270486226403328 |
---|---|
author | Yadav, Suman Yadav, Harish |
author_facet | Yadav, Suman Yadav, Harish |
author_sort | Yadav, Suman |
collection | PubMed |
description | OBJECTIVES: This study evaluated the effect of ionizing radiations on resin–dentin interface in terms of marginal adaptation and micro-tensile bond strength under thermocycling and mechanical loading. MATERIALS AND METHODS: Forty extracted human mandibular third molars were divided into four groups. GR I: No Irradiation and Class II MO cavities were prepared that were restored with composite restorations; GR II: Teeth were irradiated and restored; GR III: Teeth were restored and irradiated; GR IV: Teeth were restored during irradiation dosage fractions. All samples were thermal and mechanical loaded with 5000 cycles, 5 ± 2-55 ± 2°C, dwell time 30 s and 150,000 cycles at 60N. Resin–dentin slabs were trimmed into dumbbell-shaped slabs and microtensile bond strength was measured. The bond strength data was analyzed by one-way analysis of variance test. RESULTS AND CONCLUSIONS: Irradiation before tooth preparation deteriorated the microtensile bond strength. |
format | Online Article Text |
id | pubmed-3659861 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-36598612013-05-28 Ionizing irradiation affects the microtensile resin dentin bond strength under simulated clinical conditions Yadav, Suman Yadav, Harish J Conserv Dent Original Article OBJECTIVES: This study evaluated the effect of ionizing radiations on resin–dentin interface in terms of marginal adaptation and micro-tensile bond strength under thermocycling and mechanical loading. MATERIALS AND METHODS: Forty extracted human mandibular third molars were divided into four groups. GR I: No Irradiation and Class II MO cavities were prepared that were restored with composite restorations; GR II: Teeth were irradiated and restored; GR III: Teeth were restored and irradiated; GR IV: Teeth were restored during irradiation dosage fractions. All samples were thermal and mechanical loaded with 5000 cycles, 5 ± 2-55 ± 2°C, dwell time 30 s and 150,000 cycles at 60N. Resin–dentin slabs were trimmed into dumbbell-shaped slabs and microtensile bond strength was measured. The bond strength data was analyzed by one-way analysis of variance test. RESULTS AND CONCLUSIONS: Irradiation before tooth preparation deteriorated the microtensile bond strength. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3659861/ /pubmed/23716968 http://dx.doi.org/10.4103/0972-0707.108198 Text en Copyright: © Journal of Conservative Dentistry http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Yadav, Suman Yadav, Harish Ionizing irradiation affects the microtensile resin dentin bond strength under simulated clinical conditions |
title | Ionizing irradiation affects the microtensile resin dentin bond strength under simulated clinical conditions |
title_full | Ionizing irradiation affects the microtensile resin dentin bond strength under simulated clinical conditions |
title_fullStr | Ionizing irradiation affects the microtensile resin dentin bond strength under simulated clinical conditions |
title_full_unstemmed | Ionizing irradiation affects the microtensile resin dentin bond strength under simulated clinical conditions |
title_short | Ionizing irradiation affects the microtensile resin dentin bond strength under simulated clinical conditions |
title_sort | ionizing irradiation affects the microtensile resin dentin bond strength under simulated clinical conditions |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3659861/ https://www.ncbi.nlm.nih.gov/pubmed/23716968 http://dx.doi.org/10.4103/0972-0707.108198 |
work_keys_str_mv | AT yadavsuman ionizingirradiationaffectsthemicrotensileresindentinbondstrengthundersimulatedclinicalconditions AT yadavharish ionizingirradiationaffectsthemicrotensileresindentinbondstrengthundersimulatedclinicalconditions |