Cargando…

Development of Robust and Standardized Cantilever Sensors Based on Biotin/Neutravidin Coupling for Antibody Detection

A cantilever-based protein biosensor has been developed providing a customizable multilayer platform for the detection of antibodies. It consists of a biotin-terminated PEG layer pre-functionalized on the gold-coated cantilever surface, onto which NeutrAvidin is adsorbed through biotin/NeutrAvidin s...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Jiayun, Lang, Hans Peter, Battiston, Felice, Backmann, Natalija, Huber, Francois, Gerber, Christoph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3673136/
https://www.ncbi.nlm.nih.gov/pubmed/23604028
http://dx.doi.org/10.3390/s130405273
_version_ 1782272217461030912
author Zhang, Jiayun
Lang, Hans Peter
Battiston, Felice
Backmann, Natalija
Huber, Francois
Gerber, Christoph
author_facet Zhang, Jiayun
Lang, Hans Peter
Battiston, Felice
Backmann, Natalija
Huber, Francois
Gerber, Christoph
author_sort Zhang, Jiayun
collection PubMed
description A cantilever-based protein biosensor has been developed providing a customizable multilayer platform for the detection of antibodies. It consists of a biotin-terminated PEG layer pre-functionalized on the gold-coated cantilever surface, onto which NeutrAvidin is adsorbed through biotin/NeutrAvidin specific binding. NeutrAvidin is used as a bridge layer between the biotin-coated surface and the biotinylated biomolecules, such as biotinylated bovine serum albumin (biotinylated BSA), forming a multilayer sensor for direct antibody capture. The cantilever biosensor has been successfully applied to the detection of mouse anti-BSA (m-IgG) and sheep anti-BSA(s-IgG) antibodies. As expected, the average differential surface stress signals of about 5.7 ± 0.8 × 10(−3) N/m are very similar for BSA/m-IgG and BSA/s-IgG binding, i.e., they are independent of the origin of the antibody. A statistic evaluation of 112 response curves confirms that the multilayer protein cantilever biosensor shows high reproducibility. As a control test, a biotinylated maltose binding protein was used for detecting specificity of IgG, the result shows a signal of bBSA layer in response to antibody is 5.8 × 10(−3) N/m compared to bMBP. The pre-functionalized biotin/PEG cantilever surface is found to show a long shelf-life of at least 40 days and retains its responsivity of above 70% of the signal when stored in PBS buffer at 4 °C. The protein cantilever biosensor represents a rapid, label-free, sensitive and reliable detection technique for a real-time protein assay.
format Online
Article
Text
id pubmed-3673136
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-36731362013-06-19 Development of Robust and Standardized Cantilever Sensors Based on Biotin/Neutravidin Coupling for Antibody Detection Zhang, Jiayun Lang, Hans Peter Battiston, Felice Backmann, Natalija Huber, Francois Gerber, Christoph Sensors (Basel) Article A cantilever-based protein biosensor has been developed providing a customizable multilayer platform for the detection of antibodies. It consists of a biotin-terminated PEG layer pre-functionalized on the gold-coated cantilever surface, onto which NeutrAvidin is adsorbed through biotin/NeutrAvidin specific binding. NeutrAvidin is used as a bridge layer between the biotin-coated surface and the biotinylated biomolecules, such as biotinylated bovine serum albumin (biotinylated BSA), forming a multilayer sensor for direct antibody capture. The cantilever biosensor has been successfully applied to the detection of mouse anti-BSA (m-IgG) and sheep anti-BSA(s-IgG) antibodies. As expected, the average differential surface stress signals of about 5.7 ± 0.8 × 10(−3) N/m are very similar for BSA/m-IgG and BSA/s-IgG binding, i.e., they are independent of the origin of the antibody. A statistic evaluation of 112 response curves confirms that the multilayer protein cantilever biosensor shows high reproducibility. As a control test, a biotinylated maltose binding protein was used for detecting specificity of IgG, the result shows a signal of bBSA layer in response to antibody is 5.8 × 10(−3) N/m compared to bMBP. The pre-functionalized biotin/PEG cantilever surface is found to show a long shelf-life of at least 40 days and retains its responsivity of above 70% of the signal when stored in PBS buffer at 4 °C. The protein cantilever biosensor represents a rapid, label-free, sensitive and reliable detection technique for a real-time protein assay. Molecular Diversity Preservation International (MDPI) 2013-04-19 /pmc/articles/PMC3673136/ /pubmed/23604028 http://dx.doi.org/10.3390/s130405273 Text en © 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Zhang, Jiayun
Lang, Hans Peter
Battiston, Felice
Backmann, Natalija
Huber, Francois
Gerber, Christoph
Development of Robust and Standardized Cantilever Sensors Based on Biotin/Neutravidin Coupling for Antibody Detection
title Development of Robust and Standardized Cantilever Sensors Based on Biotin/Neutravidin Coupling for Antibody Detection
title_full Development of Robust and Standardized Cantilever Sensors Based on Biotin/Neutravidin Coupling for Antibody Detection
title_fullStr Development of Robust and Standardized Cantilever Sensors Based on Biotin/Neutravidin Coupling for Antibody Detection
title_full_unstemmed Development of Robust and Standardized Cantilever Sensors Based on Biotin/Neutravidin Coupling for Antibody Detection
title_short Development of Robust and Standardized Cantilever Sensors Based on Biotin/Neutravidin Coupling for Antibody Detection
title_sort development of robust and standardized cantilever sensors based on biotin/neutravidin coupling for antibody detection
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3673136/
https://www.ncbi.nlm.nih.gov/pubmed/23604028
http://dx.doi.org/10.3390/s130405273
work_keys_str_mv AT zhangjiayun developmentofrobustandstandardizedcantileversensorsbasedonbiotinneutravidincouplingforantibodydetection
AT langhanspeter developmentofrobustandstandardizedcantileversensorsbasedonbiotinneutravidincouplingforantibodydetection
AT battistonfelice developmentofrobustandstandardizedcantileversensorsbasedonbiotinneutravidincouplingforantibodydetection
AT backmannnatalija developmentofrobustandstandardizedcantileversensorsbasedonbiotinneutravidincouplingforantibodydetection
AT huberfrancois developmentofrobustandstandardizedcantileversensorsbasedonbiotinneutravidincouplingforantibodydetection
AT gerberchristoph developmentofrobustandstandardizedcantileversensorsbasedonbiotinneutravidincouplingforantibodydetection