Cargando…
Ex-PRESS Implantation Versus Trabeculectomy in Uncontrolled Glaucoma: A Meta-Analysis
OBJECTIVE: To evaluate the efficacy and tolerability of Ex-PRESS implantation (Ex-Press) compared with trabeculectomy (Trab) in the treatment of patients with uncontrolled glaucoma. METHODS: A comprehensive literature meta-analysis was performed according to the Cochrane Collaboration methodology to...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3669314/ https://www.ncbi.nlm.nih.gov/pubmed/23741296 http://dx.doi.org/10.1371/journal.pone.0063591 |
Sumario: | OBJECTIVE: To evaluate the efficacy and tolerability of Ex-PRESS implantation (Ex-Press) compared with trabeculectomy (Trab) in the treatment of patients with uncontrolled glaucoma. METHODS: A comprehensive literature meta-analysis was performed according to the Cochrane Collaboration methodology to identify controlled clinical trials comparing Ex-Press with Trab. Efficacy estimates were measured by weight mean difference (WMD) for the percentage intraocular pressure (IOP) reduction from baseline to end-point, odds ratio (OR) for complete success, and qualified success rates. Tolerability estimates were measured by OR for adverse events. All outcomes were reported with a 95% confidence interval (CI). Data were synthesized by Stata 11.0 SE for Windows. RESULTS: Eight controlled clinical trials meeting the predefined criteria were included in the meta-analysis. A total of 605 eyes from 559 patients with medically uncontrolled glaucoma were included. The weighted mean difference of the percentage IOP reduction from baseline was 2.33 (95% confidence interval: −2.59–7.24) when comparing Ex-Press with Trab. Ex-Press was associated with numerically greater, but nonsignificant, IOP lowering efficacy than Trab. The pooled odds ratio comparing Ex-Press with Trab were 0.93 (0.39, 2.23) for the complete success rate and 1.00 (0.39, 2.56) for the qualified success rate. Ex-Press was associated with a significantly lower frequency of hypotony and hyphema than Trab, with pooled ORs of 0.29 (0.13, 0.65) and 0.36 (0.13, 0.97), respectively. CONCLUSION: Ex-Press was associated with equivalent efficacy to Trab in lowering IOP. Comparable proportions of patients reached the IOP target with Ex-Press and Trab. Ex-Press was better tolerated than Trab. |
---|