Cargando…

Validation of Noninvasive MOEMS-Assisted Measurement System Based on CCD Sensor for Radial Pulse Analysis

Examination of wrist radial pulse is a noninvasive diagnostic method, which occupies a very important position in Traditional Chinese Medicine. It is based on manual palpation and therefore relies largely on the practitioner′s subjective technical skills and judgment. Consequently, it lacks reliabil...

Descripción completa

Detalles Bibliográficos
Autores principales: Malinauskas, Karolis, Palevicius, Paulius, Ragulskis, Minvydas, Ostasevicius, Vytautas, Dauksevicius, Rolanas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3673142/
https://www.ncbi.nlm.nih.gov/pubmed/23609803
http://dx.doi.org/10.3390/s130405368
_version_ 1782272218829422592
author Malinauskas, Karolis
Palevicius, Paulius
Ragulskis, Minvydas
Ostasevicius, Vytautas
Dauksevicius, Rolanas
author_facet Malinauskas, Karolis
Palevicius, Paulius
Ragulskis, Minvydas
Ostasevicius, Vytautas
Dauksevicius, Rolanas
author_sort Malinauskas, Karolis
collection PubMed
description Examination of wrist radial pulse is a noninvasive diagnostic method, which occupies a very important position in Traditional Chinese Medicine. It is based on manual palpation and therefore relies largely on the practitioner′s subjective technical skills and judgment. Consequently, it lacks reliability and consistency, which limits practical applications in clinical medicine. Thus, quantifiable characterization of the wrist pulse diagnosis method is a prerequisite for its further development and widespread use. This paper reports application of a noninvasive CCD sensor-based hybrid measurement system for radial pulse signal analysis. First, artery wall deformations caused by the blood flow are calibrated with a laser triangulation displacement sensor, following by the measurement of the deformations with projection moiré method. Different input pressures and fluids of various viscosities are used in the assembled artificial blood flow system in order to test the performance of laser triangulation technique with detection sensitivity enhancement through microfabricated retroreflective optical element placed on a synthetic vascular graft. Subsequently, the applicability of double-exposure whole-field projection moiré technique for registration of blood flow pulses is considered: a computational model and representative example are provided, followed by in vitro experiment performed on a vascular graft with artificial skin atop, which validates the suitability of the technique for characterization of skin surface deformations caused by the radial pulsation.
format Online
Article
Text
id pubmed-3673142
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-36731422013-06-19 Validation of Noninvasive MOEMS-Assisted Measurement System Based on CCD Sensor for Radial Pulse Analysis Malinauskas, Karolis Palevicius, Paulius Ragulskis, Minvydas Ostasevicius, Vytautas Dauksevicius, Rolanas Sensors (Basel) Article Examination of wrist radial pulse is a noninvasive diagnostic method, which occupies a very important position in Traditional Chinese Medicine. It is based on manual palpation and therefore relies largely on the practitioner′s subjective technical skills and judgment. Consequently, it lacks reliability and consistency, which limits practical applications in clinical medicine. Thus, quantifiable characterization of the wrist pulse diagnosis method is a prerequisite for its further development and widespread use. This paper reports application of a noninvasive CCD sensor-based hybrid measurement system for radial pulse signal analysis. First, artery wall deformations caused by the blood flow are calibrated with a laser triangulation displacement sensor, following by the measurement of the deformations with projection moiré method. Different input pressures and fluids of various viscosities are used in the assembled artificial blood flow system in order to test the performance of laser triangulation technique with detection sensitivity enhancement through microfabricated retroreflective optical element placed on a synthetic vascular graft. Subsequently, the applicability of double-exposure whole-field projection moiré technique for registration of blood flow pulses is considered: a computational model and representative example are provided, followed by in vitro experiment performed on a vascular graft with artificial skin atop, which validates the suitability of the technique for characterization of skin surface deformations caused by the radial pulsation. Molecular Diversity Preservation International (MDPI) 2013-04-22 /pmc/articles/PMC3673142/ /pubmed/23609803 http://dx.doi.org/10.3390/s130405368 Text en © 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Malinauskas, Karolis
Palevicius, Paulius
Ragulskis, Minvydas
Ostasevicius, Vytautas
Dauksevicius, Rolanas
Validation of Noninvasive MOEMS-Assisted Measurement System Based on CCD Sensor for Radial Pulse Analysis
title Validation of Noninvasive MOEMS-Assisted Measurement System Based on CCD Sensor for Radial Pulse Analysis
title_full Validation of Noninvasive MOEMS-Assisted Measurement System Based on CCD Sensor for Radial Pulse Analysis
title_fullStr Validation of Noninvasive MOEMS-Assisted Measurement System Based on CCD Sensor for Radial Pulse Analysis
title_full_unstemmed Validation of Noninvasive MOEMS-Assisted Measurement System Based on CCD Sensor for Radial Pulse Analysis
title_short Validation of Noninvasive MOEMS-Assisted Measurement System Based on CCD Sensor for Radial Pulse Analysis
title_sort validation of noninvasive moems-assisted measurement system based on ccd sensor for radial pulse analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3673142/
https://www.ncbi.nlm.nih.gov/pubmed/23609803
http://dx.doi.org/10.3390/s130405368
work_keys_str_mv AT malinauskaskarolis validationofnoninvasivemoemsassistedmeasurementsystembasedonccdsensorforradialpulseanalysis
AT paleviciuspaulius validationofnoninvasivemoemsassistedmeasurementsystembasedonccdsensorforradialpulseanalysis
AT ragulskisminvydas validationofnoninvasivemoemsassistedmeasurementsystembasedonccdsensorforradialpulseanalysis
AT ostaseviciusvytautas validationofnoninvasivemoemsassistedmeasurementsystembasedonccdsensorforradialpulseanalysis
AT daukseviciusrolanas validationofnoninvasivemoemsassistedmeasurementsystembasedonccdsensorforradialpulseanalysis