Accuracy of CT cerebral perfusion in predicting infarct in the emergency department: lesion characterization on CT perfusion based on commercially available software

This study aims to assess the diagnostic accuracy of a single vendor commercially available CT perfusion (CTP) software in predicting stroke. A retrospective analysis on patients presenting with stroke-like symptoms within 6 h with CTP and diffusion-weighted imaging (DWI) was performed. Lesion maps,...

Descripción completa

Detalles Bibliográficos
Autores principales: Ho, Chang Y., Hussain, Sajjad, Alam, Tariq, Ahmad, Iftikhar, Wu, Isaac C., O’Neill, Darren P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer-Verlag 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3661911/
https://www.ncbi.nlm.nih.gov/pubmed/23322329
http://dx.doi.org/10.1007/s10140-012-1102-8
_version_ 1782270765904691200
author Ho, Chang Y.
Hussain, Sajjad
Alam, Tariq
Ahmad, Iftikhar
Wu, Isaac C.
O’Neill, Darren P.
author_facet Ho, Chang Y.
Hussain, Sajjad
Alam, Tariq
Ahmad, Iftikhar
Wu, Isaac C.
O’Neill, Darren P.
author_sort Ho, Chang Y.
collection PubMed
description This study aims to assess the diagnostic accuracy of a single vendor commercially available CT perfusion (CTP) software in predicting stroke. A retrospective analysis on patients presenting with stroke-like symptoms within 6 h with CTP and diffusion-weighted imaging (DWI) was performed. Lesion maps, which overlays areas of computer-detected abnormally elevated mean transit time (MTT) and decreased cerebral blood volume (CBV), were assessed from a commercially available software package and compared to qualitative interpretation of color maps. Using DWI as the gold standard, parameters of diagnostic accuracy were calculated. Point biserial correlation was performed to assess for relationship of lesion size to a true positive result. Sixty-five patients (41 females and 24 males, age range 22–92 years, mean 57) were included in the study. Twenty-two (34 %) had infarcts on DWI. Sensitivity (83 vs. 70 %), specificity (21 vs. 69 %), negative predictive value (77 vs. 84 %), and positive predictive value (29 vs. 50 %) for lesion maps were contrasted to qualitative interpretation of perfusion color maps, respectively. By using the lesion maps to exclude lesions detected qualitatively on color maps, specificity improved (80 %). Point biserial correlation for computer-generated lesions (R (pb) = 0.46, p < 0.0001) and lesions detected qualitatively (R (pb) = 0.32, p = 0.0016) demonstrated positive correlation between size and infarction. Seventy-three percent (p = 0.018) of lesions which demonstrated an increasing size from CBV, cerebral blood flow, to MTT/time to peak were true positive. Used in isolation, computer-generated lesion maps in CTP provide limited diagnostic utility in predicting infarct, due to their inherently low specificity. However, when used in conjunction with qualitative perfusion color map assessment, the lesion maps can help improve specificity.
format Online
Article
Text
id pubmed-3661911
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-36619112013-05-23 Accuracy of CT cerebral perfusion in predicting infarct in the emergency department: lesion characterization on CT perfusion based on commercially available software Ho, Chang Y. Hussain, Sajjad Alam, Tariq Ahmad, Iftikhar Wu, Isaac C. O’Neill, Darren P. Emerg Radiol Original Article This study aims to assess the diagnostic accuracy of a single vendor commercially available CT perfusion (CTP) software in predicting stroke. A retrospective analysis on patients presenting with stroke-like symptoms within 6 h with CTP and diffusion-weighted imaging (DWI) was performed. Lesion maps, which overlays areas of computer-detected abnormally elevated mean transit time (MTT) and decreased cerebral blood volume (CBV), were assessed from a commercially available software package and compared to qualitative interpretation of color maps. Using DWI as the gold standard, parameters of diagnostic accuracy were calculated. Point biserial correlation was performed to assess for relationship of lesion size to a true positive result. Sixty-five patients (41 females and 24 males, age range 22–92 years, mean 57) were included in the study. Twenty-two (34 %) had infarcts on DWI. Sensitivity (83 vs. 70 %), specificity (21 vs. 69 %), negative predictive value (77 vs. 84 %), and positive predictive value (29 vs. 50 %) for lesion maps were contrasted to qualitative interpretation of perfusion color maps, respectively. By using the lesion maps to exclude lesions detected qualitatively on color maps, specificity improved (80 %). Point biserial correlation for computer-generated lesions (R (pb) = 0.46, p < 0.0001) and lesions detected qualitatively (R (pb) = 0.32, p = 0.0016) demonstrated positive correlation between size and infarction. Seventy-three percent (p = 0.018) of lesions which demonstrated an increasing size from CBV, cerebral blood flow, to MTT/time to peak were true positive. Used in isolation, computer-generated lesion maps in CTP provide limited diagnostic utility in predicting infarct, due to their inherently low specificity. However, when used in conjunction with qualitative perfusion color map assessment, the lesion maps can help improve specificity. Springer-Verlag 2013-01-16 2013 /pmc/articles/PMC3661911/ /pubmed/23322329 http://dx.doi.org/10.1007/s10140-012-1102-8 Text en © The Author(s) 2013 https://creativecommons.org/licenses/by/2.0/ Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Original Article
Ho, Chang Y.
Hussain, Sajjad
Alam, Tariq
Ahmad, Iftikhar
Wu, Isaac C.
O’Neill, Darren P.
Accuracy of CT cerebral perfusion in predicting infarct in the emergency department: lesion characterization on CT perfusion based on commercially available software
title Accuracy of CT cerebral perfusion in predicting infarct in the emergency department: lesion characterization on CT perfusion based on commercially available software
title_full Accuracy of CT cerebral perfusion in predicting infarct in the emergency department: lesion characterization on CT perfusion based on commercially available software
title_fullStr Accuracy of CT cerebral perfusion in predicting infarct in the emergency department: lesion characterization on CT perfusion based on commercially available software
title_full_unstemmed Accuracy of CT cerebral perfusion in predicting infarct in the emergency department: lesion characterization on CT perfusion based on commercially available software
title_short Accuracy of CT cerebral perfusion in predicting infarct in the emergency department: lesion characterization on CT perfusion based on commercially available software
title_sort accuracy of ct cerebral perfusion in predicting infarct in the emergency department: lesion characterization on ct perfusion based on commercially available software
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3661911/
https://www.ncbi.nlm.nih.gov/pubmed/23322329
http://dx.doi.org/10.1007/s10140-012-1102-8
work_keys_str_mv AT hochangy accuracyofctcerebralperfusioninpredictinginfarctintheemergencydepartmentlesioncharacterizationonctperfusionbasedoncommerciallyavailablesoftware
AT hussainsajjad accuracyofctcerebralperfusioninpredictinginfarctintheemergencydepartmentlesioncharacterizationonctperfusionbasedoncommerciallyavailablesoftware
AT alamtariq accuracyofctcerebralperfusioninpredictinginfarctintheemergencydepartmentlesioncharacterizationonctperfusionbasedoncommerciallyavailablesoftware
AT ahmadiftikhar accuracyofctcerebralperfusioninpredictinginfarctintheemergencydepartmentlesioncharacterizationonctperfusionbasedoncommerciallyavailablesoftware
AT wuisaacc accuracyofctcerebralperfusioninpredictinginfarctintheemergencydepartmentlesioncharacterizationonctperfusionbasedoncommerciallyavailablesoftware
AT oneilldarrenp accuracyofctcerebralperfusioninpredictinginfarctintheemergencydepartmentlesioncharacterizationonctperfusionbasedoncommerciallyavailablesoftware