Evaluation of ECHO PS Positioning System in a Porcine Model of Simulated Laparoscopic Ventral Hernia Repair
Purpose. Operative efficiency improvements for laparoscopic ventral hernia repair (LVHR) have focused on reducing operative time while maintaining overall repair efficacy. Our objective was to evaluate procedure time and positioning accuracy of an inflatable mesh positioning device (Echo PS Position...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3676964/ https://www.ncbi.nlm.nih.gov/pubmed/23762628 http://dx.doi.org/10.1155/2013/862549 |
_version_ | 1782272689858150400 |
---|---|
author | Hanna, Erin M. Voeller, Guy R. Roth, J. Scott Scott, Jeffrey R. Gagne, Darcy H. Iannitti, David A. |
author_facet | Hanna, Erin M. Voeller, Guy R. Roth, J. Scott Scott, Jeffrey R. Gagne, Darcy H. Iannitti, David A. |
author_sort | Hanna, Erin M. |
collection | PubMed |
description | Purpose. Operative efficiency improvements for laparoscopic ventral hernia repair (LVHR) have focused on reducing operative time while maintaining overall repair efficacy. Our objective was to evaluate procedure time and positioning accuracy of an inflatable mesh positioning device (Echo PS Positioning System), as compared to a standard transfascial suture technique, using a porcine model of simulated LVHR. Methods. The study population consisted of seventeen general surgeons (n = 17) that performed simulated LVHR on seventeen (n = 17) female Yorkshire pigs using two implantation techniques: (1) Ventralight ST Mesh + Echo PS Positioning System (Echo PS) and (2) Ventralight ST Mesh + transfascial sutures (TSs). Procedure time and mesh centering accuracy overtop of a simulated surgical defect were evaluated. Results. Echo PS demonstrated a 38.9% reduction in the overall procedure time, as compared to TS. During mesh preparation and positioning, Echo PS demonstrated a 60.5% reduction in procedure time (P < 0.0001). Although a trend toward improved centering accuracy was observed for Echo PS (16.2%), this was not significantly different than TS. Conclusions. Echo PS demonstrated a significant reduction in overall simulated LVHR procedure time, particularly during mesh preparation/positioning. These operative time savings may translate into reduced operating room costs and improved surgeon/operating room efficiency. |
format | Online Article Text |
id | pubmed-3676964 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-36769642013-06-12 Evaluation of ECHO PS Positioning System in a Porcine Model of Simulated Laparoscopic Ventral Hernia Repair Hanna, Erin M. Voeller, Guy R. Roth, J. Scott Scott, Jeffrey R. Gagne, Darcy H. Iannitti, David A. ISRN Surg Research Article Purpose. Operative efficiency improvements for laparoscopic ventral hernia repair (LVHR) have focused on reducing operative time while maintaining overall repair efficacy. Our objective was to evaluate procedure time and positioning accuracy of an inflatable mesh positioning device (Echo PS Positioning System), as compared to a standard transfascial suture technique, using a porcine model of simulated LVHR. Methods. The study population consisted of seventeen general surgeons (n = 17) that performed simulated LVHR on seventeen (n = 17) female Yorkshire pigs using two implantation techniques: (1) Ventralight ST Mesh + Echo PS Positioning System (Echo PS) and (2) Ventralight ST Mesh + transfascial sutures (TSs). Procedure time and mesh centering accuracy overtop of a simulated surgical defect were evaluated. Results. Echo PS demonstrated a 38.9% reduction in the overall procedure time, as compared to TS. During mesh preparation and positioning, Echo PS demonstrated a 60.5% reduction in procedure time (P < 0.0001). Although a trend toward improved centering accuracy was observed for Echo PS (16.2%), this was not significantly different than TS. Conclusions. Echo PS demonstrated a significant reduction in overall simulated LVHR procedure time, particularly during mesh preparation/positioning. These operative time savings may translate into reduced operating room costs and improved surgeon/operating room efficiency. Hindawi Publishing Corporation 2013-05-23 /pmc/articles/PMC3676964/ /pubmed/23762628 http://dx.doi.org/10.1155/2013/862549 Text en Copyright © 2013 Erin M. Hanna et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Hanna, Erin M. Voeller, Guy R. Roth, J. Scott Scott, Jeffrey R. Gagne, Darcy H. Iannitti, David A. Evaluation of ECHO PS Positioning System in a Porcine Model of Simulated Laparoscopic Ventral Hernia Repair |
title | Evaluation of ECHO PS Positioning System in a Porcine Model of Simulated Laparoscopic Ventral Hernia Repair |
title_full | Evaluation of ECHO PS Positioning System in a Porcine Model of Simulated Laparoscopic Ventral Hernia Repair |
title_fullStr | Evaluation of ECHO PS Positioning System in a Porcine Model of Simulated Laparoscopic Ventral Hernia Repair |
title_full_unstemmed | Evaluation of ECHO PS Positioning System in a Porcine Model of Simulated Laparoscopic Ventral Hernia Repair |
title_short | Evaluation of ECHO PS Positioning System in a Porcine Model of Simulated Laparoscopic Ventral Hernia Repair |
title_sort | evaluation of echo ps positioning system in a porcine model of simulated laparoscopic ventral hernia repair |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3676964/ https://www.ncbi.nlm.nih.gov/pubmed/23762628 http://dx.doi.org/10.1155/2013/862549 |
work_keys_str_mv | AT hannaerinm evaluationofechopspositioningsysteminaporcinemodelofsimulatedlaparoscopicventralherniarepair AT voellerguyr evaluationofechopspositioningsysteminaporcinemodelofsimulatedlaparoscopicventralherniarepair AT rothjscott evaluationofechopspositioningsysteminaporcinemodelofsimulatedlaparoscopicventralherniarepair AT scottjeffreyr evaluationofechopspositioningsysteminaporcinemodelofsimulatedlaparoscopicventralherniarepair AT gagnedarcyh evaluationofechopspositioningsysteminaporcinemodelofsimulatedlaparoscopicventralherniarepair AT iannittidavida evaluationofechopspositioningsysteminaporcinemodelofsimulatedlaparoscopicventralherniarepair |