Cargando…

Spreadsheet program for estimating recovery coefficient to get partial volume corrected standardized uptake value in clinical positron emission tomography-computed tomography studies

PURPOSE: To develop a spreadsheet program for estimation of recovery coefficient (RC) to get partial volume corrected (PVC) standardized uptake value (SUV) in clinical positron emission tomography-computed tomography (PET-CT) studies. MATERIALS AND METHODS: For formulation of this program we used da...

Descripción completa

Detalles Bibliográficos
Autores principales: Pandey, Anil Kumar, Sharma, Punit, Pandey, Manjesh, Aswathi, KK, Malhotra, Arun, Kumar, Rakesh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3665153/
https://www.ncbi.nlm.nih.gov/pubmed/23723579
http://dx.doi.org/10.4103/0972-3919.110688
_version_ 1782271219055198208
author Pandey, Anil Kumar
Sharma, Punit
Pandey, Manjesh
Aswathi, KK
Malhotra, Arun
Kumar, Rakesh
author_facet Pandey, Anil Kumar
Sharma, Punit
Pandey, Manjesh
Aswathi, KK
Malhotra, Arun
Kumar, Rakesh
author_sort Pandey, Anil Kumar
collection PubMed
description PURPOSE: To develop a spreadsheet program for estimation of recovery coefficient (RC) to get partial volume corrected (PVC) standardized uptake value (SUV) in clinical positron emission tomography-computed tomography (PET-CT) studies. MATERIALS AND METHODS: For formulation of this program we used data from a phantom study conducted at our center in which a phantom with a sphere assembly (seven spheres-different diameters) was filled with 18F-Fluorodeoxyglucose solution to get a sphere/background ratio of 8:1, 10:1 and 12:1. PET-CT images were acquired. RC was then calculated from processed PET-CT images. We plotted graph of RC versus lesion-size at different sphere/background ratio using MS Excel function. There was logarithmic increase in RC with increase in lesion size. We fitted the data with a logarithmic equation and found optimum fit (least-square fit). We then validated this program with clinical data using 42 lung nodules in five patients. RESULTS: The program estimates the value of RC and object to background ratio in PET-CT for the input lesion-size and displays graph with trendline. When the user enters SUV and background activity measured in clinical PET-CT, it provides the value of RC and PVC SUV. It also validates the data entry and displays appropriate message. It is consistent, reproducible, accurate and provides output for wide range of lesion-sizes (71% of lesions evaluated); however, program does not give output for lesion-size < 9 mm. CONCLUSION: The present spreadsheet program is a useful and easy tool for calculating PVC SUV of clinical PET-CT lesions.
format Online
Article
Text
id pubmed-3665153
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-36651532013-05-30 Spreadsheet program for estimating recovery coefficient to get partial volume corrected standardized uptake value in clinical positron emission tomography-computed tomography studies Pandey, Anil Kumar Sharma, Punit Pandey, Manjesh Aswathi, KK Malhotra, Arun Kumar, Rakesh Indian J Nucl Med Original Article PURPOSE: To develop a spreadsheet program for estimation of recovery coefficient (RC) to get partial volume corrected (PVC) standardized uptake value (SUV) in clinical positron emission tomography-computed tomography (PET-CT) studies. MATERIALS AND METHODS: For formulation of this program we used data from a phantom study conducted at our center in which a phantom with a sphere assembly (seven spheres-different diameters) was filled with 18F-Fluorodeoxyglucose solution to get a sphere/background ratio of 8:1, 10:1 and 12:1. PET-CT images were acquired. RC was then calculated from processed PET-CT images. We plotted graph of RC versus lesion-size at different sphere/background ratio using MS Excel function. There was logarithmic increase in RC with increase in lesion size. We fitted the data with a logarithmic equation and found optimum fit (least-square fit). We then validated this program with clinical data using 42 lung nodules in five patients. RESULTS: The program estimates the value of RC and object to background ratio in PET-CT for the input lesion-size and displays graph with trendline. When the user enters SUV and background activity measured in clinical PET-CT, it provides the value of RC and PVC SUV. It also validates the data entry and displays appropriate message. It is consistent, reproducible, accurate and provides output for wide range of lesion-sizes (71% of lesions evaluated); however, program does not give output for lesion-size < 9 mm. CONCLUSION: The present spreadsheet program is a useful and easy tool for calculating PVC SUV of clinical PET-CT lesions. Medknow Publications & Media Pvt Ltd 2012 /pmc/articles/PMC3665153/ /pubmed/23723579 http://dx.doi.org/10.4103/0972-3919.110688 Text en Copyright: © Indian Journal of Nuclear Medicine http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Pandey, Anil Kumar
Sharma, Punit
Pandey, Manjesh
Aswathi, KK
Malhotra, Arun
Kumar, Rakesh
Spreadsheet program for estimating recovery coefficient to get partial volume corrected standardized uptake value in clinical positron emission tomography-computed tomography studies
title Spreadsheet program for estimating recovery coefficient to get partial volume corrected standardized uptake value in clinical positron emission tomography-computed tomography studies
title_full Spreadsheet program for estimating recovery coefficient to get partial volume corrected standardized uptake value in clinical positron emission tomography-computed tomography studies
title_fullStr Spreadsheet program for estimating recovery coefficient to get partial volume corrected standardized uptake value in clinical positron emission tomography-computed tomography studies
title_full_unstemmed Spreadsheet program for estimating recovery coefficient to get partial volume corrected standardized uptake value in clinical positron emission tomography-computed tomography studies
title_short Spreadsheet program for estimating recovery coefficient to get partial volume corrected standardized uptake value in clinical positron emission tomography-computed tomography studies
title_sort spreadsheet program for estimating recovery coefficient to get partial volume corrected standardized uptake value in clinical positron emission tomography-computed tomography studies
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3665153/
https://www.ncbi.nlm.nih.gov/pubmed/23723579
http://dx.doi.org/10.4103/0972-3919.110688
work_keys_str_mv AT pandeyanilkumar spreadsheetprogramforestimatingrecoverycoefficienttogetpartialvolumecorrectedstandardizeduptakevalueinclinicalpositronemissiontomographycomputedtomographystudies
AT sharmapunit spreadsheetprogramforestimatingrecoverycoefficienttogetpartialvolumecorrectedstandardizeduptakevalueinclinicalpositronemissiontomographycomputedtomographystudies
AT pandeymanjesh spreadsheetprogramforestimatingrecoverycoefficienttogetpartialvolumecorrectedstandardizeduptakevalueinclinicalpositronemissiontomographycomputedtomographystudies
AT aswathikk spreadsheetprogramforestimatingrecoverycoefficienttogetpartialvolumecorrectedstandardizeduptakevalueinclinicalpositronemissiontomographycomputedtomographystudies
AT malhotraarun spreadsheetprogramforestimatingrecoverycoefficienttogetpartialvolumecorrectedstandardizeduptakevalueinclinicalpositronemissiontomographycomputedtomographystudies
AT kumarrakesh spreadsheetprogramforestimatingrecoverycoefficienttogetpartialvolumecorrectedstandardizeduptakevalueinclinicalpositronemissiontomographycomputedtomographystudies