Cargando…

Ionizing irradiation affects the microtensile resin dentin bond strength under simulated clinical conditions

OBJECTIVES: This study evaluated the effect of ionizing radiations on resin–dentin interface in terms of marginal adaptation and micro-tensile bond strength under thermocycling and mechanical loading. MATERIALS AND METHODS: Forty extracted human mandibular third molars were divided into four groups....

Descripción completa

Detalles Bibliográficos
Autores principales: Yadav, Suman, Yadav, Harish
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3659861/
https://www.ncbi.nlm.nih.gov/pubmed/23716968
http://dx.doi.org/10.4103/0972-0707.108198
_version_ 1782270486226403328
author Yadav, Suman
Yadav, Harish
author_facet Yadav, Suman
Yadav, Harish
author_sort Yadav, Suman
collection PubMed
description OBJECTIVES: This study evaluated the effect of ionizing radiations on resin–dentin interface in terms of marginal adaptation and micro-tensile bond strength under thermocycling and mechanical loading. MATERIALS AND METHODS: Forty extracted human mandibular third molars were divided into four groups. GR I: No Irradiation and Class II MO cavities were prepared that were restored with composite restorations; GR II: Teeth were irradiated and restored; GR III: Teeth were restored and irradiated; GR IV: Teeth were restored during irradiation dosage fractions. All samples were thermal and mechanical loaded with 5000 cycles, 5 ± 2-55 ± 2°C, dwell time 30 s and 150,000 cycles at 60N. Resin–dentin slabs were trimmed into dumbbell-shaped slabs and microtensile bond strength was measured. The bond strength data was analyzed by one-way analysis of variance test. RESULTS AND CONCLUSIONS: Irradiation before tooth preparation deteriorated the microtensile bond strength.
format Online
Article
Text
id pubmed-3659861
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-36598612013-05-28 Ionizing irradiation affects the microtensile resin dentin bond strength under simulated clinical conditions Yadav, Suman Yadav, Harish J Conserv Dent Original Article OBJECTIVES: This study evaluated the effect of ionizing radiations on resin–dentin interface in terms of marginal adaptation and micro-tensile bond strength under thermocycling and mechanical loading. MATERIALS AND METHODS: Forty extracted human mandibular third molars were divided into four groups. GR I: No Irradiation and Class II MO cavities were prepared that were restored with composite restorations; GR II: Teeth were irradiated and restored; GR III: Teeth were restored and irradiated; GR IV: Teeth were restored during irradiation dosage fractions. All samples were thermal and mechanical loaded with 5000 cycles, 5 ± 2-55 ± 2°C, dwell time 30 s and 150,000 cycles at 60N. Resin–dentin slabs were trimmed into dumbbell-shaped slabs and microtensile bond strength was measured. The bond strength data was analyzed by one-way analysis of variance test. RESULTS AND CONCLUSIONS: Irradiation before tooth preparation deteriorated the microtensile bond strength. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3659861/ /pubmed/23716968 http://dx.doi.org/10.4103/0972-0707.108198 Text en Copyright: © Journal of Conservative Dentistry http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Yadav, Suman
Yadav, Harish
Ionizing irradiation affects the microtensile resin dentin bond strength under simulated clinical conditions
title Ionizing irradiation affects the microtensile resin dentin bond strength under simulated clinical conditions
title_full Ionizing irradiation affects the microtensile resin dentin bond strength under simulated clinical conditions
title_fullStr Ionizing irradiation affects the microtensile resin dentin bond strength under simulated clinical conditions
title_full_unstemmed Ionizing irradiation affects the microtensile resin dentin bond strength under simulated clinical conditions
title_short Ionizing irradiation affects the microtensile resin dentin bond strength under simulated clinical conditions
title_sort ionizing irradiation affects the microtensile resin dentin bond strength under simulated clinical conditions
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3659861/
https://www.ncbi.nlm.nih.gov/pubmed/23716968
http://dx.doi.org/10.4103/0972-0707.108198
work_keys_str_mv AT yadavsuman ionizingirradiationaffectsthemicrotensileresindentinbondstrengthundersimulatedclinicalconditions
AT yadavharish ionizingirradiationaffectsthemicrotensileresindentinbondstrengthundersimulatedclinicalconditions