Cargando…
Ex-PRESS Implantation Versus Trabeculectomy in Uncontrolled Glaucoma: A Meta-Analysis
OBJECTIVE: To evaluate the efficacy and tolerability of Ex-PRESS implantation (Ex-Press) compared with trabeculectomy (Trab) in the treatment of patients with uncontrolled glaucoma. METHODS: A comprehensive literature meta-analysis was performed according to the Cochrane Collaboration methodology to...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3669314/ https://www.ncbi.nlm.nih.gov/pubmed/23741296 http://dx.doi.org/10.1371/journal.pone.0063591 |
_version_ | 1782271730836832256 |
---|---|
author | Wang, Wei Zhou, Minwen Huang, Wenbin Zhang, Xiulan |
author_facet | Wang, Wei Zhou, Minwen Huang, Wenbin Zhang, Xiulan |
author_sort | Wang, Wei |
collection | PubMed |
description | OBJECTIVE: To evaluate the efficacy and tolerability of Ex-PRESS implantation (Ex-Press) compared with trabeculectomy (Trab) in the treatment of patients with uncontrolled glaucoma. METHODS: A comprehensive literature meta-analysis was performed according to the Cochrane Collaboration methodology to identify controlled clinical trials comparing Ex-Press with Trab. Efficacy estimates were measured by weight mean difference (WMD) for the percentage intraocular pressure (IOP) reduction from baseline to end-point, odds ratio (OR) for complete success, and qualified success rates. Tolerability estimates were measured by OR for adverse events. All outcomes were reported with a 95% confidence interval (CI). Data were synthesized by Stata 11.0 SE for Windows. RESULTS: Eight controlled clinical trials meeting the predefined criteria were included in the meta-analysis. A total of 605 eyes from 559 patients with medically uncontrolled glaucoma were included. The weighted mean difference of the percentage IOP reduction from baseline was 2.33 (95% confidence interval: −2.59–7.24) when comparing Ex-Press with Trab. Ex-Press was associated with numerically greater, but nonsignificant, IOP lowering efficacy than Trab. The pooled odds ratio comparing Ex-Press with Trab were 0.93 (0.39, 2.23) for the complete success rate and 1.00 (0.39, 2.56) for the qualified success rate. Ex-Press was associated with a significantly lower frequency of hypotony and hyphema than Trab, with pooled ORs of 0.29 (0.13, 0.65) and 0.36 (0.13, 0.97), respectively. CONCLUSION: Ex-Press was associated with equivalent efficacy to Trab in lowering IOP. Comparable proportions of patients reached the IOP target with Ex-Press and Trab. Ex-Press was better tolerated than Trab. |
format | Online Article Text |
id | pubmed-3669314 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-36693142013-06-05 Ex-PRESS Implantation Versus Trabeculectomy in Uncontrolled Glaucoma: A Meta-Analysis Wang, Wei Zhou, Minwen Huang, Wenbin Zhang, Xiulan PLoS One Research Article OBJECTIVE: To evaluate the efficacy and tolerability of Ex-PRESS implantation (Ex-Press) compared with trabeculectomy (Trab) in the treatment of patients with uncontrolled glaucoma. METHODS: A comprehensive literature meta-analysis was performed according to the Cochrane Collaboration methodology to identify controlled clinical trials comparing Ex-Press with Trab. Efficacy estimates were measured by weight mean difference (WMD) for the percentage intraocular pressure (IOP) reduction from baseline to end-point, odds ratio (OR) for complete success, and qualified success rates. Tolerability estimates were measured by OR for adverse events. All outcomes were reported with a 95% confidence interval (CI). Data were synthesized by Stata 11.0 SE for Windows. RESULTS: Eight controlled clinical trials meeting the predefined criteria were included in the meta-analysis. A total of 605 eyes from 559 patients with medically uncontrolled glaucoma were included. The weighted mean difference of the percentage IOP reduction from baseline was 2.33 (95% confidence interval: −2.59–7.24) when comparing Ex-Press with Trab. Ex-Press was associated with numerically greater, but nonsignificant, IOP lowering efficacy than Trab. The pooled odds ratio comparing Ex-Press with Trab were 0.93 (0.39, 2.23) for the complete success rate and 1.00 (0.39, 2.56) for the qualified success rate. Ex-Press was associated with a significantly lower frequency of hypotony and hyphema than Trab, with pooled ORs of 0.29 (0.13, 0.65) and 0.36 (0.13, 0.97), respectively. CONCLUSION: Ex-Press was associated with equivalent efficacy to Trab in lowering IOP. Comparable proportions of patients reached the IOP target with Ex-Press and Trab. Ex-Press was better tolerated than Trab. Public Library of Science 2013-05-31 /pmc/articles/PMC3669314/ /pubmed/23741296 http://dx.doi.org/10.1371/journal.pone.0063591 Text en © 2013 Wang et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Wang, Wei Zhou, Minwen Huang, Wenbin Zhang, Xiulan Ex-PRESS Implantation Versus Trabeculectomy in Uncontrolled Glaucoma: A Meta-Analysis |
title | Ex-PRESS Implantation Versus Trabeculectomy in Uncontrolled Glaucoma: A Meta-Analysis |
title_full | Ex-PRESS Implantation Versus Trabeculectomy in Uncontrolled Glaucoma: A Meta-Analysis |
title_fullStr | Ex-PRESS Implantation Versus Trabeculectomy in Uncontrolled Glaucoma: A Meta-Analysis |
title_full_unstemmed | Ex-PRESS Implantation Versus Trabeculectomy in Uncontrolled Glaucoma: A Meta-Analysis |
title_short | Ex-PRESS Implantation Versus Trabeculectomy in Uncontrolled Glaucoma: A Meta-Analysis |
title_sort | ex-press implantation versus trabeculectomy in uncontrolled glaucoma: a meta-analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3669314/ https://www.ncbi.nlm.nih.gov/pubmed/23741296 http://dx.doi.org/10.1371/journal.pone.0063591 |
work_keys_str_mv | AT wangwei expressimplantationversustrabeculectomyinuncontrolledglaucomaametaanalysis AT zhouminwen expressimplantationversustrabeculectomyinuncontrolledglaucomaametaanalysis AT huangwenbin expressimplantationversustrabeculectomyinuncontrolledglaucomaametaanalysis AT zhangxiulan expressimplantationversustrabeculectomyinuncontrolledglaucomaametaanalysis |