Cargando…
The durability of examination gloves used on intensive care units
BACKGROUND: The use of examination gloves is part of the standard precautions to prevent medical staff from transmission of infectious agents between patients. Gloves also protect the staff from infectious agents originating from patients. Adequate protection, however, depends on intact gloves. The...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3666964/ https://www.ncbi.nlm.nih.gov/pubmed/23687937 http://dx.doi.org/10.1186/1471-2334-13-226 |
_version_ | 1782271413375205376 |
---|---|
author | Hübner, Nils-Olaf Goerdt, Anna-Maria Mannerow, Axel Pohrt, Ute Heidecke, Claus-Dieter Kramer, Axel Partecke, Lars Ivo |
author_facet | Hübner, Nils-Olaf Goerdt, Anna-Maria Mannerow, Axel Pohrt, Ute Heidecke, Claus-Dieter Kramer, Axel Partecke, Lars Ivo |
author_sort | Hübner, Nils-Olaf |
collection | PubMed |
description | BACKGROUND: The use of examination gloves is part of the standard precautions to prevent medical staff from transmission of infectious agents between patients. Gloves also protect the staff from infectious agents originating from patients. Adequate protection, however, depends on intact gloves. The risk of perforation of examination gloves is thought to correlate with duration of wearing, yet, only very few prospective studies have been performed on this issue. METHODS: A total number of 1500 consecutively used pairs of examination gloves of two different brands and materials (latex and nitrile) were collected over a period of two months on two ICU’s. Used gloves were examined for micro perforations using the “water-proof-test” according to EN 455–1. Cox-regression for both glove types was used to estimate optimal changing intervals. RESULTS: Only 26% of gloves were worn longer than 15 min. The total perforation rate was 10.3% with significant differences and deterioration of integrity of gloves between brands (p<0.001). Apart from the brand, “change of wound dressing” (p = 0.049) and “washing patients” (p = 0.001) were also significantly associated with an increased risk of perforation. CONCLUSION: Medical gloves show marked differences in their durability that cannot be predicted based on the technical data routinely provided by the manufacturer. Based on the increase of micro perforations over time and the wearing behavior, recommendations for maximum wearing time of gloves should be given. Changing of gloves after 15 min could be a good compromise between feasibility and safety. HCWs should be aware of the benefits and limitations of medical gloves. To improve personal hygiene hand disinfection should be further encouraged. |
format | Online Article Text |
id | pubmed-3666964 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-36669642013-05-30 The durability of examination gloves used on intensive care units Hübner, Nils-Olaf Goerdt, Anna-Maria Mannerow, Axel Pohrt, Ute Heidecke, Claus-Dieter Kramer, Axel Partecke, Lars Ivo BMC Infect Dis Research Article BACKGROUND: The use of examination gloves is part of the standard precautions to prevent medical staff from transmission of infectious agents between patients. Gloves also protect the staff from infectious agents originating from patients. Adequate protection, however, depends on intact gloves. The risk of perforation of examination gloves is thought to correlate with duration of wearing, yet, only very few prospective studies have been performed on this issue. METHODS: A total number of 1500 consecutively used pairs of examination gloves of two different brands and materials (latex and nitrile) were collected over a period of two months on two ICU’s. Used gloves were examined for micro perforations using the “water-proof-test” according to EN 455–1. Cox-regression for both glove types was used to estimate optimal changing intervals. RESULTS: Only 26% of gloves were worn longer than 15 min. The total perforation rate was 10.3% with significant differences and deterioration of integrity of gloves between brands (p<0.001). Apart from the brand, “change of wound dressing” (p = 0.049) and “washing patients” (p = 0.001) were also significantly associated with an increased risk of perforation. CONCLUSION: Medical gloves show marked differences in their durability that cannot be predicted based on the technical data routinely provided by the manufacturer. Based on the increase of micro perforations over time and the wearing behavior, recommendations for maximum wearing time of gloves should be given. Changing of gloves after 15 min could be a good compromise between feasibility and safety. HCWs should be aware of the benefits and limitations of medical gloves. To improve personal hygiene hand disinfection should be further encouraged. BioMed Central 2013-05-20 /pmc/articles/PMC3666964/ /pubmed/23687937 http://dx.doi.org/10.1186/1471-2334-13-226 Text en Copyright © 2013 Hübner et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Hübner, Nils-Olaf Goerdt, Anna-Maria Mannerow, Axel Pohrt, Ute Heidecke, Claus-Dieter Kramer, Axel Partecke, Lars Ivo The durability of examination gloves used on intensive care units |
title | The durability of examination gloves used on intensive care units |
title_full | The durability of examination gloves used on intensive care units |
title_fullStr | The durability of examination gloves used on intensive care units |
title_full_unstemmed | The durability of examination gloves used on intensive care units |
title_short | The durability of examination gloves used on intensive care units |
title_sort | durability of examination gloves used on intensive care units |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3666964/ https://www.ncbi.nlm.nih.gov/pubmed/23687937 http://dx.doi.org/10.1186/1471-2334-13-226 |
work_keys_str_mv | AT hubnernilsolaf thedurabilityofexaminationglovesusedonintensivecareunits AT goerdtannamaria thedurabilityofexaminationglovesusedonintensivecareunits AT mannerowaxel thedurabilityofexaminationglovesusedonintensivecareunits AT pohrtute thedurabilityofexaminationglovesusedonintensivecareunits AT heideckeclausdieter thedurabilityofexaminationglovesusedonintensivecareunits AT krameraxel thedurabilityofexaminationglovesusedonintensivecareunits AT parteckelarsivo thedurabilityofexaminationglovesusedonintensivecareunits AT hubnernilsolaf durabilityofexaminationglovesusedonintensivecareunits AT goerdtannamaria durabilityofexaminationglovesusedonintensivecareunits AT mannerowaxel durabilityofexaminationglovesusedonintensivecareunits AT pohrtute durabilityofexaminationglovesusedonintensivecareunits AT heideckeclausdieter durabilityofexaminationglovesusedonintensivecareunits AT krameraxel durabilityofexaminationglovesusedonintensivecareunits AT parteckelarsivo durabilityofexaminationglovesusedonintensivecareunits |