Cargando…

Accuracy of plasma sTREM-1 for sepsis diagnosis in systemic inflammatory patients: a systematic review and meta-analysis

INTRODUCTION: Early diagnosis of sepsis is vital to the clinical course and outcome of septic patients. Recently, soluble triggering receptor expressed on myeloid cells-1 (sTREM-1) appears to be a potential marker of infection. The objective of this systematic review and meta-analysis was to evaluat...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Youping, Wang, Fei, Fan, Xiaohua, Bao, Rui, Bo, Lulong, Li, Jinbao, Deng, Xiaoming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3672614/
https://www.ncbi.nlm.nih.gov/pubmed/23194114
http://dx.doi.org/10.1186/cc11884
_version_ 1782272137817489408
author Wu, Youping
Wang, Fei
Fan, Xiaohua
Bao, Rui
Bo, Lulong
Li, Jinbao
Deng, Xiaoming
author_facet Wu, Youping
Wang, Fei
Fan, Xiaohua
Bao, Rui
Bo, Lulong
Li, Jinbao
Deng, Xiaoming
author_sort Wu, Youping
collection PubMed
description INTRODUCTION: Early diagnosis of sepsis is vital to the clinical course and outcome of septic patients. Recently, soluble triggering receptor expressed on myeloid cells-1 (sTREM-1) appears to be a potential marker of infection. The objective of this systematic review and meta-analysis was to evaluate the accuracy of plasma sTREM-1 for sepsis diagnosis in systemic inflammatory patients. METHODS: A systematic literature search of PubMed, Embase and Cochrane Central Register of Controlled Trials was performed using specific search terms (up to 15 October 2012). Studies were included if they assessed the accuracy of plasma sTREM-1 for sepsis diagnosis in adult patients with systemic inflammatory response syndrome (SIRS) and provided sufficient information to construct a 2 X 2 contingency table. RESULTS: Eleven studies with a total of 1,795 patients were included. The pooled sensitivity and specificity was 79% (95% confidence interval (CI), 65 to 89) and 80% (95% CI, 69 to 88), respectively. The positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio were 4.0 (95% CI, 2.4 to 6.9), 0.26 (95% CI, 0.14 to 0.48), and 16 (95% CI, 5 to 46), respectively. The area under the curve of the summary receiver operator characteristic was 0.87 (95% CI, 0.84 to 0.89). Meta-regression analysis suggested that patient sample size and assay method were the main sources of heterogeneity. Publication bias was suggested by an asymmetrical funnel plot (P = 0.02). CONCLUSIONS: The present meta-analysis showed that plasma sTREM-1 had a moderate diagnostic performance in differentiating sepsis from SIRS. Accordingly, plasma sTREM-1 as a single marker was not sufficient for sepsis diagnosis in systemic inflammatory patients.
format Online
Article
Text
id pubmed-3672614
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-36726142013-06-10 Accuracy of plasma sTREM-1 for sepsis diagnosis in systemic inflammatory patients: a systematic review and meta-analysis Wu, Youping Wang, Fei Fan, Xiaohua Bao, Rui Bo, Lulong Li, Jinbao Deng, Xiaoming Crit Care Research INTRODUCTION: Early diagnosis of sepsis is vital to the clinical course and outcome of septic patients. Recently, soluble triggering receptor expressed on myeloid cells-1 (sTREM-1) appears to be a potential marker of infection. The objective of this systematic review and meta-analysis was to evaluate the accuracy of plasma sTREM-1 for sepsis diagnosis in systemic inflammatory patients. METHODS: A systematic literature search of PubMed, Embase and Cochrane Central Register of Controlled Trials was performed using specific search terms (up to 15 October 2012). Studies were included if they assessed the accuracy of plasma sTREM-1 for sepsis diagnosis in adult patients with systemic inflammatory response syndrome (SIRS) and provided sufficient information to construct a 2 X 2 contingency table. RESULTS: Eleven studies with a total of 1,795 patients were included. The pooled sensitivity and specificity was 79% (95% confidence interval (CI), 65 to 89) and 80% (95% CI, 69 to 88), respectively. The positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio were 4.0 (95% CI, 2.4 to 6.9), 0.26 (95% CI, 0.14 to 0.48), and 16 (95% CI, 5 to 46), respectively. The area under the curve of the summary receiver operator characteristic was 0.87 (95% CI, 0.84 to 0.89). Meta-regression analysis suggested that patient sample size and assay method were the main sources of heterogeneity. Publication bias was suggested by an asymmetrical funnel plot (P = 0.02). CONCLUSIONS: The present meta-analysis showed that plasma sTREM-1 had a moderate diagnostic performance in differentiating sepsis from SIRS. Accordingly, plasma sTREM-1 as a single marker was not sufficient for sepsis diagnosis in systemic inflammatory patients. BioMed Central 2012 2012-11-29 /pmc/articles/PMC3672614/ /pubmed/23194114 http://dx.doi.org/10.1186/cc11884 Text en Copyright ©2012 Wu et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Wu, Youping
Wang, Fei
Fan, Xiaohua
Bao, Rui
Bo, Lulong
Li, Jinbao
Deng, Xiaoming
Accuracy of plasma sTREM-1 for sepsis diagnosis in systemic inflammatory patients: a systematic review and meta-analysis
title Accuracy of plasma sTREM-1 for sepsis diagnosis in systemic inflammatory patients: a systematic review and meta-analysis
title_full Accuracy of plasma sTREM-1 for sepsis diagnosis in systemic inflammatory patients: a systematic review and meta-analysis
title_fullStr Accuracy of plasma sTREM-1 for sepsis diagnosis in systemic inflammatory patients: a systematic review and meta-analysis
title_full_unstemmed Accuracy of plasma sTREM-1 for sepsis diagnosis in systemic inflammatory patients: a systematic review and meta-analysis
title_short Accuracy of plasma sTREM-1 for sepsis diagnosis in systemic inflammatory patients: a systematic review and meta-analysis
title_sort accuracy of plasma strem-1 for sepsis diagnosis in systemic inflammatory patients: a systematic review and meta-analysis
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3672614/
https://www.ncbi.nlm.nih.gov/pubmed/23194114
http://dx.doi.org/10.1186/cc11884
work_keys_str_mv AT wuyouping accuracyofplasmastrem1forsepsisdiagnosisinsystemicinflammatorypatientsasystematicreviewandmetaanalysis
AT wangfei accuracyofplasmastrem1forsepsisdiagnosisinsystemicinflammatorypatientsasystematicreviewandmetaanalysis
AT fanxiaohua accuracyofplasmastrem1forsepsisdiagnosisinsystemicinflammatorypatientsasystematicreviewandmetaanalysis
AT baorui accuracyofplasmastrem1forsepsisdiagnosisinsystemicinflammatorypatientsasystematicreviewandmetaanalysis
AT bolulong accuracyofplasmastrem1forsepsisdiagnosisinsystemicinflammatorypatientsasystematicreviewandmetaanalysis
AT lijinbao accuracyofplasmastrem1forsepsisdiagnosisinsystemicinflammatorypatientsasystematicreviewandmetaanalysis
AT dengxiaoming accuracyofplasmastrem1forsepsisdiagnosisinsystemicinflammatorypatientsasystematicreviewandmetaanalysis