Ultrasonographic Evaluation of Needle Insertion Site for the Flexor Pollicis Longus
OBJECTIVE: To establish the safest approach to needle electrode insertion into the flexor pollicis longus (FPL) regarding possible needle injury to the superficial radial nerve (SRN) or radial artery by ultrasonography. METHODS: We evaluated 54 forearms of 27 healthy subjects. Three levels were defi...
Autores principales: | Lee, Seung Min, Kim, Kihoon, Lee, Sang Min, Lee, Hyun Seok |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Rehabilitation Medicine
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3660482/ https://www.ncbi.nlm.nih.gov/pubmed/23705116 http://dx.doi.org/10.5535/arm.2013.37.2.215 |