Cargando…
Frequency multiplexed long range swept source optical coherence tomography
We present a novel swept source optical coherence tomography configuration, equipped with acousto-optic deflectors that can be used to simultaneously acquire multiple B-scans originating from different depths. The sensitivity range of the configuration is evaluated while acquiring five simultaneous...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Optical Society of America
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3675859/ https://www.ncbi.nlm.nih.gov/pubmed/23760762 http://dx.doi.org/10.1364/BOE.4.000778 |
_version_ | 1782272606289788928 |
---|---|
author | Zurauskas, Mantas Bradu, Adrian Podoleanu, Adrian Gh. |
author_facet | Zurauskas, Mantas Bradu, Adrian Podoleanu, Adrian Gh. |
author_sort | Zurauskas, Mantas |
collection | PubMed |
description | We present a novel swept source optical coherence tomography configuration, equipped with acousto-optic deflectors that can be used to simultaneously acquire multiple B-scans originating from different depths. The sensitivity range of the configuration is evaluated while acquiring five simultaneous B-scans. Then the configuration is employed to demonstrate long range B-scan imaging by combining two simultaneous B-scans from a mouse head sample. |
format | Online Article Text |
id | pubmed-3675859 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Optical Society of America |
record_format | MEDLINE/PubMed |
spelling | pubmed-36758592013-06-11 Frequency multiplexed long range swept source optical coherence tomography Zurauskas, Mantas Bradu, Adrian Podoleanu, Adrian Gh. Biomed Opt Express Research-Article We present a novel swept source optical coherence tomography configuration, equipped with acousto-optic deflectors that can be used to simultaneously acquire multiple B-scans originating from different depths. The sensitivity range of the configuration is evaluated while acquiring five simultaneous B-scans. Then the configuration is employed to demonstrate long range B-scan imaging by combining two simultaneous B-scans from a mouse head sample. Optical Society of America 2013-05-02 /pmc/articles/PMC3675859/ /pubmed/23760762 http://dx.doi.org/10.1364/BOE.4.000778 Text en ©2013 Optical Society of America author-open |
spellingShingle | Research-Article Zurauskas, Mantas Bradu, Adrian Podoleanu, Adrian Gh. Frequency multiplexed long range swept source optical coherence tomography |
title | Frequency multiplexed long range swept source optical coherence
tomography |
title_full | Frequency multiplexed long range swept source optical coherence
tomography |
title_fullStr | Frequency multiplexed long range swept source optical coherence
tomography |
title_full_unstemmed | Frequency multiplexed long range swept source optical coherence
tomography |
title_short | Frequency multiplexed long range swept source optical coherence
tomography |
title_sort | frequency multiplexed long range swept source optical coherence
tomography |
topic | Research-Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3675859/ https://www.ncbi.nlm.nih.gov/pubmed/23760762 http://dx.doi.org/10.1364/BOE.4.000778 |
work_keys_str_mv | AT zurauskasmantas frequencymultiplexedlongrangesweptsourceopticalcoherencetomography AT braduadrian frequencymultiplexedlongrangesweptsourceopticalcoherencetomography AT podoleanuadriangh frequencymultiplexedlongrangesweptsourceopticalcoherencetomography |