Cargando…

SHILO, a novel dual imaging approach for simultaneous HI-/LOw temporal (Low-/Hi-spatial) resolution imaging for vascular dynamic contrast enhanced cardiovascular magnetic resonance: numerical simulations and feasibility in the carotid arteries

BACKGROUND: Dynamic contrast enhanced (DCE) cardiovascular magnetic resonance (CMR) is increasingly used to quantify microvessels and permeability in atherosclerosis. Accurate quantification depends on reliable sampling of both vessel wall (VW) uptake and contrast agent dynamic in the blood plasma (...

Descripción completa

Detalles Bibliográficos
Autores principales: Calcagno, Claudia, Robson, Philip M, Ramachandran, Sarayu, Mani, Venkatesh, Kotys-Traughber, Melanie, Cham, Matthew, Fischer, Stefan E, Fayad, Zahi A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3668185/
https://www.ncbi.nlm.nih.gov/pubmed/23706156
http://dx.doi.org/10.1186/1532-429X-15-42
_version_ 1782271586163752960
author Calcagno, Claudia
Robson, Philip M
Ramachandran, Sarayu
Mani, Venkatesh
Kotys-Traughber, Melanie
Cham, Matthew
Fischer, Stefan E
Fayad, Zahi A
author_facet Calcagno, Claudia
Robson, Philip M
Ramachandran, Sarayu
Mani, Venkatesh
Kotys-Traughber, Melanie
Cham, Matthew
Fischer, Stefan E
Fayad, Zahi A
author_sort Calcagno, Claudia
collection PubMed
description BACKGROUND: Dynamic contrast enhanced (DCE) cardiovascular magnetic resonance (CMR) is increasingly used to quantify microvessels and permeability in atherosclerosis. Accurate quantification depends on reliable sampling of both vessel wall (VW) uptake and contrast agent dynamic in the blood plasma (the so called arterial input function, AIF). This poses specific challenges in terms of spatial/temporal resolution and matched dynamic MR signal range, which are suboptimal in current vascular DCE-CMR protocols. In this study we describe a novel dual-imaging approach, which allows acquiring simultaneously AIF and VW images using different spatial/temporal resolution and optimizes imaging parameters for the two compartments. We refer to this new acquisition as SHILO, Simultaneous HI-/LOw-temporal (low-/hi-spatial) resolution DCE-imaging. METHODS: In SHILO, the acquisition of low spatial resolution single-shot AIF images is interleaved with segments of higher spatial resolution images of the VW. This allows sampling the AIF and VW with different spatial/temporal resolution and acquisition parameters, at independent spatial locations. We show the adequacy of this temporal sampling scheme by using numerical simulations. Following, we validate the MR signal of SHILO against a standard 2D spoiled gradient recalled echo (SPGR) acquisition with in vitro and in vivo experiments. Finally, we show feasibility of using SHILO imaging in subjects with carotid atherosclerosis. RESULTS: Our simulations confirmed the superiority of the SHILO temporal sampling scheme over conventional strategies that sample AIF and tissue curves at the same time resolution. Both the median relative errors and standard deviation of absolute parameter values were lower for the SHILO than for conventional sampling schemes. We showed equivalency of the SHILO signal and conventional 2D SPGR imaging, using both in vitro phantom experiments (R(2) =0.99) and in vivo acquisitions (R(2) =0.95). Finally, we showed feasibility of using the newly developed SHILO sequence to acquire DCE-CMR data in subjects with carotid atherosclerosis to calculate plaque perfusion indices. CONCLUSIONS: We successfully demonstrate the feasibility of using the newly developed SHILO dual-imaging technique for simultaneous AIF and VW imaging in DCE-CMR of atherosclerosis. Our initial results are promising and warrant further investigation of this technique in wider studies measuring kinetic parameters of plaque neovascularization with validation against gold standard techniques.
format Online
Article
Text
id pubmed-3668185
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-36681852013-06-03 SHILO, a novel dual imaging approach for simultaneous HI-/LOw temporal (Low-/Hi-spatial) resolution imaging for vascular dynamic contrast enhanced cardiovascular magnetic resonance: numerical simulations and feasibility in the carotid arteries Calcagno, Claudia Robson, Philip M Ramachandran, Sarayu Mani, Venkatesh Kotys-Traughber, Melanie Cham, Matthew Fischer, Stefan E Fayad, Zahi A J Cardiovasc Magn Reson Technical Notes BACKGROUND: Dynamic contrast enhanced (DCE) cardiovascular magnetic resonance (CMR) is increasingly used to quantify microvessels and permeability in atherosclerosis. Accurate quantification depends on reliable sampling of both vessel wall (VW) uptake and contrast agent dynamic in the blood plasma (the so called arterial input function, AIF). This poses specific challenges in terms of spatial/temporal resolution and matched dynamic MR signal range, which are suboptimal in current vascular DCE-CMR protocols. In this study we describe a novel dual-imaging approach, which allows acquiring simultaneously AIF and VW images using different spatial/temporal resolution and optimizes imaging parameters for the two compartments. We refer to this new acquisition as SHILO, Simultaneous HI-/LOw-temporal (low-/hi-spatial) resolution DCE-imaging. METHODS: In SHILO, the acquisition of low spatial resolution single-shot AIF images is interleaved with segments of higher spatial resolution images of the VW. This allows sampling the AIF and VW with different spatial/temporal resolution and acquisition parameters, at independent