Cargando…

The durability of examination gloves used on intensive care units

BACKGROUND: The use of examination gloves is part of the standard precautions to prevent medical staff from transmission of infectious agents between patients. Gloves also protect the staff from infectious agents originating from patients. Adequate protection, however, depends on intact gloves. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Hübner, Nils-Olaf, Goerdt, Anna-Maria, Mannerow, Axel, Pohrt, Ute, Heidecke, Claus-Dieter, Kramer, Axel, Partecke, Lars Ivo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3666964/
https://www.ncbi.nlm.nih.gov/pubmed/23687937
http://dx.doi.org/10.1186/1471-2334-13-226
_version_ 1782271413375205376
author Hübner, Nils-Olaf
Goerdt, Anna-Maria
Mannerow, Axel
Pohrt, Ute
Heidecke, Claus-Dieter
Kramer, Axel
Partecke, Lars Ivo
author_facet Hübner, Nils-Olaf
Goerdt, Anna-Maria
Mannerow, Axel
Pohrt, Ute
Heidecke, Claus-Dieter
Kramer, Axel
Partecke, Lars Ivo
author_sort Hübner, Nils-Olaf
collection PubMed
description BACKGROUND: The use of examination gloves is part of the standard precautions to prevent medical staff from transmission of infectious agents between patients. Gloves also protect the staff from infectious agents originating from patients. Adequate protection, however, depends on intact gloves. The risk of perforation of examination gloves is thought to correlate with duration of wearing, yet, only very few prospective studies have been performed on this issue. METHODS: A total number of 1500 consecutively used pairs of examination gloves of two different brands and materials (latex and nitrile) were collected over a period of two months on two ICU’s. Used gloves were examined for micro perforations using the “water-proof-test” according to EN 455–1. Cox-regression for both glove types was used to estimate optimal changing intervals. RESULTS: Only 26% of gloves were worn longer than 15 min. The total perforation rate was 10.3% with significant differences and deterioration of integrity of gloves between brands (p<0.001). Apart from the brand, “change of wound dressing” (p = 0.049) and “washing patients” (p = 0.001) were also significantly associated with an increased risk of perforation. CONCLUSION: Medical gloves show marked differences in their durability that cannot be predicted based on the technical data routinely provided by the manufacturer. Based on the increase of micro perforations over time and the wearing behavior, recommendations for maximum wearing time of gloves should be given. Changing of gloves after 15 min could be a good compromise between feasibility and safety. HCWs should be aware of the benefits and limitations of medical gloves. To improve personal hygiene hand disinfection should be further encouraged.
format Online
Article
Text
id pubmed-3666964
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-36669642013-05-30 The durability of examination gloves used on intensive care units Hübner, Nils-Olaf Goerdt, Anna-Maria Mannerow, Axel Pohrt, Ute Heidecke, Claus-Dieter Kramer, Axel Partecke, Lars Ivo BMC Infect Dis Research Article BACKGROUND: The use of examination gloves is part of the standard precautions to prevent medical staff from transmission of infectious agents between patients. Gloves also protect the staff from infectious agents originating from patients. Adequate protection, however, depends on intact gloves. The risk of perforation of examination gloves is thought to correlate with duration of wearing, yet, only very few prospective studies have been performed on this issue. METHODS: A total number of 1500 consecutively used pairs of examination gloves of two different brands and materials (latex and nitrile) were collected over a period of two months on two ICU’s. Used gloves were examined for micro perforations using the “water-proof-test” according to EN 455–1. Cox-regression for both glove types was used to estimate optimal changing intervals. RESULTS: Only 26% of gloves were worn longer than 15 min. The total perforation rate was 10.3% with significant differences and deterioration of integrity of gloves between brands (p<0.001). Apart from the brand, “change of wound dressing” (p = 0.049) and “washing patients” (p = 0.001) were also significantly associated with an increased risk of perforation. CONCLUSION: Medical gloves show marked differences in their durability that cannot be predicted based on the technical data routinely provided by the manufacturer. Based on the increase of micro perforations over time and the wearing behavior, recommendations for maximum wearing time of gloves should be given. Changing of gloves after 15 min could be a good compromise between feasibility and safety. HCWs should be aware of the benefits and limitations of medical gloves. To improve personal hygiene hand disinfection should be further encouraged. BioMed Central 2013-05-20 /pmc/articles/PMC3666964/ /pubmed/23687937 http://dx.doi.org/10.1186/1471-2334-13-226 Text en Copyright © 2013 Hübner et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Hübner, Nils-Olaf
Goerdt, Anna-Maria
Mannerow, Axel
Pohrt, Ute
Heidecke, Claus-Dieter
Kramer, Axel
Partecke, Lars Ivo
The durability of examination gloves used on intensive care units
title The durability of examination gloves used on intensive care units
title_full The durability of examination gloves used on intensive care units
title_fullStr The durability of examination gloves used on intensive care units
title_full_unstemmed The durability of examination gloves used on intensive care units
title_short The durability of examination gloves used on intensive care units
title_sort durability of examination gloves used on intensive care units
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3666964/
https://www.ncbi.nlm.nih.gov/pubmed/23687937
http://dx.doi.org/10.1186/1471-2334-13-226
work_keys_str_mv AT hubnernilsolaf thedurabilityofexaminationglovesusedonintensivecareunits
AT goerdtannamaria thedurabilityofexaminationglovesusedonintensivecareunits
AT mannerowaxel thedurabilityofexaminationglovesusedonintensivecareunits
AT pohrtute thedurabilityofexaminationglovesusedonintensivecareunits
AT heideckeclausdieter thedurabilityofexaminationglovesusedonintensivecareunits
AT krameraxel thedurabilityofexaminationglovesusedonintensivecareunits
AT parteckelarsivo thedurabilityofexaminationglovesusedonintensivecareunits
AT hubnernilsolaf durabilityofexaminationglovesusedonintensivecareunits
AT goerdtannamaria durabilityofexaminationglovesusedonintensivecareunits
AT mannerowaxel durabilityofexaminationglovesusedonintensivecareunits
AT pohrtute durabilityofexaminationglovesusedonintensivecareunits
AT heideckeclausdieter durabilityofexaminationglovesusedonintensivecareunits
AT krameraxel durabilityofexaminationglovesusedonintensivecareunits
AT parteckelarsivo durabilityofexaminationglovesusedonintensivecareunits