Cargando…

Comparison of Anterior Segment Optical Tomography Parameters Measured Using a Semi-Automatic Software to Standard Clinical Instruments

OBJECTIVE: To compare anterior segment parameters measured using a semi-automatic software (Zhongshan Angle Assessment Program, ZAP) applied to anterior segment optical coherence tomography (AS-OCT) images, with commonly used instruments. METHODS: Cross-sectional study of a total of 1069 subjects (1...

Descripción completa

Detalles Bibliográficos
Autores principales: Ang, Marcus, Chong, Wesley, Huang, Huiqi, Tay, Wan Ting, Wong, Tien Yin, He, Ming-Guang, Aung, Tin, Mehta, Jodhbir S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3672133/
https://www.ncbi.nlm.nih.gov/pubmed/23750265
http://dx.doi.org/10.1371/journal.pone.0065559
_version_ 1782272078769029120
author Ang, Marcus
Chong, Wesley
Huang, Huiqi
Tay, Wan Ting
Wong, Tien Yin
He, Ming-Guang
Aung, Tin
Mehta, Jodhbir S.
author_facet Ang, Marcus
Chong, Wesley
Huang, Huiqi
Tay, Wan Ting
Wong, Tien Yin
He, Ming-Guang
Aung, Tin
Mehta, Jodhbir S.
author_sort Ang, Marcus
collection PubMed
description OBJECTIVE: To compare anterior segment parameters measured using a semi-automatic software (Zhongshan Angle Assessment Program, ZAP) applied to anterior segment optical coherence tomography (AS-OCT) images, with commonly used instruments. METHODS: Cross-sectional study of a total of 1069 subjects (1069 eyes) from three population-based studies of adults aged 40–80 years. All subjects underwent AS-OCT imaging and ZAP software was applied to determine anterior chamber depth (ACD), central corneal thickness (CCT), anterior and keratometry (K) – readings. These were compared to auto-refraction, keratometry and ocular biometry measured using an IOLMaster, ultrasound pachymeter and auto-refractor respectively. Agreements between AS-OCT (ZAP) and clinical instrument modalities were described using Bland-Altman, 95% limits of agreement (LOA). RESULTS: The mean age of our subjects was 56.9±9.5 years and 50.9% were male. The mean AS-OCT (ZAP) parameters of our study cohort were: ACD 3.29±0.35 mm, CCT 560.75±35.07 µm; K-reading 46.79±2.72 D. There was good agreement between the measurements from ZAP analysis and each instrument and no violations in the assumptions of the LOA; albeit with a systematic bias for each comparison: AS-OCT consistently measured a deeper ACD compared to IOLMaster (95% LOA −0.24, 0.55); and a thicker CCT for the AS-OCT compared to ultrasound pachymetry (16.8±0.53 µm 95% LOA −17.3, 50.8). AS-OCT had good agreement with auto-refractor with at least 95% of the measurements within the prediction interval (P value <0.001). CONCLUSION: This study demonstrates that there is good agreement between the measurements from the AS-OCT (ZAP) and conventional tools. However, small systematic biases remain that suggest that these measurement tools may not be interchanged.
format Online
Article
Text
id pubmed-3672133
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-36721332013-06-07 Comparison of Anterior Segment Optical Tomography Parameters Measured Using a Semi-Automatic Software to Standard Clinical Instruments Ang, Marcus Chong, Wesley Huang, Huiqi Tay, Wan Ting Wong, Tien Yin He, Ming-Guang Aung, Tin Mehta, Jodhbir S. PLoS One Research Article OBJECTIVE: To compare anterior segment parameters measured using a semi-automatic software (Zhongshan Angle Assessment Program, ZAP) applied to anterior segment optical coherence tomography (AS-OCT) images, with commonly used instruments. METHODS: Cross-sectional study of a total of 1069 subjects (1069 eyes) from three population-based studies of adults aged 40–80 years. All subjects underwent AS-OCT imaging and ZAP software was applied to determine anterior chamber depth (ACD), central corneal thickness (CCT), anterior and