Cargando…

Evaluation of ECHO PS Positioning System in a Porcine Model of Simulated Laparoscopic Ventral Hernia Repair

Purpose. Operative efficiency improvements for laparoscopic ventral hernia repair (LVHR) have focused on reducing operative time while maintaining overall repair efficacy. Our objective was to evaluate procedure time and positioning accuracy of an inflatable mesh positioning device (Echo PS Position...

Descripción completa

Detalles Bibliográficos
Autores principales: Hanna, Erin M., Voeller, Guy R., Roth, J. Scott, Scott, Jeffrey R., Gagne, Darcy H., Iannitti, David A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3676964/
https://www.ncbi.nlm.nih.gov/pubmed/23762628
http://dx.doi.org/10.1155/2013/862549
_version_ 1782272689858150400
author Hanna, Erin M.
Voeller, Guy R.
Roth, J. Scott
Scott, Jeffrey R.
Gagne, Darcy H.
Iannitti, David A.
author_facet Hanna, Erin M.
Voeller, Guy R.
Roth, J. Scott
Scott, Jeffrey R.
Gagne, Darcy H.
Iannitti, David A.
author_sort Hanna, Erin M.
collection PubMed
description Purpose. Operative efficiency improvements for laparoscopic ventral hernia repair (LVHR) have focused on reducing operative time while maintaining overall repair efficacy. Our objective was to evaluate procedure time and positioning accuracy of an inflatable mesh positioning device (Echo PS Positioning System), as compared to a standard transfascial suture technique, using a porcine model of simulated LVHR. Methods. The study population consisted of seventeen general surgeons (n = 17) that performed simulated LVHR on seventeen (n = 17) female Yorkshire pigs using two implantation techniques: (1) Ventralight ST Mesh + Echo PS Positioning System (Echo PS) and (2) Ventralight ST Mesh + transfascial sutures (TSs). Procedure time and mesh centering accuracy overtop of a simulated surgical defect were evaluated. Results. Echo PS demonstrated a 38.9% reduction in the overall procedure time, as compared to TS. During mesh preparation and positioning, Echo PS demonstrated a 60.5% reduction in procedure time (P < 0.0001). Although a trend toward improved centering accuracy was observed for Echo PS (16.2%), this was not significantly different than TS. Conclusions. Echo PS demonstrated a significant reduction in overall simulated LVHR procedure time, particularly during mesh preparation/positioning. These operative time savings may translate into reduced operating room costs and improved surgeon/operating room efficiency.
format Online
Article
Text
id pubmed-3676964
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-36769642013-06-12 Evaluation of ECHO PS Positioning System in a Porcine Model of Simulated Laparoscopic Ventral Hernia Repair Hanna, Erin M. Voeller, Guy R. Roth, J. Scott Scott, Jeffrey R. Gagne, Darcy H. Iannitti, David A. ISRN Surg Research Article Purpose. Operative efficiency improvements for laparoscopic ventral hernia repair (LVHR) have focused on reducing operative time while maintaining overall repair efficacy. Our objective was to evaluate procedure time and positioning accuracy of an inflatable mesh positioning device (Echo PS Positioning System), as compared to a standard transfascial suture technique, using a porcine model of simulated LVHR. Methods. The study population consisted of seventeen general surgeons (n = 17) that performed simulated LVHR on seventeen (n = 17) female Yorkshire pigs using two implantation techniques: (1) Ventralight ST Mesh + Echo PS Positioning System (Echo PS) and (2) Ventralight ST Mesh + transfascial sutures (TSs). Procedure time and mesh centering accuracy overtop of a simulated surgical defect were evaluated. Results. Echo PS demonstrated a 38.9% reduction in the overall procedure time, as compared to TS. During mesh preparation and positioning, Echo PS demonstrated a 60.5% reduction in procedure time (P < 0.0001). Although a trend toward improved centering accuracy was observed for Echo PS (16.2%), this was not significantly different than TS. Conclusions. Echo PS demonstrated a significant reduction in overall simulated LVHR procedure time, particularly during mesh preparation/positioning. These operative time savings may translate into reduced operating room costs and improved surgeon/operating room efficiency. Hindawi Publishing Corporation 2013-05-23 /pmc/articles/PMC3676964/ /pubmed/23762628 http://dx.doi.org/10.1155/2013/862549 Text en Copyright © 2013 Erin M. Hanna et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Hanna, Erin M.
Voeller, Guy R.
Roth, J. Scott
Scott, Jeffrey R.
Gagne, Darcy H.
Iannitti, David A.
Evaluation of ECHO PS Positioning System in a Porcine Model of Simulated Laparoscopic Ventral Hernia Repair
title Evaluation of ECHO PS Positioning System in a Porcine Model of Simulated Laparoscopic Ventral Hernia Repair
title_full Evaluation of ECHO PS Positioning System in a Porcine Model of Simulated Laparoscopic Ventral Hernia Repair
title_fullStr Evaluation of ECHO PS Positioning System in a Porcine Model of Simulated Laparoscopic Ventral Hernia Repair
title_full_unstemmed Evaluation of ECHO PS Positioning System in a Porcine Model of Simulated Laparoscopic Ventral Hernia Repair
title_short Evaluation of ECHO PS Positioning System in a Porcine Model of Simulated Laparoscopic Ventral Hernia Repair
title_sort evaluation of echo ps positioning system in a porcine model of simulated laparoscopic ventral hernia repair
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3676964/
https://www.ncbi.nlm.nih.gov/pubmed/23762628
http://dx.doi.org/10.1155/2013/862549
work_keys_str_mv AT hannaerinm evaluationofechopspositioningsysteminaporcinemodelofsimulatedlaparoscopicventralherniarepair
AT voellerguyr evaluationofechopspositioningsysteminaporcinemodelofsimulatedlaparoscopicventralherniarepair
AT rothjscott evaluationofechopspositioningsysteminaporcinemodelofsimulatedlaparoscopicventralherniarepair
AT scottjeffreyr evaluationofechopspositioningsysteminaporcinemodelofsimulatedlaparoscopicventralherniarepair
AT gagnedarcyh evaluationofechopspositioningsysteminaporcinemodelofsimulatedlaparoscopicventralherniarepair
AT iannittidavida evaluationofechopspositioningsysteminaporcinemodelofsimulatedlaparoscopicventralherniarepair