Cargando…
Parallel improvement of left ventricular geometry and filling pressure after transcatheter aortic valve implantation in high risk aortic stenosis: comparison with major prosthetic surgery by standard echo Doppler evaluation
PURPOSE: The effect of Transcatheter Aortic Valve Implantation (TAVI) on left ventricular (LV) geometry and function was compared to traditional aortic replacement (AVR) by major surgery. METHODS: 45 patients with aortic stenosis (AS) undergoing TAVI and 33 AVR were assessed by standard echo Doppler...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3679950/ https://www.ncbi.nlm.nih.gov/pubmed/23731705 http://dx.doi.org/10.1186/1476-7120-11-18 |
_version_ | 1782273043407568896 |
---|---|
author | Costantino, Marco Fabio Galderisi, Maurizio Dores, Ernesta Innelli, Pasquale Tarsia, Giandomenico Di Natale, Maurilio Santoro, Ciro De Stefano, Francesco Esposito, Roberta de Simone, Giovanni |
author_facet | Costantino, Marco Fabio Galderisi, Maurizio Dores, Ernesta Innelli, Pasquale Tarsia, Giandomenico Di Natale, Maurilio Santoro, Ciro De Stefano, Francesco Esposito, Roberta de Simone, Giovanni |
author_sort | Costantino, Marco Fabio |
collection | PubMed |
description | PURPOSE: The effect of Transcatheter Aortic Valve Implantation (TAVI) on left ventricular (LV) geometry and function was compared to traditional aortic replacement (AVR) by major surgery. METHODS: 45 patients with aortic stenosis (AS) undergoing TAVI and 33 AVR were assessed by standard echo Doppler the day before and 2 months after the implantation. 2D echocardiograms were performed to measure left ventricular (LV) mass index (LVMi), relative wall thickness (RWT), ejection fraction (EF) and the ratio between transmitral E velocity and early diastolic velocity of mitral annulus (E/e’ ratio). Valvular-arterial impedance (Zva) was also calculated. RESULTS: At baseline, the 2 groups were comparable for blood pressure, heart rate, body mass index mean transvalvular gradient and aortic valve area. TAVI patients were older (p<0.0001) and had greater LVMi (p<0.005) than AVR group. After 2 months, both the procedures induced a significant reduction of transvalvular gradient and Zva but the decrease of LVMi and RWT was significant greater after TAVI (both p<0.0001). E/e’ ratio and EF were significantly improved after both the procedure but E/e’ reduction was greater after TAVI (p<0.0001). TAVI exhibited greater percent reduction in mean transvalvular gradient (p<0.05), Zva (p<0.02), LVMi (p<0.0001), RWT (p<0.0001) and E/e’ ratio (p<0.0001) than AVR patients. Reduction of E/e’ ratio was positively related with reduction of RWT (r = 0.46, p<0.002) only in TAVI group, even after adjusting for age and percent reduction of Zva (r =0.43, p<0.005). CONCLUSIONS: TAVI induces a greater improvement of estimated LV filling pressure in comparison with major prosthetic surgery, due to more pronounced recovery of LV geometry, independent on age and changes of hemodynamic load. |
format | Online Article Text |
id | pubmed-3679950 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-36799502013-06-13 Parallel improvement of left ventricular geometry and filling pressure after transcatheter aortic valve implantation in high risk aortic stenosis: comparison with major prosthetic surgery by standard echo Doppler evaluation Costantino, Marco Fabio Galderisi, Maurizio Dores, Ernesta Innelli, Pasquale Tarsia, Giandomenico Di Natale, Maurilio Santoro, Ciro De Stefano, Francesco Esposito, Roberta de Simone, Giovanni Cardiovasc Ultrasound Research PURPOSE: The effect of Transcatheter Aortic Valve Implantation (TAVI) on left ventricular (LV) geometry and function was compared to traditional aortic replacement (AVR) by major surgery. METHODS: 45 patients with aortic stenosis (AS) undergoing TAVI and 33 AVR were assessed by standard echo Doppler the day before and 2 months after the implantation. 2D echocardiograms were performed to measure left ventricular (LV) mass index (LVMi), relative wall thickness (RWT), ejection fraction (EF) and the ratio between transmitral E velocity and early diastolic velocity of mitral annulus (E/e’ ratio). Valvular-arterial impedance (Zva) was also calculated. RESULTS: At baseline, the 2 groups were comparable for blood pressure, heart rate, body mass index mean transvalvular gradient and aortic valve area. TAVI patients were older (p<0.0001) and had greater LVMi (p<0.005) than AVR group. After 2 months, both the procedures induced a significant reduction of transvalvular gradient and Zva but the decrease of LVMi and RWT was significant greater after TAVI (both p<0.0001). E/e’ ratio and EF were significantly improved after both the procedure but E/e’ reduction was greater after TAVI (p<0.0001). TAVI exhibited greater percent reduction in mean transvalvular gradient (p<0.05), Zva (p<0.02), LVMi (p<0.0001), RWT (p<0.0001) and E/e’ ratio (p<0.0001) than AVR patients. Reduction of E/e’ ratio was positively related with reduction of RWT (r = 0.46, p<0.002) only in TAVI group, even after adjusting for age and percent reduction of Zva (r =0.43, p<0.005). CONCLUSIONS: TAVI induces a greater improvement of estimated LV filling pressure in comparison with major prosthetic surgery, due to more pronounced recovery of LV geometry, independent on age and changes of hemodynamic load. BioMed Central 2013-06-03 /pmc/articles/PMC3679950/ /pubmed/23731705 http://dx.doi.org/10.1186/1476-7120-11-18 Text en Copyright © 2013 Costantino et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Costantino, Marco Fabio Galderisi, Maurizio Dores, Ernesta Innelli, Pasquale Tarsia, Giandomenico Di Natale, Maurilio Santoro, Ciro De Stefano, Francesco Esposito, Roberta de Simone, Giovanni Parallel improvement of left ventricular geometry and filling pressure after transcatheter aortic valve implantation in high risk aortic stenosis: comparison with major prosthetic surgery by standard echo Doppler evaluation |
title | Parallel improvement of left ventricular geometry and filling pressure after transcatheter aortic valve implantation in high risk aortic stenosis: comparison with major prosthetic surgery by standard echo Doppler evaluation |
title_full | Parallel improvement of left ventricular geometry and filling pressure after transcatheter aortic valve implantation in high risk aortic stenosis: comparison with major prosthetic surgery by standard echo Doppler evaluation |
title_fullStr | Parallel improvement of left ventricular geometry and filling pressure after transcatheter aortic valve implantation in high risk aortic stenosis: comparison with major prosthetic surgery by standard echo Doppler evaluation |
title_full_unstemmed | Parallel improvement of left ventricular geometry and filling pressure after transcatheter aortic valve implantation in high risk aortic stenosis: comparison with major prosthetic surgery by standard echo Doppler evaluation |
title_short | Parallel improvement of left ventricular geometry and filling pressure after transcatheter aortic valve implantation in high risk aortic stenosis: comparison with major prosthetic surgery by standard echo Doppler evaluation |
title_sort | parallel improvement of left ventricular geometry and filling pressure after transcatheter aortic valve implantation in high risk aortic stenosis: comparison with major prosthetic surgery by standard echo doppler evaluation |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3679950/ https://www.ncbi.nlm.nih.gov/pubmed/23731705 http://dx.doi.org/10.1186/1476-7120-11-18 |
work_keys_str_mv | AT costantinomarcofabio parallelimprovementofleftventriculargeometryandfillingpressureaftertranscatheteraorticvalveimplantationinhighriskaorticstenosiscomparisonwithmajorprostheticsurgerybystandardechodopplerevaluation AT galderisimaurizio parallelimprovementofleftventriculargeometryandfillingpressureaftertranscatheteraorticvalveimplantationinhighriskaorticstenosiscomparisonwithmajorprostheticsurgerybystandardechodopplerevaluation AT doresernesta parallelimprovementofleftventriculargeometryandfillingpressureaftertranscatheteraorticvalveimplantationinhighriskaorticstenosiscomparisonwithmajorprostheticsurgerybystandardechodopplerevaluation AT innellipasquale parallelimprovementofleftventriculargeometryandfillingpressureaftertranscatheteraorticvalveimplantationinhighriskaorticstenosiscomparisonwithmajorprostheticsurgerybystandardechodopplerevaluation AT tarsiagiandomenico parallelimprovementofleftventriculargeometryandfillingpressureaftertranscatheteraorticvalveimplantationinhighriskaorticstenosiscomparisonwithmajorprostheticsurgerybystandardechodopplerevaluation AT dinatalemaurilio parallelimprovementofleftventriculargeometryandfillingpressureaftertranscatheteraorticvalveimplantationinhighriskaorticstenosiscomparisonwithmajorprostheticsurgerybystandardechodopplerevaluation AT santorociro parallelimprovementofleftventriculargeometryandfillingpressureaftertranscatheteraorticvalveimplantationinhighriskaorticstenosiscomparisonwithmajorprostheticsurgerybystandardechodopplerevaluation AT destefanofrancesco parallelimprovementofleftventriculargeometryandfillingpressureaftertranscatheteraorticvalveimplantationinhighriskaorticstenosiscomparisonwithmajorprostheticsurgerybystandardechodopplerevaluation AT espositoroberta parallelimprovementofleftventriculargeometryandfillingpressureaftertranscatheteraorticvalveimplantationinhighriskaorticstenosiscomparisonwithmajorprostheticsurgerybystandardechodopplerevaluation AT desimonegiovanni parallelimprovementofleftventriculargeometryandfillingpressureaftertranscatheteraorticvalveimplantationinhighriskaorticstenosiscomparisonwithmajorprostheticsurgerybystandardechodopplerevaluation |