Cargando…

Estimate of nocturnal blood pressure and detection of non-dippers based on clinical or ambulatory monitoring in the inpatient setting

BACKGROUND: Ambulatory blood pressure monitoring is regarded as the gold standard for monitoring nocturnal blood pressure (NBP) and is usually performed out of office. Currently, a novel method for monitoring NBP is indispensible in the inpatient setting. The widely used manual BP monitoring procedu...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Tan, Zhang, Yongqing, Tan, Xuerui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3665662/
https://www.ncbi.nlm.nih.gov/pubmed/23692688
http://dx.doi.org/10.1186/1471-2261-13-37
_version_ 1782271285721563136
author Xu, Tan
Zhang, Yongqing
Tan, Xuerui
author_facet Xu, Tan
Zhang, Yongqing
Tan, Xuerui
author_sort Xu, Tan
collection PubMed
description BACKGROUND: Ambulatory blood pressure monitoring is regarded as the gold standard for monitoring nocturnal blood pressure (NBP) and is usually performed out of office. Currently, a novel method for monitoring NBP is indispensible in the inpatient setting. The widely used manual BP monitoring procedure has the potential to monitor NBP in the hospital setting. The feasibility and accuracy of manual sphygmomanometer to monitor NBP has not been explored widely. METHODS: A cross-sectional study was conducted at the cardiology department of a university-affiliated hospital to study patients with mild-to-moderate essential hypertension. One hundred and fifty-five patients were recruited to compare BP derived from a manual device and ambulatory BP monitoring (ABPM). The manual BP measurement was performed six times at 22:00, 02:00, 06:00, 10:00, 14:00 and 18:00 h. The measurements at 22:00, 02:00 and 06:00 h were defined as night-time and the others as daytime. ABPM was programmed to measure at 30-min intervals between measurements. RESULTS: All-day, daytime and night-time BP did not differ significantly from 24-h ambulatory systolic BP [all-day mean difference −0.52±4.67 mmHg, 95% confidence interval (CI) –1.26 to 0.22, P=0.168; daytime mean difference 0.24±5.45 mmHg, 95% CI −0.62 to 1.11, P=0.580; night-time mean difference 0.30±7.22 mmHg, 95% CI −0.84 to 1.45, P=0.601) rather than diastolic BP. There was a strong correlation between clinical and ambulatory BP for both systolic and diastolic BP. On the basis of ABPM, 101 (65%) patients were classified as non-dippers, compared with 106 (68%) by manual sphygmomanometer (P<0.001). CONCLUSIONS: Traditional manual sphygmomanometer provides similar daytime and night-time systolic BP measurements in hospital. Moreover, the detection of non-dippers by manual methods is in good agreement with 24-h ABPM. Further studies are required to confirm the clinical relevance of these findings by comparing the association of NBP in the hospital ward assessed by manual monitoring with preclinical organ damage and cardiovascular and cerebrovascular outcomes.
format Online
Article
Text
id pubmed-3665662
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-36656622013-05-29 Estimate of nocturnal blood pressure and detection of non-dippers based on clinical or ambulatory monitoring in the inpatient setting Xu, Tan Zhang, Yongqing Tan, Xuerui BMC Cardiovasc Disord Research Article BACKGROUND: Ambulatory blood pressure monitoring is regarded as the gold standard for monitoring nocturnal blood pressure (NBP) and is usually performed out of office. Currently, a novel method for monitoring NBP is indispensible in the inpatient setting. The widely used manual BP monitoring procedure has the potential to monitor NBP in the hospital setting. The feasibility and accuracy of manual sphygmomanometer to monitor NBP has not been explored widely. METHODS: A cross-sectional study was conducted at the cardiology department of a university-affiliated hospital to study patients with mild-to-moderate essential hypertension. One hundred and fifty-five patients were recruited to compare BP derived from a manual device and ambulatory BP monitoring (ABPM). The manual BP measurement was performed six times at 22:00, 02:00, 06:00, 10:00, 14:00 and 18:00 h. The measurements at 22:00, 02:00 and 06:00 h were defined as night-time and the others as daytime. ABPM was programmed to measure at 30-min intervals between measurements. RESULTS: All-day, daytime and night-time BP did not differ significantly from 24-h ambulatory systolic BP [all-day mean difference −0.52±4.67 mmHg, 95% confidence interval (CI) –1.26 to 0.22, P=0.168; daytime mean difference 0.24±5.45 mmHg, 95% CI −0.62 to 1.11, P=0.580; night-time mean difference 0.30±7.22 mmHg, 95% CI −0.84 to 1.45, P=0.601) rather than diastolic BP. There was a strong correlation between clinical and ambulatory BP for both systolic and diastolic BP. On the basis of ABPM, 101 (65%) patients were classified as non-dippers, compared with 106 (68%) by manual sphygmomanometer (P<0.001). CONCLUSIONS: Traditional manual sphygmomanometer provides similar daytime and night-time systolic BP measurements in hospital. Moreover, the detection of non-dippers by manual methods is in good agreement with 24-h ABPM. Further studies are required to confirm the clinical relevance of these findings by comparing the association of NBP in the hospital ward assessed by manual monitoring with preclinical organ damage and cardiovascular and cerebrovascular outcomes. BioMed Central 2013-05-21 /pmc/articles/PMC3665662/ /pubmed/23692688 http://dx.doi.org/10.1186/1471-2261-13-37 Text en Copyright © 2013 Xu et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Xu, Tan
Zhang, Yongqing
Tan, Xuerui
Estimate of nocturnal blood pressure and detection of non-dippers based on clinical or ambulatory monitoring in the inpatient setting
title Estimate of nocturnal blood pressure and detection of non-dippers based on clinical or ambulatory monitoring in the inpatient setting
title_full Estimate of nocturnal blood pressure and detection of non-dippers based on clinical or ambulatory monitoring in the inpatient setting
title_fullStr Estimate of nocturnal blood pressure and detection of non-dippers based on clinical or ambulatory monitoring in the inpatient setting
title_full_unstemmed Estimate of nocturnal blood pressure and detection of non-dippers based on clinical or ambulatory monitoring in the inpatient setting
title_short Estimate of nocturnal blood pressure and detection of non-dippers based on clinical or ambulatory monitoring in the inpatient setting
title_sort estimate of nocturnal blood pressure and detection of non-dippers based on clinical or ambulatory monitoring in the inpatient setting
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3665662/
https://www.ncbi.nlm.nih.gov/pubmed/23692688
http://dx.doi.org/10.1186/1471-2261-13-37
work_keys_str_mv AT xutan estimateofnocturnalbloodpressureanddetectionofnondippersbasedonclinicalorambulatorymonitoringintheinpatientsetting
AT zhangyongqing estimateofnocturnalbloodpressureanddetectionofnondippersbasedonclinicalorambulatorymonitoringintheinpatientsetting
AT tanxuerui estimateofnocturnalbloodpressureanddetectionofnondippersbasedonclinicalorambulatorymonitoringintheinpatientsetting