Cargando…

Horizontal Running Mattress Suture Modified with Intermittent Simple Loops

Using the combination of a horizontal running mattress suture with intermittent loops achieves both good eversion with the horizontal running mattress plus the ease of removal of the simple loops. This combination technique also avoids the characteristic railroad track marks that result from prolong...

Descripción completa

Detalles Bibliográficos
Autores principales: Chacon, Anna H, Shiman, Michael I, Strozier, Narissa, Zaiac, Martin N
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3663182/
https://www.ncbi.nlm.nih.gov/pubmed/23723610
http://dx.doi.org/10.4103/0974-2077.110102
_version_ 1782270947505471488
author Chacon, Anna H
Shiman, Michael I
Strozier, Narissa
Zaiac, Martin N
author_facet Chacon, Anna H
Shiman, Michael I
Strozier, Narissa
Zaiac, Martin N
author_sort Chacon, Anna H
collection PubMed
description Using the combination of a horizontal running mattress suture with intermittent loops achieves both good eversion with the horizontal running mattress plus the ease of removal of the simple loops. This combination technique also avoids the characteristic railroad track marks that result from prolonged non-absorbable suture retention. The unique feature of our technique is the incorporation of one simple running suture after every two runs of the horizontal running mattress suture. To demonstrate its utility, we used the suturing technique on several patients and analyzed the cosmetic outcome with post-operative photographs in comparison to other suturing techniques. In summary, the combination of running horizontal mattress suture with simple intermittent loops demonstrates functional and cosmetic benefits that can be readily taught, comprehended, and employed, leading to desirable aesthetic results and wound edge eversion.
format Online
Article
Text
id pubmed-3663182
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-36631822013-05-30 Horizontal Running Mattress Suture Modified with Intermittent Simple Loops Chacon, Anna H Shiman, Michael I Strozier, Narissa Zaiac, Martin N J Cutan Aesthet Surg Surgical Pearl Using the combination of a horizontal running mattress suture with intermittent loops achieves both good eversion with the horizontal running mattress plus the ease of removal of the simple loops. This combination technique also avoids the characteristic railroad track marks that result from prolonged non-absorbable suture retention. The unique feature of our technique is the incorporation of one simple running suture after every two runs of the horizontal running mattress suture. To demonstrate its utility, we used the suturing technique on several patients and analyzed the cosmetic outcome with post-operative photographs in comparison to other suturing techniques. In summary, the combination of running horizontal mattress suture with simple intermittent loops demonstrates functional and cosmetic benefits that can be readily taught, comprehended, and employed, leading to desirable aesthetic results and wound edge eversion. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3663182/ /pubmed/23723610 http://dx.doi.org/10.4103/0974-2077.110102 Text en Copyright: © Journal of Cutaneous and Aesthetic Surgery http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Surgical Pearl
Chacon, Anna H
Shiman, Michael I
Strozier, Narissa
Zaiac, Martin N
Horizontal Running Mattress Suture Modified with Intermittent Simple Loops
title Horizontal Running Mattress Suture Modified with Intermittent Simple Loops
title_full Horizontal Running Mattress Suture Modified with Intermittent Simple Loops
title_fullStr Horizontal Running Mattress Suture Modified with Intermittent Simple Loops
title_full_unstemmed Horizontal Running Mattress Suture Modified with Intermittent Simple Loops
title_short Horizontal Running Mattress Suture Modified with Intermittent Simple Loops
title_sort horizontal running mattress suture modified with intermittent simple loops
topic Surgical Pearl
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3663182/
https://www.ncbi.nlm.nih.gov/pubmed/23723610
http://dx.doi.org/10.4103/0974-2077.110102
work_keys_str_mv AT chaconannah horizontalrunningmattresssuturemodifiedwithintermittentsimpleloops
AT shimanmichaeli horizontalrunningmattresssuturemodifiedwithintermittentsimpleloops
AT stroziernarissa horizontalrunningmattresssuturemodifiedwithintermittentsimpleloops
AT zaiacmartinn horizontalrunningmattresssuturemodifiedwithintermittentsimpleloops