Cargando…

The Effect of Aging on the Accuracy of New Friction-Style Mechanical Torque Limiting Devices for Dental Implants

OBJECTIVE: High variability in delivering the target torque is reported for friction-style mechanical torque limiting devices (F-S MTLDs). The effect of aging (number of use) on the accuracy of these devices is not clear. The purpose of this study was to assess the effect of aging on the accuracy (±...

Descripción completa

Detalles Bibliográficos
Autores principales: Saboury, Aboulfazl, Sadr, Seyed Jalil, Fayaz, Ali, Mahshid, Minoo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tehran University of Medical Sciences 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3666064/
https://www.ncbi.nlm.nih.gov/pubmed/23724202
_version_ 1782271342901460992
author Saboury, Aboulfazl
Sadr, Seyed Jalil
Fayaz, Ali
Mahshid, Minoo
author_facet Saboury, Aboulfazl
Sadr, Seyed Jalil
Fayaz, Ali
Mahshid, Minoo
author_sort Saboury, Aboulfazl
collection PubMed
description OBJECTIVE: High variability in delivering the target torque is reported for friction-style mechanical torque limiting devices (F-S MTLDs). The effect of aging (number of use) on the accuracy of these devices is not clear. The purpose of this study was to assess the effect of aging on the accuracy (±10% of the target torque) of F-S MTLDs. MATERIALS AND METHODS: Fifteen new F-S MTLDs and their appropriate drivers from three different implant manufacturers (Astra Tech, Biohorizon and Dr Idhe), five for each type, were selected. The procedure of peak torque measurement was performed in ten sequences before and after aging. In each sequence, ten repetitions of peak torque values were registered for the aging procedure. To measure the output of each device, a Tohnichi torque gauge was used. RESULTS: Before aging, peak torque measurements of all the devices tested in this study falled within 10% of their preset target values. After aging, a significant difference was seen between raw error values of three groups of MTLDs (P<0.05). More than 50% of all peak torque measurements demonstrated more than 10% difference from their torque values after aging. CONCLUSION: Within the limitation of this study, aging as an independent factor affects the accuracy of F-S MTLDs. Astra Tech MTLDs presented the most consistent torque output for 25 Ncm target torque.
format Online
Article
Text
id pubmed-3666064
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Tehran University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-36660642013-05-30 The Effect of Aging on the Accuracy of New Friction-Style Mechanical Torque Limiting Devices for Dental Implants Saboury, Aboulfazl Sadr, Seyed Jalil Fayaz, Ali Mahshid, Minoo J Dent (Tehran) Original Article OBJECTIVE: High variability in delivering the target torque is reported for friction-style mechanical torque limiting devices (F-S MTLDs). The effect of aging (number of use) on the accuracy of these devices is not clear. The purpose of this study was to assess the effect of aging on the accuracy (±10% of the target torque) of F-S MTLDs. MATERIALS AND METHODS: Fifteen new F-S MTLDs and their appropriate drivers from three different implant manufacturers (Astra Tech, Biohorizon and Dr Idhe), five for each type, were selected. The procedure of peak torque measurement was performed in ten sequences before and after aging. In each sequence, ten repetitions of peak torque values were registered for the aging procedure. To measure the output of each device, a Tohnichi torque gauge was used. RESULTS: Before aging, peak torque measurements of all the devices tested in this study falled within 10% of their preset target values. After aging, a significant difference was seen between raw error values of three groups of MTLDs (P<0.05). More than 50% of all peak torque measurements demonstrated more than 10% difference from their torque values after aging. CONCLUSION: Within the limitation of this study, aging as an independent factor affects the accuracy of F-S MTLDs. Astra Tech MTLDs presented the most consistent torque output for 25 Ncm target torque. Tehran University of Medical Sciences 2013-01-31 2013-01 /pmc/articles/PMC3666064/ /pubmed/23724202 Text en Copyright © Dental Research Center, Tehran University of Medical Sciences http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0), which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.
spellingShingle Original Article
Saboury, Aboulfazl
Sadr, Seyed Jalil
Fayaz, Ali
Mahshid, Minoo
The Effect of Aging on the Accuracy of New Friction-Style Mechanical Torque Limiting Devices for Dental Implants
title The Effect of Aging on the Accuracy of New Friction-Style Mechanical Torque Limiting Devices for Dental Implants
title_full The Effect of Aging on the Accuracy of New Friction-Style Mechanical Torque Limiting Devices for Dental Implants
title_fullStr The Effect of Aging on the Accuracy of New Friction-Style Mechanical Torque Limiting Devices for Dental Implants
title_full_unstemmed The Effect of Aging on the Accuracy of New Friction-Style Mechanical Torque Limiting Devices for Dental Implants
title_short The Effect of Aging on the Accuracy of New Friction-Style Mechanical Torque Limiting Devices for Dental Implants
title_sort effect of aging on the accuracy of new friction-style mechanical torque limiting devices for dental implants
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3666064/
https://www.ncbi.nlm.nih.gov/pubmed/23724202
work_keys_str_mv AT sabouryaboulfazl theeffectofagingontheaccuracyofnewfrictionstylemechanicaltorquelimitingdevicesfordentalimplants
AT sadrseyedjalil theeffectofagingontheaccuracyofnewfrictionstylemechanicaltorquelimitingdevicesfordentalimplants
AT fayazali theeffectofagingontheaccuracyofnewfrictionstylemechanicaltorquelimitingdevicesfordentalimplants
AT mahshidminoo theeffectofagingontheaccuracyofnewfrictionstylemechanicaltorquelimitingdevicesfordentalimplants
AT sabouryaboulfazl effectofagingontheaccuracyofnewfrictionstylemechanicaltorquelimitingdevicesfordentalimplants
AT sadrseyedjalil effectofagingontheaccuracyofnewfrictionstylemechanicaltorquelimitingdevicesfordentalimplants
AT fayazali effectofagingontheaccuracyofnewfrictionstylemechanicaltorquelimitingdevicesfordentalimplants
AT mahshidminoo effectofagingontheaccuracyofnewfrictionstylemechanicaltorquelimitingdevicesfordentalimplants