Cargando…

Simultaneous quantification of Bi(III) and U(VI) in environmental water samples with a complicated matrix containing organic compounds

Trace amounts of bismuth(III) and uranium(VI) can be simultaneously determined in a single scan by adsorptive cathodic stripping voltammetry in the presence of cupferron as a complexing agent. Optimal conditions were found to be: 0.1 mol L(−1) acetate buffer (pH 5.3), 5 × 10(−5) mol L(−1) cupferron,...

Descripción completa

Detalles Bibliográficos
Autores principales: Grabarczyk, Malgorzata, Koper, Anna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3667356/
https://www.ncbi.nlm.nih.gov/pubmed/23108710
http://dx.doi.org/10.1007/s10661-012-2963-8
_version_ 1782271488157548544
author Grabarczyk, Malgorzata
Koper, Anna
author_facet Grabarczyk, Malgorzata
Koper, Anna
author_sort Grabarczyk, Malgorzata
collection PubMed
description Trace amounts of bismuth(III) and uranium(VI) can be simultaneously determined in a single scan by adsorptive cathodic stripping voltammetry in the presence of cupferron as a complexing agent. Optimal conditions were found to be: 0.1 mol L(−1) acetate buffer (pH 5.3), 5 × 10(−5) mol L(−1) cupferron, accumulation potential of −0.25 V, and accumulation time of 30 s. The linear range of Bi(III) and U(VI) was observed over the concentration range from 2 × 10(−9) to 2 × 10(−7) mol L(−1) and from 1 × 10(−8) to 5 × 10(−7) mol L(−1), respectively. The influence of the main components of real water samples such as foreign ions and organic substances (surface active substances, humic substances) was precisely investigated. The method was applied to the simultaneous measurements of bismuth and uranium in natural water samples.
format Online
Article
Text
id pubmed-3667356
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-36673562013-06-03 Simultaneous quantification of Bi(III) and U(VI) in environmental water samples with a complicated matrix containing organic compounds Grabarczyk, Malgorzata Koper, Anna Environ Monit Assess Article Trace amounts of bismuth(III) and uranium(VI) can be simultaneously determined in a single scan by adsorptive cathodic stripping voltammetry in the presence of cupferron as a complexing agent. Optimal conditions were found to be: 0.1 mol L(−1) acetate buffer (pH 5.3), 5 × 10(−5) mol L(−1) cupferron, accumulation potential of −0.25 V, and accumulation time of 30 s. The linear range of Bi(III) and U(VI) was observed over the concentration range from 2 × 10(−9) to 2 × 10(−7) mol L(−1) and from 1 × 10(−8) to 5 × 10(−7) mol L(−1), respectively. The influence of the main components of real water samples such as foreign ions and organic substances (surface active substances, humic substances) was precisely investigated. The method was applied to the simultaneous measurements of bismuth and uranium in natural water samples. Springer Netherlands 2012-10-30 2013 /pmc/articles/PMC3667356/ /pubmed/23108710 http://dx.doi.org/10.1007/s10661-012-2963-8 Text en © The Author(s) 2012 https://creativecommons.org/licenses/by/4.0/ This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Article
Grabarczyk, Malgorzata
Koper, Anna
Simultaneous quantification of Bi(III) and U(VI) in environmental water samples with a complicated matrix containing organic compounds
title Simultaneous quantification of Bi(III) and U(VI) in environmental water samples with a complicated matrix containing organic compounds
title_full Simultaneous quantification of Bi(III) and U(VI) in environmental water samples with a complicated matrix containing organic compounds
title_fullStr Simultaneous quantification of Bi(III) and U(VI) in environmental water samples with a complicated matrix containing organic compounds
title_full_unstemmed Simultaneous quantification of Bi(III) and U(VI) in environmental water samples with a complicated matrix containing organic compounds
title_short Simultaneous quantification of Bi(III) and U(VI) in environmental water samples with a complicated matrix containing organic compounds
title_sort simultaneous quantification of bi(iii) and u(vi) in environmental water samples with a complicated matrix containing organic compounds
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3667356/
https://www.ncbi.nlm.nih.gov/pubmed/23108710
http://dx.doi.org/10.1007/s10661-012-2963-8
work_keys_str_mv AT grabarczykmalgorzata simultaneousquantificationofbiiiianduviinenvironmentalwatersampleswithacomplicatedmatrixcontainingorganiccompounds
AT koperanna simultaneousquantificationofbiiiianduviinenvironmentalwatersampleswithacomplicatedmatrixcontainingorganiccompounds