Development of Robust and Standardized Cantilever Sensors Based on Biotin/Neutravidin Coupling for Antibody Detection
A cantilever-based protein biosensor has been developed providing a customizable multilayer platform for the detection of antibodies. It consists of a biotin-terminated PEG layer pre-functionalized on the gold-coated cantilever surface, onto which NeutrAvidin is adsorbed through biotin/NeutrAvidin s...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3673136/ https://www.ncbi.nlm.nih.gov/pubmed/23604028 http://dx.doi.org/10.3390/s130405273 |
_version_ | 1782272217461030912 |
---|---|
author | Zhang, Jiayun Lang, Hans Peter Battiston, Felice Backmann, Natalija Huber, Francois Gerber, Christoph |
author_facet | Zhang, Jiayun Lang, Hans Peter Battiston, Felice Backmann, Natalija Huber, Francois Gerber, Christoph |
author_sort | Zhang, Jiayun |
collection | PubMed |
description | A cantilever-based protein biosensor has been developed providing a customizable multilayer platform for the detection of antibodies. It consists of a biotin-terminated PEG layer pre-functionalized on the gold-coated cantilever surface, onto which NeutrAvidin is adsorbed through biotin/NeutrAvidin specific binding. NeutrAvidin is used as a bridge layer between the biotin-coated surface and the biotinylated biomolecules, such as biotinylated bovine serum albumin (biotinylated BSA), forming a multilayer sensor for direct antibody capture. The cantilever biosensor has been successfully applied to the detection of mouse anti-BSA (m-IgG) and sheep anti-BSA(s-IgG) antibodies. As expected, the average differential surface stress signals of about 5.7 ± 0.8 × 10(−3) N/m are very similar for BSA/m-IgG and BSA/s-IgG binding, i.e., they are independent of the origin of the antibody. A statistic evaluation of 112 response curves confirms that the multilayer protein cantilever biosensor shows high reproducibility. As a control test, a biotinylated maltose binding protein was used for detecting specificity of IgG, the result shows a signal of bBSA layer in response to antibody is 5.8 × 10(−3) N/m compared to bMBP. The pre-functionalized biotin/PEG cantilever surface is found to show a long shelf-life of at least 40 days and retains its responsivity of above 70% of the signal when stored in PBS buffer at 4 °C. The protein cantilever biosensor represents a rapid, label-free, sensitive and reliable detection technique for a real-time protein assay. |
format | Online Article Text |
id | pubmed-3673136 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-36731362013-06-19 Development of Robust and Standardized Cantilever Sensors Based on Biotin/Neutravidin Coupling for Antibody Detection Zhang, Jiayun Lang, Hans Peter Battiston, Felice Backmann, Natalija Huber, Francois Gerber, Christoph Sensors (Basel) Article A cantilever-based protein biosensor has been developed providing a customizable multilayer platform for the detection of antibodies. It consists of a biotin-terminated PEG layer pre-functionalized on the gold-coated cantilever surface, onto which NeutrAvidin is adsorbed through biotin/NeutrAvidin specific binding. NeutrAvidin is used as a bridge layer between the biotin-coated surface and the biotinylated biomolecules, such as biotinylated bovine serum albumin (biotinylated BSA), forming a multilayer sensor for direct antibody capture. The cantilever biosensor has been successfully applied to the detection of mouse anti-BSA (m-IgG) and sheep anti-BSA(s-IgG) antibodies. As expected, the average differential surface stress signals of about 5.7 ± 0.8 × 10(−3) N/m are very similar for BSA/m-IgG and BSA/s-IgG binding, i.e., they are independent of the origin of the antibody. A statistic evaluation of 112 response curves confirms that the multilayer protein cantilever biosensor shows high reproducibility. As a control test, a biotinylated maltose binding protein was used for detecting specificity of IgG, the result shows a signal of bBSA layer in response to antibody is 5.8 × 10(−3) N/m compared to bMBP. The pre-functionalized biotin/PEG cantilever surface is found to show a long shelf-life of at least 40 days and retains its responsivity of above 70% of the signal when stored in PBS buffer at 4 °C. The protein cantilever biosensor represents a rapid, label-free, sensitive and reliable detection technique for a real-time protein assay. Molecular Diversity Preservation International (MDPI) 2013-04-19 /pmc/articles/PMC3673136/ /pubmed/23604028 http://dx.doi.org/10.3390/s130405273 Text en © 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Zhang, Jiayun Lang, Hans Peter Battiston, Felice Backmann, Natalija Huber, Francois Gerber, Christoph Development of Robust and Standardized Cantilever Sensors Based on Biotin/Neutravidin Coupling for Antibody Detection |
title | Development of Robust and Standardized Cantilever Sensors Based on Biotin/Neutravidin Coupling for Antibody Detection |
title_full | Development of Robust and Standardized Cantilever Sensors Based on Biotin/Neutravidin Coupling for Antibody Detection |
title_fullStr | Development of Robust and Standardized Cantilever Sensors Based on Biotin/Neutravidin Coupling for Antibody Detection |
title_full_unstemmed | Development of Robust and Standardized Cantilever Sensors Based on Biotin/Neutravidin Coupling for Antibody Detection |
title_short | Development of Robust and Standardized Cantilever Sensors Based on Biotin/Neutravidin Coupling for Antibody Detection |
title_sort | development of robust and standardized cantilever sensors based on biotin/neutravidin coupling for antibody detection |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3673136/ https://www.ncbi.nlm.nih.gov/pubmed/23604028 http://dx.doi.org/10.3390/s130405273 |
work_keys_str_mv | AT zhangjiayun developmentofrobustandstandardizedcantileversensorsbasedonbiotinneutravidincouplingforantibodydetection AT langhanspeter developmentofrobustandstandardizedcantileversensorsbasedonbiotinneutravidincouplingforantibodydetection AT battistonfelice developmentofrobustandstandardizedcantileversensorsbasedonbiotinneutravidincouplingforantibodydetection AT backmannnatalija developmentofrobustandstandardizedcantileversensorsbasedonbiotinneutravidincouplingforantibodydetection AT huberfrancois developmentofrobustandstandardizedcantileversensorsbasedonbiotinneutravidincouplingforantibodydetection AT gerberchristoph developmentofrobustandstandardizedcantileversensorsbasedonbiotinneutravidincouplingforantibodydetection |