Cargando…

The Magnitude of Errors Associated in Measuring the Loads Applied on an Assistive Device While Walking

Measurement of the loads exerted on the limb is a fundamental part of designing of an assistive device, which has been done by using strain gauges or a transducer. Although calculation of loads applied on an orthosis coefficients achieved from calibration is a standard way, most of researchers deter...

Descripción completa

Detalles Bibliográficos
Autores principales: Karimi, Mohammad Taghi, Jamshidi, Nima
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3662106/
https://www.ncbi.nlm.nih.gov/pubmed/23724373
_version_ 1782270800617799680
author Karimi, Mohammad Taghi
Jamshidi, Nima
author_facet Karimi, Mohammad Taghi
Jamshidi, Nima
author_sort Karimi, Mohammad Taghi
collection PubMed
description Measurement of the loads exerted on the limb is a fundamental part of designing of an assistive device, which has been done by using strain gauges or a transducer. Although calculation of loads applied on an orthosis coefficients achieved from calibration is a standard way, most of researchers determined the loads based on available equations. Therefore, the aim of this research is finding the accuracy of this method with respect to calibration. Some strain gauges were attached on the lateral bar of a reciprocal gait orthosis. It was calibrated for axial force and the anteroposterior and mediolateral moments. The outputs of strain gauge were changed to force, and moments based on the coefficients were achieved from calibration using available equations, while 5 normal subjects were walking with the orthosis. There was a significant difference between the force and moments exerted on the orthosis during walking based on the two methods (mostly extension moment and compression force). The results of this research indicated that the output of strain gauge varies based on the methods of calculation. As calibration the gauge is a standard method, it is recommended to calibrate it before use.
format Online
Article
Text
id pubmed-3662106
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-36621062013-05-30 The Magnitude of Errors Associated in Measuring the Loads Applied on an Assistive Device While Walking Karimi, Mohammad Taghi Jamshidi, Nima J Med Signals Sens Original Article Measurement of the loads exerted on the limb is a fundamental part of designing of an assistive device, which has been done by using strain gauges or a transducer. Although calculation of loads applied on an orthosis coefficients achieved from calibration is a standard way, most of researchers determined the loads based on available equations. Therefore, the aim of this research is finding the accuracy of this method with respect to calibration. Some strain gauges were attached on the lateral bar of a reciprocal gait orthosis. It was calibrated for axial force and the anteroposterior and mediolateral moments. The outputs of strain gauge were changed to force, and moments based on the coefficients were achieved from calibration using available equations, while 5 normal subjects were walking with the orthosis. There was a significant difference between the force and moments exerted on the orthosis during walking based on the two methods (mostly extension moment and compression force). The results of this research indicated that the output of strain gauge varies based on the methods of calculation. As calibration the gauge is a standard method, it is recommended to calibrate it before use. Medknow Publications & Media Pvt Ltd 2012 /pmc/articles/PMC3662106/ /pubmed/23724373 Text en Copyright: © Journal of Medical Signals and Sensors http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Karimi, Mohammad Taghi
Jamshidi, Nima
The Magnitude of Errors Associated in Measuring the Loads Applied on an Assistive Device While Walking
title The Magnitude of Errors Associated in Measuring the Loads Applied on an Assistive Device While Walking
title_full The Magnitude of Errors Associated in Measuring the Loads Applied on an Assistive Device While Walking
title_fullStr The Magnitude of Errors Associated in Measuring the Loads Applied on an Assistive Device While Walking
title_full_unstemmed The Magnitude of Errors Associated in Measuring the Loads Applied on an Assistive Device While Walking
title_short The Magnitude of Errors Associated in Measuring the Loads Applied on an Assistive Device While Walking
title_sort magnitude of errors associated in measuring the loads applied on an assistive device while walking
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3662106/
https://www.ncbi.nlm.nih.gov/pubmed/23724373
work_keys_str_mv AT karimimohammadtaghi themagnitudeoferrorsassociatedinmeasuringtheloadsappliedonanassistivedevicewhilewalking
AT jamshidinima themagnitudeoferrorsassociatedinmeasuringtheloadsappliedonanassistivedevicewhilewalking
AT karimimohammadtaghi magnitudeoferrorsassociatedinmeasuringtheloadsappliedonanassistivedevicewhilewalking
AT jamshidinima magnitudeoferrorsassociatedinmeasuringtheloadsappliedonanassistivedevicewhilewalking