spatial locations. We show the adequacy of this temporal sampling scheme by using numerical simulations. Following, we validate the MR signal of SHILO against a standard 2D spoiled gradient recalled echo (SPGR) acquisition with in vitro and in vivo experiments. Finally, we show feasibility of using SHILO imaging in subjects with carotid atherosclerosis. RESULTS: Our simulations confirmed the superiority of the SHILO temporal sampling scheme over conventional strategies that sample AIF and tissue curves at the same time resolution. Both the median relative errors and standard deviation of absolute parameter values were lower for the SHILO than for conventional sampling schemes. We showed equivalency of the SHILO signal and conventional 2D SPGR imaging, using both in vitro phantom experiments (R(2) =0.99) and in vivo acquisitions (R(2) =0.95). Finally, we showed feasibility of using the newly developed SHILO sequence to acquire DCE-CMR data in subjects with carotid atherosclerosis to calculate plaque perfusion indices. CONCLUSIONS: We successfully demonstrate the feasibility of using the newly developed SHILO dual-imaging technique for simultaneous AIF and VW imaging in DCE-CMR of atherosclerosis. Our initial results are promising and warrant further investigation of this technique in wider studies measuring kinetic parameters of plaque neovascularization with validation against gold standard techniques. BioMed Central 2013-05-24 /pmc/articles/PMC3668185/ /pubmed/23706156 http://dx.doi.org/10.1186/1532-429X-15-42 Text en Copyright © 2013 Calcagno et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Notes
Calcagno, Claudia
Robson, Philip M
Ramachandran, Sarayu
Mani, Venkatesh
Kotys-Traughber, Melanie
Cham, Matthew
Fischer, Stefan E
Fayad, Zahi A
SHILO, a novel dual imaging approach for simultaneous HI-/LOw temporal (Low-/Hi-spatial) resolution imaging for vascular dynamic contrast enhanced cardiovascular magnetic resonance: numerical simulations and feasibility in the carotid arteries
title SHILO, a novel dual imaging approach for simultaneous HI-/LOw temporal (Low-/Hi-spatial) resolution imaging for vascular dynamic contrast enhanced cardiovascular magnetic resonance: numerical simulations and feasibility in the carotid arteries
title_full SHILO, a novel dual imaging approach for simultaneous HI-/LOw temporal (Low-/Hi-spatial) resolution imaging for vascular dynamic contrast enhanced cardiovascular magnetic resonance: numerical simulations and feasibility in the carotid arteries
title_fullStr SHILO, a novel dual imaging approach for simultaneous HI-/LOw temporal (Low-/Hi-spatial) resolution imaging for vascular dynamic contrast enhanced cardiovascular magnetic resonance: numerical simulations and feasibility in the carotid arteries
title_full_unstemmed SHILO, a novel dual imaging approach for simultaneous HI-/LOw temporal (Low-/Hi-spatial) resolution imaging for vascular dynamic contrast enhanced cardiovascular magnetic resonance: numerical simulations and feasibility in the carotid arteries
title_short SHILO, a novel dual imaging approach for simultaneous HI-/LOw temporal (Low-/Hi-spatial) resolution imaging for vascular dynamic contrast enhanced cardiovascular magnetic resonance: numerical simulations and feasibility in the carotid arteries
title_sort shilo, a novel dual imaging approach for simultaneous hi-/low temporal (low-/hi-spatial) resolution imaging for vascular dynamic contrast enhanced cardiovascular magnetic resonance: numerical simulations and feasibility in the carotid arteries
topic Technical Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3668185/
https://www.ncbi.nlm.nih.gov/pubmed/23706156
http://dx.doi.org/10.1186/1532-429X-15-42
work_keys_str_mv AT calcagnoclaudia shiloanoveldualimagingapproachforsimultaneoushilowtemporallowhispatialresolutionimagingforvasculardynamiccontrastenhancedcardiovascularmagneticresonancenumericalsimulationsandfeasibilityinthecarotidarteries
AT robsonphilipm shiloanoveldualimagingapproachforsimultaneoushilowtemporallowhispatialresolutionimagingforvasculardynamiccontrastenhancedcardiovascularmagneticresonancenumericalsimulationsandfeasibilityinthecarotidarteries
AT ramachandransarayu shiloanoveldualimagingapproachforsimultaneoushilowtemporallowhispatialresolutionimagingforvasculardynamiccontrastenhancedcardiovascularmagneticresonancenumericalsimulationsandfeasibilityinthecarotidarteries
AT manivenkatesh shiloanoveldualimagingapproachforsimultaneoushilowtemporallowhispatialresolutionimagingforvasculardynamiccontrastenhancedcardiovascularmagneticresonancenumericalsimulationsandfeasibilityinthecarotidarteries
AT kotystraughbermelanie shiloanoveldualimagingapproachforsimultaneoushilowtemporallowhispatialresolutionimagingforvasculardynamiccontrastenhancedcardiovascularmagneticresonancenumericalsimulationsandfeasibilityinthecarotidarteries
AT chammatthew shiloanoveldualimagingapproachforsimultaneoushilowtemporallowhispatialresolutionimagingforvasculardynamiccontrastenhancedcardiovascularmagneticresonancenumericalsimulationsandfeasibilityinthecarotidarteries
AT fischerstefane shiloanoveldualimagingapproachforsimultaneoushilowtemporallowhispatialresolutionimagingforvasculardynamiccontrastenhancedcardiovascularmagneticresonancenumericalsimulationsandfeasibilityinthecarotidarteries
AT fayadzahia shiloanoveldualimagingapproachforsimultaneoushilowtemporallowhispatialresolutionimagingforvasculardynamiccontrastenhancedcardiovascularmagneticresonancenumericalsimulationsandfeasibilityinthecarotidarteries