Cargando…
Non-Invasive Glucose Measurement by Use of Metabolic Heat Conformation Method
A non-invasive glucose measurement system based on the method of metabolic heat conformation (MHC) is presented in this paper. This system consists of three temperature sensors, two humidity sensors, an infrared sensor and an optical measurement device. The glucose level can be deduced from the quan...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3675547/ https://www.ncbi.nlm.nih.gov/pubmed/27879881 http://dx.doi.org/10.3390/s8053335 |
_version_ | 1782476114503925760 |
---|---|
author | Tang, Fei Wang, Xiaohao Wang, Dongsheng Li, Junfeng |
author_facet | Tang, Fei Wang, Xiaohao Wang, Dongsheng Li, Junfeng |
author_sort | Tang, Fei |
collection | PubMed |
description | A non-invasive glucose measurement system based on the method of metabolic heat conformation (MHC) is presented in this paper. This system consists of three temperature sensors, two humidity sensors, an infrared sensor and an optical measurement device. The glucose level can be deduced from the quantity of heat dissipation, blood flow rate of local tissue and degree of blood oxygen saturation. The methodology of the data process and the measurement error are also analyzed. The system is applied in a primary clinical test. Compared with the results of a commercial automated chemistry analyzer, the correlation coefficient of the collected data from the system is 0.856. Result shows that the correlation coefficient improves when the factor of heat dissipated by evaporation of the skin is added in. A non-invasive method of measuring the blood flow rate of local tissue by heat transmission between skin and contacted conductor is also introduced. Theoretical derivation and numerical simulation are completed as well. The so-called normalized difference mean (NDM) is chosen to express the quantity of the blood flow rate. The correlation coefficient between the blood flow rates by this method and the results of a Doppler blood flow meter is equal to 0.914. |
format | Online Article Text |
id | pubmed-3675547 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-36755472013-06-19 Non-Invasive Glucose Measurement by Use of Metabolic Heat Conformation Method Tang, Fei Wang, Xiaohao Wang, Dongsheng Li, Junfeng Sensors (Basel) Article A non-invasive glucose measurement system based on the method of metabolic heat conformation (MHC) is presented in this paper. This system consists of three temperature sensors, two humidity sensors, an infrared sensor and an optical measurement device. The glucose level can be deduced from the quantity of heat dissipation, blood flow rate of local tissue and degree of blood oxygen saturation. The methodology of the data process and the measurement error are also analyzed. The system is applied in a primary clinical test. Compared with the results of a commercial automated chemistry analyzer, the correlation coefficient of the collected data from the system is 0.856. Result shows that the correlation coefficient improves when the factor of heat dissipated by evaporation of the skin is added in. A non-invasive method of measuring the blood flow rate of local tissue by heat transmission between skin and contacted conductor is also introduced. Theoretical derivation and numerical simulation are completed as well. The so-called normalized difference mean (NDM) is chosen to express the quantity of the blood flow rate. The correlation coefficient between the blood flow rates by this method and the results of a Doppler blood flow meter is equal to 0.914. Molecular Diversity Preservation International (MDPI) 2008-05-21 /pmc/articles/PMC3675547/ /pubmed/27879881 http://dx.doi.org/10.3390/s8053335 Text en © 2008 by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland. This article is an open-access article distributed under the terms and conditions of the CreativeCommons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Tang, Fei Wang, Xiaohao Wang, Dongsheng Li, Junfeng Non-Invasive Glucose Measurement by Use of Metabolic Heat Conformation Method |
title | Non-Invasive Glucose Measurement by Use of Metabolic Heat Conformation Method |
title_full | Non-Invasive Glucose Measurement by Use of Metabolic Heat Conformation Method |
title_fullStr | Non-Invasive Glucose Measurement by Use of Metabolic Heat Conformation Method |
title_full_unstemmed | Non-Invasive Glucose Measurement by Use of Metabolic Heat Conformation Method |
title_short | Non-Invasive Glucose Measurement by Use of Metabolic Heat Conformation Method |
title_sort | non-invasive glucose measurement by use of metabolic heat conformation method |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3675547/ https://www.ncbi.nlm.nih.gov/pubmed/27879881 http://dx.doi.org/10.3390/s8053335 |
work_keys_str_mv | AT tangfei noninvasiveglucosemeasurementbyuseofmetabolicheatconformationmethod AT wangxiaohao noninvasiveglucosemeasurementbyuseofmetabolicheatconformationmethod AT wangdongsheng noninvasiveglucosemeasurementbyuseofmetabolicheatconformationmethod AT lijunfeng noninvasiveglucosemeasurementbyuseofmetabolicheatconformationmethod |