Cargando…

Marginal Microleakage and Morphological Characteristics of a Solvent-Free One-Step Self-Etch Adhesive (B1SF)

OBJECTIVE: In recent years, newly developed solvent-free dental adhesives have been introduced. The aim of this study was to evaluate the marginal integrity of a new one-step solvent-free self-etch adhesive and to compare it with a commonly used two-step self-etch adhesive as the gold standard. MATE...

Descripción completa

Detalles Bibliográficos
Autores principales: Khoroushi, Maryam, Shirban, Farinaz, Shirban, Mohammadreza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tehran University of Medical Sciences 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3666063/
https://www.ncbi.nlm.nih.gov/pubmed/23724201
_version_ 1782271342660288512
author Khoroushi, Maryam
Shirban, Farinaz
Shirban, Mohammadreza
author_facet Khoroushi, Maryam
Shirban, Farinaz
Shirban, Mohammadreza
author_sort Khoroushi, Maryam
collection PubMed
description OBJECTIVE: In recent years, newly developed solvent-free dental adhesives have been introduced. The aim of this study was to evaluate the marginal integrity of a new one-step solvent-free self-etch adhesive and to compare it with a commonly used two-step self-etch adhesive as the gold standard. MATERIALS AND METHODS: Class V cavities (2×4×1.5 mm) were prepared on the buccal aspects of 28 human premolars. The cervical margins of the cavity preparations were placed 1 mm apical to the CEJ. Clearfil SE Bond (CSEB) (two-step self-etch adhesive) and Bond 1SF (B1SF) (one-step self-etch adhesive) were applied to the cavities in groups 1 and 2 (n=14), respectively. Then, the specimens were restored with A2 shade of APX composite resin. Each group was evaluated for dye penetration under a stereomicroscope at ×32 after 24 hours and 500 rounds of thermocycling. Statistical analyses were carried out using Mann Whitney test (α=0.05). In addition, in each experimental group, two specimens were prepared for analysis under SEM. RESULTS: There were no significant differences in enamel margin microleakage between the two adhesives used (P=0.24(; whereas, there were significant differences in dentin margin microleakage between CSEB and B1SF (P=0.004). Dentin microleakage of B1SF was higher than that of CSEB. CONCLUSION: Results showed that the enamel marginal integrity of B1SF as a newly developed one-step solvent-free self-etch adhesive was similar to that of CSEB as a commonly used two-step self-etch; however, dentinal sealing of CSEB was better than that of B1SF.
format Online
Article
Text
id pubmed-3666063
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Tehran University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-36660632013-05-30 Marginal Microleakage and Morphological Characteristics of a Solvent-Free One-Step Self-Etch Adhesive (B1SF) Khoroushi, Maryam Shirban, Farinaz Shirban, Mohammadreza J Dent (Tehran) Original Article OBJECTIVE: In recent years, newly developed solvent-free dental adhesives have been introduced. The aim of this study was to evaluate the marginal integrity of a new one-step solvent-free self-etch adhesive and to compare it with a commonly used two-step self-etch adhesive as the gold standard. MATERIALS AND METHODS: Class V cavities (2×4×1.5 mm) were prepared on the buccal aspects of 28 human premolars. The cervical margins of the cavity preparations were placed 1 mm apical to the CEJ. Clearfil SE Bond (CSEB) (two-step self-etch adhesive) and Bond 1SF (B1SF) (one-step self-etch adhesive) were applied to the cavities in groups 1 and 2 (n=14), respectively. Then, the specimens were restored with A2 shade of APX composite resin. Each group was evaluated for dye penetration under a stereomicroscope at ×32 after 24 hours and 500 rounds of thermocycling. Statistical analyses were carried out using Mann Whitney test (α=0.05). In addition, in each experimental group, two specimens were prepared for analysis under SEM. RESULTS: There were no significant differences in enamel margin microleakage between the two adhesives used (P=0.24(; whereas, there were significant differences in dentin margin microleakage between CSEB and B1SF (P=0.004). Dentin microleakage of B1SF was higher than that of CSEB. CONCLUSION: Results showed that the enamel marginal integrity of B1SF as a newly developed one-step solvent-free self-etch adhesive was similar to that of CSEB as a commonly used two-step self-etch; however, dentinal sealing of CSEB was better than that of B1SF. Tehran University of Medical Sciences 2013-01-31 2013-01 /pmc/articles/PMC3666063/ /pubmed/23724201 Text en Copyright © Dental Research Center, Tehran University of Medical Sciences http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0), which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.
spellingShingle Original Article
Khoroushi, Maryam
Shirban, Farinaz
Shirban, Mohammadreza
Marginal Microleakage and Morphological Characteristics of a Solvent-Free One-Step Self-Etch Adhesive (B1SF)
title Marginal Microleakage and Morphological Characteristics of a Solvent-Free One-Step Self-Etch Adhesive (B1SF)
title_full Marginal Microleakage and Morphological Characteristics of a Solvent-Free One-Step Self-Etch Adhesive (B1SF)
title_fullStr Marginal Microleakage and Morphological Characteristics of a Solvent-Free One-Step Self-Etch Adhesive (B1SF)
title_full_unstemmed Marginal Microleakage and Morphological Characteristics of a Solvent-Free One-Step Self-Etch Adhesive (B1SF)
title_short Marginal Microleakage and Morphological Characteristics of a Solvent-Free One-Step Self-Etch Adhesive (B1SF)
title_sort marginal microleakage and morphological characteristics of a solvent-free one-step self-etch adhesive (b1sf)
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3666063/
https://www.ncbi.nlm.nih.gov/pubmed/23724201
work_keys_str_mv AT khoroushimaryam marginalmicroleakageandmorphologicalcharacteristicsofasolventfreeonestepselfetchadhesiveb1sf
AT shirbanfarinaz marginalmicroleakageandmorphologicalcharacteristicsofasolventfreeonestepselfetchadhesiveb1sf
AT shirbanmohammadreza marginalmicroleakageandmorphologicalcharacteristicsofasolventfreeonestepselfetchadhesiveb1sf