Cargando…

Functionality and Safety of an Ultra-Congruent Rotating Platform Knee Prosthesis at 5.6 Years: More than 5- Year Follow-Up of the e.motion((®)) UC-TKA

BACKGROUND: Mobile bearing TKA prostheses were designed to minimize polyethylene wear by increasing implant conformity and reducing stresses between the articulating prosthesis components. It is the purpose of this study to assess the mid-term functionality and clinical outcome associated with a hig...

Descripción completa

Detalles Bibliográficos
Autor principal: Chavoix, Jean-Baptiste
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bentham Open 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3664449/
https://www.ncbi.nlm.nih.gov/pubmed/23730378
http://dx.doi.org/10.2174/1874325001307010152
_version_ 1782271103425576960
author Chavoix, Jean-Baptiste
author_facet Chavoix, Jean-Baptiste
author_sort Chavoix, Jean-Baptiste
collection PubMed
description BACKGROUND: Mobile bearing TKA prostheses were designed to minimize polyethylene wear by increasing implant conformity and reducing stresses between the articulating prosthesis components. It is the purpose of this study to assess the mid-term functionality and clinical outcome associated with a highly congruent mobile platform design, the e.motion(®) UC total knee prosthesis. MATERIAL AND METHODS: Functional and clinical outcomes were assessed after an average of 5.6 years (5.1 – 6.0 years) after total knee arthroplasty in 28 patients (24 women), aged 77.8±7.5 years. The Knee injury and Osteoarthritis Outcome Score (KOOS) was assessed. Secondary outcomes included the Knee Society Score (KSS), radiological evaluation of radiolucent lines and recording of adverse events. RESULTS: The average KOOS subscore for the activities of daily life was 77.8 points after 5.6 years. Both the clinical and functional KSS improved at 2.4 and 5.6 years. Two patients showed radiolucent lines at 5.6 years. Adverse events over 5.6 years included 3 subluxations, 1 tilting and 1 misalignment of the patella. None of the prostheses were revised. CONCLUSION: This pilot study shows promising outcomes for the e.motion(®) UC prosthesis. In the small sample, the implant performed comparably to the LCS prosthesis (the gold standard). There were no loosenings or revisions observed at 5.6 years.
format Online
Article
Text
id pubmed-3664449
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Bentham Open
record_format MEDLINE/PubMed
spelling pubmed-36644492013-05-31 Functionality and Safety of an Ultra-Congruent Rotating Platform Knee Prosthesis at 5.6 Years: More than 5- Year Follow-Up of the e.motion((®)) UC-TKA Chavoix, Jean-Baptiste Open Orthop J Article BACKGROUND: Mobile bearing TKA prostheses were designed to minimize polyethylene wear by increasing implant conformity and reducing stresses between the articulating prosthesis components. It is the purpose of this study to assess the mid-term functionality and clinical outcome associated with a highly congruent mobile platform design, the e.motion(®) UC total knee prosthesis. MATERIAL AND METHODS: Functional and clinical outcomes were assessed after an average of 5.6 years (5.1 – 6.0 years) after total knee arthroplasty in 28 patients (24 women), aged 77.8±7.5 years. The Knee injury and Osteoarthritis Outcome Score (KOOS) was assessed. Secondary outcomes included the Knee Society Score (KSS), radiological evaluation of radiolucent lines and recording of adverse events. RESULTS: The average KOOS subscore for the activities of daily life was 77.8 points after 5.6 years. Both the clinical and functional KSS improved at 2.4 and 5.6 years. Two patients showed radiolucent lines at 5.6 years. Adverse events over 5.6 years included 3 subluxations, 1 tilting and 1 misalignment of the patella. None of the prostheses were revised. CONCLUSION: This pilot study shows promising outcomes for the e.motion(®) UC prosthesis. In the small sample, the implant performed comparably to the LCS prosthesis (the gold standard). There were no loosenings or revisions observed at 5.6 years. Bentham Open 2013-05-17 /pmc/articles/PMC3664449/ /pubmed/23730378 http://dx.doi.org/10.2174/1874325001307010152 Text en © Jean-Baptiste Chavoix; Licensee Bentham Open. http://creativecommons.org/licenses/by-nc/3.0/ This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.
spellingShingle Article
Chavoix, Jean-Baptiste
Functionality and Safety of an Ultra-Congruent Rotating Platform Knee Prosthesis at 5.6 Years: More than 5- Year Follow-Up of the e.motion((®)) UC-TKA
title Functionality and Safety of an Ultra-Congruent Rotating Platform Knee Prosthesis at 5.6 Years: More than 5- Year Follow-Up of the e.motion((®)) UC-TKA
title_full Functionality and Safety of an Ultra-Congruent Rotating Platform Knee Prosthesis at 5.6 Years: More than 5- Year Follow-Up of the e.motion((®)) UC-TKA
title_fullStr Functionality and Safety of an Ultra-Congruent Rotating Platform Knee Prosthesis at 5.6 Years: More than 5- Year Follow-Up of the e.motion((®)) UC-TKA
title_full_unstemmed Functionality and Safety of an Ultra-Congruent Rotating Platform Knee Prosthesis at 5.6 Years: More than 5- Year Follow-Up of the e.motion((®)) UC-TKA
title_short Functionality and Safety of an Ultra-Congruent Rotating Platform Knee Prosthesis at 5.6 Years: More than 5- Year Follow-Up of the e.motion((®)) UC-TKA
title_sort functionality and safety of an ultra-congruent rotating platform knee prosthesis at 5.6 years: more than 5- year follow-up of the e.motion((®)) uc-tka
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3664449/
https://www.ncbi.nlm.nih.gov/pubmed/23730378
http://dx.doi.org/10.2174/1874325001307010152
work_keys_str_mv AT chavoixjeanbaptiste functionalityandsafetyofanultracongruentrotatingplatformkneeprosthesisat56yearsmorethan5yearfollowupoftheemotionuctka