Cargando…

Ex-PRESS Implantation Versus Trabeculectomy in Uncontrolled Glaucoma: A Meta-Analysis

OBJECTIVE: To evaluate the efficacy and tolerability of Ex-PRESS implantation (Ex-Press) compared with trabeculectomy (Trab) in the treatment of patients with uncontrolled glaucoma. METHODS: A comprehensive literature meta-analysis was performed according to the Cochrane Collaboration methodology to...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Wei, Zhou, Minwen, Huang, Wenbin, Zhang, Xiulan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3669314/
https://www.ncbi.nlm.nih.gov/pubmed/23741296
http://dx.doi.org/10.1371/journal.pone.0063591
_version_ 1782271730836832256
author Wang, Wei
Zhou, Minwen
Huang, Wenbin
Zhang, Xiulan
author_facet Wang, Wei
Zhou, Minwen
Huang, Wenbin
Zhang, Xiulan
author_sort Wang, Wei
collection PubMed
description OBJECTIVE: To evaluate the efficacy and tolerability of Ex-PRESS implantation (Ex-Press) compared with trabeculectomy (Trab) in the treatment of patients with uncontrolled glaucoma. METHODS: A comprehensive literature meta-analysis was performed according to the Cochrane Collaboration methodology to identify controlled clinical trials comparing Ex-Press with Trab. Efficacy estimates were measured by weight mean difference (WMD) for the percentage intraocular pressure (IOP) reduction from baseline to end-point, odds ratio (OR) for complete success, and qualified success rates. Tolerability estimates were measured by OR for adverse events. All outcomes were reported with a 95% confidence interval (CI). Data were synthesized by Stata 11.0 SE for Windows. RESULTS: Eight controlled clinical trials meeting the predefined criteria were included in the meta-analysis. A total of 605 eyes from 559 patients with medically uncontrolled glaucoma were included. The weighted mean difference of the percentage IOP reduction from baseline was 2.33 (95% confidence interval: −2.59–7.24) when comparing Ex-Press with Trab. Ex-Press was associated with numerically greater, but nonsignificant, IOP lowering efficacy than Trab. The pooled odds ratio comparing Ex-Press with Trab were 0.93 (0.39, 2.23) for the complete success rate and 1.00 (0.39, 2.56) for the qualified success rate. Ex-Press was associated with a significantly lower frequency of hypotony and hyphema than Trab, with pooled ORs of 0.29 (0.13, 0.65) and 0.36 (0.13, 0.97), respectively. CONCLUSION: Ex-Press was associated with equivalent efficacy to Trab in lowering IOP. Comparable proportions of patients reached the IOP target with Ex-Press and Trab. Ex-Press was better tolerated than Trab.
format Online
Article
Text
id pubmed-3669314
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-36693142013-06-05 Ex-PRESS Implantation Versus Trabeculectomy in Uncontrolled Glaucoma: A Meta-Analysis Wang, Wei Zhou, Minwen Huang, Wenbin Zhang, Xiulan PLoS One Research Article OBJECTIVE: To evaluate the efficacy and tolerability of Ex-PRESS implantation (Ex-Press) compared with trabeculectomy (Trab) in the treatment of patients with uncontrolled glaucoma. METHODS: A comprehensive literature meta-analysis was performed according to the Cochrane Collaboration methodology to identify controlled clinical trials comparing Ex-Press with Trab. Efficacy estimates were measured by weight mean difference (WMD) for the percentage intraocular pressure (IOP) reduction from baseline to end-point, odds ratio (OR) for complete success, and qualified success rates. Tolerability estimates were measured by OR for adverse events. All outcomes were reported with a 95% confidence interval (CI). Data were synthesized by Stata 11.0 SE for Windows. RESULTS: Eight controlled clinical trials meeting the predefined criteria were included in the meta-analysis. A total of 605 eyes from 559 patients with medically uncontrolled glaucoma were included. The weighted mean difference of the percentage IOP reduction from baseline was 2.33 (95% confidence interval: −2.59–7.24) when comparing Ex-Press with Trab. Ex-Press was associated with numerically greater, but nonsignificant, IOP lowering efficacy than Trab. The pooled odds ratio comparing Ex-Press with Trab were 0.93 (0.39, 2.23) for the complete success rate and 1.00 (0.39, 2.56) for the qualified success rate. Ex-Press was associated with a significantly lower frequency of hypotony and hyphema than Trab, with pooled ORs of 0.29 (0.13, 0.65) and 0.36 (0.13, 0.97), respectively. CONCLUSION: Ex-Press was associated with equivalent efficacy to Trab in lowering IOP. Comparable proportions of patients reached the IOP target with Ex-Press and Trab. Ex-Press was better tolerated than Trab. Public Library of Science 2013-05-31 /pmc/articles/PMC3669314/ /pubmed/23741296 http://dx.doi.org/10.1371/journal.pone.0063591 Text en © 2013 Wang et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Wang, Wei
Zhou, Minwen
Huang, Wenbin
Zhang, Xiulan
Ex-PRESS Implantation Versus Trabeculectomy in Uncontrolled Glaucoma: A Meta-Analysis
title Ex-PRESS Implantation Versus Trabeculectomy in Uncontrolled Glaucoma: A Meta-Analysis
title_full Ex-PRESS Implantation Versus Trabeculectomy in Uncontrolled Glaucoma: A Meta-Analysis
title_fullStr Ex-PRESS Implantation Versus Trabeculectomy in Uncontrolled Glaucoma: A Meta-Analysis
title_full_unstemmed Ex-PRESS Implantation Versus Trabeculectomy in Uncontrolled Glaucoma: A Meta-Analysis
title_short Ex-PRESS Implantation Versus Trabeculectomy in Uncontrolled Glaucoma: A Meta-Analysis
title_sort ex-press implantation versus trabeculectomy in uncontrolled glaucoma: a meta-analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3669314/
https://www.ncbi.nlm.nih.gov/pubmed/23741296
http://dx.doi.org/10.1371/journal.pone.0063591
work_keys_str_mv AT wangwei expressimplantationversustrabeculectomyinuncontrolledglaucomaametaanalysis
AT zhouminwen expressimplantationversustrabeculectomyinuncontrolledglaucomaametaanalysis
AT huangwenbin expressimplantationversustrabeculectomyinuncontrolledglaucomaametaanalysis
AT zhangxiulan expressimplantationversustrabeculectomyinuncontrolledglaucomaametaanalysis