keratometry (K) – readings. These were compared to auto-refraction, keratometry and ocular biometry measured using an IOLMaster, ultrasound pachymeter and auto-refractor respectively. Agreements between AS-OCT (ZAP) and clinical instrument modalities were described using Bland-Altman, 95% limits of agreement (LOA). RESULTS: The mean age of our subjects was 56.9±9.5 years and 50.9% were male. The mean AS-OCT (ZAP) parameters of our study cohort were: ACD 3.29±0.35 mm, CCT 560.75±35.07 µm; K-reading 46.79±2.72 D. There was good agreement between the measurements from ZAP analysis and each instrument and no violations in the assumptions of the LOA; albeit with a systematic bias for each comparison: AS-OCT consistently measured a deeper ACD compared to IOLMaster (95% LOA −0.24, 0.55); and a thicker CCT for the AS-OCT compared to ultrasound pachymetry (16.8±0.53 µm 95% LOA −17.3, 50.8). AS-OCT had good agreement with auto-refractor with at least 95% of the measurements within the prediction interval (P value <0.001). CONCLUSION: This study demonstrates that there is good agreement between the measurements from the AS-OCT (ZAP) and conventional tools. However, small systematic biases remain that suggest that these measurement tools may not be interchanged. Public Library of Science 2013-06-04 /pmc/articles/PMC3672133/ /pubmed/23750265 http://dx.doi.org/10.1371/journal.pone.0065559 Text en © 2013 Ang et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Ang, Marcus
Chong, Wesley
Huang, Huiqi
Tay, Wan Ting
Wong, Tien Yin
He, Ming-Guang
Aung, Tin
Mehta, Jodhbir S.
Comparison of Anterior Segment Optical Tomography Parameters Measured Using a Semi-Automatic Software to Standard Clinical Instruments
title Comparison of Anterior Segment Optical Tomography Parameters Measured Using a Semi-Automatic Software to Standard Clinical Instruments
title_full Comparison of Anterior Segment Optical Tomography Parameters Measured Using a Semi-Automatic Software to Standard Clinical Instruments
title_fullStr Comparison of Anterior Segment Optical Tomography Parameters Measured Using a Semi-Automatic Software to Standard Clinical Instruments
title_full_unstemmed Comparison of Anterior Segment Optical Tomography Parameters Measured Using a Semi-Automatic Software to Standard Clinical Instruments
title_short Comparison of Anterior Segment Optical Tomography Parameters Measured Using a Semi-Automatic Software to Standard Clinical Instruments
title_sort comparison of anterior segment optical tomography parameters measured using a semi-automatic software to standard clinical instruments
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3672133/
https://www.ncbi.nlm.nih.gov/pubmed/23750265
http://dx.doi.org/10.1371/journal.pone.0065559
work_keys_str_mv AT angmarcus comparisonofanteriorsegmentopticaltomographyparametersmeasuredusingasemiautomaticsoftwaretostandardclinicalinstruments
AT chongwesley comparisonofanteriorsegmentopticaltomographyparametersmeasuredusingasemiautomaticsoftwaretostandardclinicalinstruments
AT huanghuiqi comparisonofanteriorsegmentopticaltomographyparametersmeasuredusingasemiautomaticsoftwaretostandardclinicalinstruments
AT taywanting comparisonofanteriorsegmentopticaltomographyparametersmeasuredusingasemiautomaticsoftwaretostandardclinicalinstruments
AT wongtienyin comparisonofanteriorsegmentopticaltomographyparametersmeasuredusingasemiautomaticsoftwaretostandardclinicalinstruments
AT hemingguang comparisonofanteriorsegmentopticaltomographyparametersmeasuredusingasemiautomaticsoftwaretostandardclinicalinstruments
AT aungtin comparisonofanteriorsegmentopticaltomographyparametersmeasuredusingasemiautomaticsoftwaretostandardclinicalinstruments
AT mehtajodhbirs comparisonofanteriorsegmentopticaltomographyparametersmeasuredusingasemiautomaticsoftwaretostandardclinicalinstruments