Cargando…
Effect of span length on the fit of zirconia framework fabricated using CAD/CAM system
PURPOSE: The purpose of this study was to evaluate the effect of the span length on the fit of zirconia framework fabricated using CAD/CAM system. MATERIALS AND METHODS: Abutments for single, 4-unit and 6-unit fixed partial prostheses were fabricated. Ten zirconia frameworks were fabricated for each...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3675283/ https://www.ncbi.nlm.nih.gov/pubmed/23755336 http://dx.doi.org/10.4047/jap.2013.5.2.118 |
_version_ | 1782272501973254144 |
---|---|
author | Lee, Jeong-Yol Choi, Sang-Jin Kim, Min-Soo Kim, Ha-Young Kim, Young-Soo Shin, Sang-Wan |
author_facet | Lee, Jeong-Yol Choi, Sang-Jin Kim, Min-Soo Kim, Ha-Young Kim, Young-Soo Shin, Sang-Wan |
author_sort | Lee, Jeong-Yol |
collection | PubMed |
description | PURPOSE: The purpose of this study was to evaluate the effect of the span length on the fit of zirconia framework fabricated using CAD/CAM system. MATERIALS AND METHODS: Abutments for single, 4-unit and 6-unit fixed partial prostheses were fabricated. Ten zirconia frameworks were fabricated for each group. The marginal and internal gap were presented by means of replica technique and measured by measuring microscope (AXIO®, Carl Zeiss, Rochester, NY) and software (I-solution®, IMT i-solution Inc., Vancouver, BC, Canada). The results were statistically analyzed by multivariate analysis test and Dunnett T3 test for post hoc test (α=.05). RESULTS: There were statistically significant differences at 2, 4, 7, 8 points (mesio-distal section) and b, d, e, f, g (labio-lingual section). In some marginal reference points of 6-unit group (P<.05), the marginal gap were larger than 120 µm. CONCLUSION: Span length of zirconia core may have an influence on marginal and internal fit. Within the limitation of this study, the increase of span length of zirconia framework of 6 or more-unit fixed partial denture may decrease the marginal and internal fit. |
format | Online Article Text |
id | pubmed-3675283 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | The Korean Academy of Prosthodontics |
record_format | MEDLINE/PubMed |
spelling | pubmed-36752832013-06-10 Effect of span length on the fit of zirconia framework fabricated using CAD/CAM system Lee, Jeong-Yol Choi, Sang-Jin Kim, Min-Soo Kim, Ha-Young Kim, Young-Soo Shin, Sang-Wan J Adv Prosthodont Original Article PURPOSE: The purpose of this study was to evaluate the effect of the span length on the fit of zirconia framework fabricated using CAD/CAM system. MATERIALS AND METHODS: Abutments for single, 4-unit and 6-unit fixed partial prostheses were fabricated. Ten zirconia frameworks were fabricated for each group. The marginal and internal gap were presented by means of replica technique and measured by measuring microscope (AXIO®, Carl Zeiss, Rochester, NY) and software (I-solution®, IMT i-solution Inc., Vancouver, BC, Canada). The results were statistically analyzed by multivariate analysis test and Dunnett T3 test for post hoc test (α=.05). RESULTS: There were statistically significant differences at 2, 4, 7, 8 points (mesio-distal section) and b, d, e, f, g (labio-lingual section). In some marginal reference points of 6-unit group (P<.05), the marginal gap were larger than 120 µm. CONCLUSION: Span length of zirconia core may have an influence on marginal and internal fit. Within the limitation of this study, the increase of span length of zirconia framework of 6 or more-unit fixed partial denture may decrease the marginal and internal fit. The Korean Academy of Prosthodontics 2013-05 2013-05-30 /pmc/articles/PMC3675283/ /pubmed/23755336 http://dx.doi.org/10.4047/jap.2013.5.2.118 Text en © 2013 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Jeong-Yol Choi, Sang-Jin Kim, Min-Soo Kim, Ha-Young Kim, Young-Soo Shin, Sang-Wan Effect of span length on the fit of zirconia framework fabricated using CAD/CAM system |
title | Effect of span length on the fit of zirconia framework fabricated using CAD/CAM system |
title_full | Effect of span length on the fit of zirconia framework fabricated using CAD/CAM system |
title_fullStr | Effect of span length on the fit of zirconia framework fabricated using CAD/CAM system |
title_full_unstemmed | Effect of span length on the fit of zirconia framework fabricated using CAD/CAM system |
title_short | Effect of span length on the fit of zirconia framework fabricated using CAD/CAM system |
title_sort | effect of span length on the fit of zirconia framework fabricated using cad/cam system |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3675283/ https://www.ncbi.nlm.nih.gov/pubmed/23755336 http://dx.doi.org/10.4047/jap.2013.5.2.118 |
work_keys_str_mv | AT leejeongyol effectofspanlengthonthefitofzirconiaframeworkfabricatedusingcadcamsystem AT choisangjin effectofspanlengthonthefitofzirconiaframeworkfabricatedusingcadcamsystem AT kimminsoo effectofspanlengthonthefitofzirconiaframeworkfabricatedusingcadcamsystem AT kimhayoung effectofspanlengthonthefitofzirconiaframeworkfabricatedusingcadcamsystem AT kimyoungsoo effectofspanlengthonthefitofzirconiaframeworkfabricatedusingcadcamsystem AT shinsangwan effectofspanlengthonthefitofzirconiaframeworkfabricatedusingcadcamsystem |