Cargando…
Accuracy and precision of cap thickness in small incision lenticule extraction
AIMS: To report and compare the cap thickness predictability of small incision lenticule extraction (SMILE) and flap thickness of femtosecond laser-assisted in situ keratomileusis (femto-LASIK). SETTINGS AND DESIGN: Beyoglu Eye Training and Research Hospital, Refractive Surgery Department, Istanbul,...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3665570/ https://www.ncbi.nlm.nih.gov/pubmed/23723683 http://dx.doi.org/10.2147/OPTH.S45227 |
_version_ | 1782271274019454976 |
---|---|
author | Ozgurhan, Engin Bilge Agca, Alper Bozkurt, Ercument Gencer, Baran Celik, Ugur Cankaya, Kadir Ilker Demirok, Ahmet Yilmaz, Omer Faruk |
author_facet | Ozgurhan, Engin Bilge Agca, Alper Bozkurt, Ercument Gencer, Baran Celik, Ugur Cankaya, Kadir Ilker Demirok, Ahmet Yilmaz, Omer Faruk |
author_sort | Ozgurhan, Engin Bilge |
collection | PubMed |
description | AIMS: To report and compare the cap thickness predictability of small incision lenticule extraction (SMILE) and flap thickness of femtosecond laser-assisted in situ keratomileusis (femto-LASIK). SETTINGS AND DESIGN: Beyoglu Eye Training and Research Hospital, Refractive Surgery Department, Istanbul, Turkey. Retrospective pilot study. MATERIALS AND METHODS: Medical records of patients who had SMILE in one eye and femto-LASIK in the other eye were reviewed. Visante corneal Optical Coherence Tomography (OCT) images at 1 week and 1 month post-surgery were analyzed. Both cap and flap thickness at the temporal edge and the nasal edge were measured and compared to each other. STATISTICAL ANALYSES USED: PAWS Statistics 18 and unpaired student t-test were used to compare the groups. RESULTS: The study included 66 eyes of 33 patients (24.7 ± 3.8 years, 20 females and 13 males). Mean flap thickness was 114.88 μm ± 4.96 μm, and mean cap thickness was 114.63 μm ± 5.18 μm. In group 1 (SMILE), cap thickness values were 115.84 μm ± 6.84 μm, 114.75 μm ± 7.36 μm, 113.66 μm ± 6.88 μm, and 114.27 μm ± 6.90 μm in measurement zones 1, 2, 3, and 4, respectively. In group 2 (FemtoLASIK), flap corneal thickness values were 115.96 mmHg ± 7.01 mmHg, 114.72 mmHg ± 7.17 mmHg, 113.54 mmHg ± 6.45 mmHg, and 115.30 mmHg ± 6.64 mmHg in measurement zones 1, 2, 3, and 4, respectively. In both groups, no statistically significant change within the measurement zones was observed. CONCLUSION: The predictability of cap thickness in SMILE surgery does not differ from the femto-LASIK flaps created using the same femtosecond laser platform. |
format | Online Article Text |
id | pubmed-3665570 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-36655702013-05-30 Accuracy and precision of cap thickness in small incision lenticule extraction Ozgurhan, Engin Bilge Agca, Alper Bozkurt, Ercument Gencer, Baran Celik, Ugur Cankaya, Kadir Ilker Demirok, Ahmet Yilmaz, Omer Faruk Clin Ophthalmol Original Research AIMS: To report and compare the cap thickness predictability of small incision lenticule extraction (SMILE) and flap thickness of femtosecond laser-assisted in situ keratomileusis (femto-LASIK). SETTINGS AND DESIGN: Beyoglu Eye Training and Research Hospital, Refractive Surgery Department, Istanbul, Turkey. Retrospective pilot study. MATERIALS AND METHODS: Medical records of patients who had SMILE in one eye and femto-LASIK in the other eye were reviewed. Visante corneal Optical Coherence Tomography (OCT) images at 1 week and 1 month post-surgery were analyzed. Both cap and flap thickness at the temporal edge and the nasal edge were measured and compared to each other. STATISTICAL ANALYSES USED: PAWS Statistics 18 and unpaired student t-test were used to compare the groups. RESULTS: The study included 66 eyes of 33 patients (24.7 ± 3.8 years, 20 females and 13 males). Mean flap thickness was 114.88 μm ± 4.96 μm, and mean cap thickness was 114.63 μm ± 5.18 μm. In group 1 (SMILE), cap thickness values were 115.84 μm ± 6.84 μm, 114.75 μm ± 7.36 μm, 113.66 μm ± 6.88 μm, and 114.27 μm ± 6.90 μm in measurement zones 1, 2, 3, and 4, respectively. In group 2 (FemtoLASIK), flap corneal thickness values were 115.96 mmHg ± 7.01 mmHg, 114.72 mmHg ± 7.17 mmHg, 113.54 mmHg ± 6.45 mmHg, and 115.30 mmHg ± 6.64 mmHg in measurement zones 1, 2, 3, and 4, respectively. In both groups, no statistically significant change within the measurement zones was observed. CONCLUSION: The predictability of cap thickness in SMILE surgery does not differ from the femto-LASIK flaps created using the same femtosecond laser platform. Dove Medical Press 2013 2013-05-21 /pmc/articles/PMC3665570/ /pubmed/23723683 http://dx.doi.org/10.2147/OPTH.S45227 Text en © 2013 Ozgurhan et al, publisher and licensee Dove Medical Press Ltd. This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited. |
spellingShingle | Original Research Ozgurhan, Engin Bilge Agca, Alper Bozkurt, Ercument Gencer, Baran Celik, Ugur Cankaya, Kadir Ilker Demirok, Ahmet Yilmaz, Omer Faruk Accuracy and precision of cap thickness in small incision lenticule extraction |
title | Accuracy and precision of cap thickness in small incision lenticule extraction |
title_full | Accuracy and precision of cap thickness in small incision lenticule extraction |
title_fullStr | Accuracy and precision of cap thickness in small incision lenticule extraction |
title_full_unstemmed | Accuracy and precision of cap thickness in small incision lenticule extraction |
title_short | Accuracy and precision of cap thickness in small incision lenticule extraction |
title_sort | accuracy and precision of cap thickness in small incision lenticule extraction |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3665570/ https://www.ncbi.nlm.nih.gov/pubmed/23723683 http://dx.doi.org/10.2147/OPTH.S45227 |
work_keys_str_mv | AT ozgurhanenginbilge accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction AT agcaalper accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction AT bozkurtercument accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction AT gencerbaran accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction AT celikugur accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction AT cankayakadirilker accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction AT demirokahmet accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction AT yilmazomerfaruk accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction |