Prospective ECG-Triggered Coronary CT Angiography: Clinical Value of Noise-Based Tube Current Reduction Method with Iterative Reconstruction

OBJECTIVES: To evaluate the clinical value of noise-based tube current reduction method with iterative reconstruction for obtaining consistent image quality with dose optimization in prospective electrocardiogram (ECG)-triggered coronary CT angiography (CCTA). MATERIALS AND METHODS: We performed a p...

Descripción completa

Detalles Bibliográficos
Autores principales: Shen, Junlin, Du, Xiangying, Guo, Daode, Cao, Lizhen, Gao, Yan, Yang, Qi, Li, Pengyu, Liu, Jiabin, Li, Kuncheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3669389/
https://www.ncbi.nlm.nih.gov/pubmed/23741444
http://dx.doi.org/10.1371/journal.pone.0065025
_version_ 1782271748194959360
author Shen, Junlin
Du, Xiangying
Guo, Daode
Cao, Lizhen
Gao, Yan
Yang, Qi
Li, Pengyu
Liu, Jiabin
Li, Kuncheng
author_facet Shen, Junlin
Du, Xiangying
Guo, Daode
Cao, Lizhen
Gao, Yan
Yang, Qi
Li, Pengyu
Liu, Jiabin
Li, Kuncheng
author_sort Shen, Junlin
collection PubMed
description OBJECTIVES: To evaluate the clinical value of noise-based tube current reduction method with iterative reconstruction for obtaining consistent image quality with dose optimization in prospective electrocardiogram (ECG)-triggered coronary CT angiography (CCTA). MATERIALS AND METHODS: We performed a prospective randomized study evaluating 338 patients undergoing CCTA with prospective ECG-triggering. Patients were randomly assigned to fixed tube current with filtered back projection (Group 1, n = 113), noise-based tube current with filtered back projection (Group 2, n = 109) or with iterative reconstruction (Group 3, n = 116). Tube voltage was fixed at 120 kV. Qualitative image quality was rated on a 5-point scale (1 = impaired, to 5 = excellent, with 3–5 defined as diagnostic). Image noise and signal intensity were measured; signal-to-noise ratio was calculated; radiation dose parameters were recorded. Statistical analyses included one-way analysis of variance, chi-square test, Kruskal-Wallis test and multivariable linear regression. RESULTS: Image noise was maintained at the target value of 35HU with small interquartile range for Group 2 (35.00–35.03HU) and Group 3 (34.99–35.02HU), while from 28.73 to 37.87HU for Group 1. All images in the three groups were acceptable for diagnosis. A relative 20% and 51% reduction in effective dose for Group 2 (2.9 mSv) and Group 3 (1.8 mSv) were achieved compared with Group 1 (3.7 mSv). After adjustment for scan characteristics, iterative reconstruction was associated with 26% reduction in effective dose. CONCLUSION: Noise-based tube current reduction method with iterative reconstruction maintains image noise precisely at the desired level and achieves consistent image quality. Meanwhile, effective dose can be reduced by more than 50%.
format Online
Article
Text
id pubmed-3669389
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-36693892013-06-05 Prospective ECG-Triggered Coronary CT Angiography: Clinical Value of Noise-Based Tube Current Reduction Method with Iterative Reconstruction Shen, Junlin Du, Xiangying Guo, Daode Cao, Lizhen Gao, Yan Yang, Qi Li, Pengyu Liu, Jiabin Li, Kuncheng PLoS One Research Article OBJECTIVES: To evaluate the clinical value of noise-based tube current reduction method with iterative reconstruction for obtaining consistent image quality with dose optimization in prospective electrocardiogram (ECG)-triggered coronary CT angiography (CCTA). MATERIALS AND METHODS: We performed a prospective randomized study evaluating 338 patients undergoing CCTA with prospective ECG-triggering. Patients were randomly assigned to fixed tube current with filtered back projection (Group 1, n = 113), noise-based tube current with filtered back projection (Group 2, n = 109) or with iterative reconstruction (Group 3, n = 116). Tube voltage was fixed at 120 kV. Qualitative image quality was rated on a 5-point scale (1 = impaired, to 5 = excellent, with 3–5 defined as diagnostic). Image noise and signal intensity were measured; signal-to-noise ratio was calculated; radiation dose parameters were recorded. Statistical analyses included one-way analysis of variance, chi-square test, Kruskal-Wallis test and multivariable linear regression. RESULTS: Image noise was maintained at the target value of 35HU with small interquartile range for Group 2 (35.00–35.03HU) and Group 3 (34.99–35.02HU), while from 28.73 to 37.87HU for Group 1. All images in the three groups were acceptable for diagnosis. A relative 20% and 51% reduction in effective dose for Group 2 (2.9 mSv) and Group 3 (1.8 mSv) were achieved compared with Group 1 (3.7 mSv). After adjustment for scan characteristics, iterative reconstruction was associated with 26% reduction in effective dose. CONCLUSION: Noise-based tube current reduction method with iterative reconstruction maintains image noise precisely at the desired level and achieves consistent image quality. Meanwhile, effective dose can be reduced by more than 50%. Public Library of Science 2013-05-31 /pmc/articles/PMC3669389/ /pubmed/23741444 http://dx.doi.org/10.1371/journal.pone.0065025 Text en © 2013 Shen et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Shen, Junlin
Du, Xiangying
Guo, Daode
Cao, Lizhen
Gao, Yan
Yang, Qi
Li, Pengyu
Liu, Jiabin
Li, Kuncheng
Prospective ECG-Triggered Coronary CT Angiography: Clinical Value of Noise-Based Tube Current Reduction Method with Iterative Reconstruction
title Prospective ECG-Triggered Coronary CT Angiography: Clinical Value of Noise-Based Tube Current Reduction Method with Iterative Reconstruction
title_full Prospective ECG-Triggered Coronary CT Angiography: Clinical Value of Noise-Based Tube Current Reduction Method with Iterative Reconstruction
title_fullStr Prospective ECG-Triggered Coronary CT Angiography: Clinical Value of Noise-Based Tube Current Reduction Method with Iterative Reconstruction
title_full_unstemmed Prospective ECG-Triggered Coronary CT Angiography: Clinical Value of Noise-Based Tube Current Reduction Method with Iterative Reconstruction
title_short Prospective ECG-Triggered Coronary CT Angiography: Clinical Value of Noise-Based Tube Current Reduction Method with Iterative Reconstruction
title_sort prospective ecg-triggered coronary ct angiography: clinical value of noise-based tube current reduction method with iterative reconstruction
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3669389/
https://www.ncbi.nlm.nih.gov/pubmed/23741444
http://dx.doi.org/10.1371/journal.pone.0065025
work_keys_str_mv AT shenjunlin prospectiveecgtriggeredcoronaryctangiographyclinicalvalueofnoisebasedtubecurrentreductionmethodwithiterativereconstruction
AT duxiangying prospectiveecgtriggeredcoronaryctangiographyclinicalvalueofnoisebasedtubecurrentreductionmethodwithiterativereconstruction
AT guodaode prospectiveecgtriggeredcoronaryctangiographyclinicalvalueofnoisebasedtubecurrentreductionmethodwithiterativereconstruction
AT caolizhen prospectiveecgtriggeredcoronaryctangiographyclinicalvalueofnoisebasedtubecurrentreductionmethodwithiterativereconstruction
AT gaoyan prospectiveecgtriggeredcoronaryctangiographyclinicalvalueofnoisebasedtubecurrentreductionmethodwithiterativereconstruction
AT yangqi prospectiveecgtriggeredcoronaryctangiographyclinicalvalueofnoisebasedtubecurrentreductionmethodwithiterativereconstruction
AT lipengyu prospectiveecgtriggeredcoronaryctangiographyclinicalvalueofnoisebasedtubecurrentreductionmethodwithiterativereconstruction
AT liujiabin prospectiveecgtriggeredcoronaryctangiographyclinicalvalueofnoisebasedtubecurrentreductionmethodwithiterativereconstruction
AT likuncheng prospectiveecgtriggeredcoronaryctangiographyclinicalvalueofnoisebasedtubecurrentreductionmethodwithiterativereconstruction