Conductometric Microbiosensors for Environmental Monitoring
This review presents the principles of conductometric measurements in ionic media and the equivalent electrical circuits of different designs for conductometric measurements. These types of measurements were first applied for monitoring biocatalytic reactions. The use of conductometric microtransduc...
Autores principales: | Jaffrezic-Renault, Nicole, Dzyadevych, Sergei V. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3673432/ https://www.ncbi.nlm.nih.gov/pubmed/27879836 |
Ejemplares similares
-
Nanosized zeolites as a perspective material for conductometric biosensors creation
por: Kucherenko, Ivan, et al.
Publicado: (2015) -
Enhanced Response of a Proteinase K-Based Conductometric Biosensor Using Nanoparticles
por: Nouira, Wided, et al.
Publicado: (2014) -
Sensitive impedimetric biosensor for direct detection of diazinon based on lipases
por: Zehani, Nedjla, et al.
Publicado: (2014) -
A Sensitive Micro Conductometric Ethanol Sensor Based on an Alcohol Dehydrogenase-Gold Nanoparticle Chitosan Composite
por: Madaci, Anis, et al.
Publicado: (2023) -
Conductometric Sensors for Monitoring Degradation of Automotive Engine Oil(†)
por: Latif, Usman, et al.
Publicado: (2011)